Lorusso, Roberto - Abstract:
- Abstract: Background: Thrombocytopenia has been shown to occur soon after surgical biological aortic valve replacement (AVR), and recently reported also after transcatheter valve implantation (TAVI). The mechanism underlying this phenomenon is still unknown, and its clinical impact on the peri-operative outcome has been poorly investigated. Methods: A systematic review and a meta-analysis of all available studies reporting data about peri-procedural thrombocytopenia on isolated bio-AVR, comparing rapid-deployment (RDV), stentless (stentless-AVR), and TAVI vs. stented (stented-AVR) valves, have been performed. Results: Fifteen trials (2.163 patients) were included in the meta-analysis. Perioperative platelet reduction ranged from 35% to 55% in stented-AVR, from 60% to 77% in stentless-AVR, from 53% to 60% in RDV, and from to 21% to 72% in TAVI (apparently, balloon-expandable valves more frequently associated to thrombocytopenia). Stented-AVR required more red blood cells transfusion than stentless-AVR ( P < 0.0001), whereas no difference has been found between RDV and stented-AVR. Platelet transfusion rate was very low in all surgical groups. No difference has been found in RDV and stentless-AVR vs. stented-AVR, in terms of reoperation for bleeding, and length-of-intensive care unit or hospital stay. Conclusions: Thrombocytopenia-related major adverse events were mainly reported in TAVI patients, whereas clinically meaningless in surgical patients. Transient peri-proceduralAbstract: Background: Thrombocytopenia has been shown to occur soon after surgical biological aortic valve replacement (AVR), and recently reported also after transcatheter valve implantation (TAVI). The mechanism underlying this phenomenon is still unknown, and its clinical impact on the peri-operative outcome has been poorly investigated. Methods: A systematic review and a meta-analysis of all available studies reporting data about peri-procedural thrombocytopenia on isolated bio-AVR, comparing rapid-deployment (RDV), stentless (stentless-AVR), and TAVI vs. stented (stented-AVR) valves, have been performed. Results: Fifteen trials (2.163 patients) were included in the meta-analysis. Perioperative platelet reduction ranged from 35% to 55% in stented-AVR, from 60% to 77% in stentless-AVR, from 53% to 60% in RDV, and from to 21% to 72% in TAVI (apparently, balloon-expandable valves more frequently associated to thrombocytopenia). Stented-AVR required more red blood cells transfusion than stentless-AVR ( P < 0.0001), whereas no difference has been found between RDV and stented-AVR. Platelet transfusion rate was very low in all surgical groups. No difference has been found in RDV and stentless-AVR vs. stented-AVR, in terms of reoperation for bleeding, and length-of-intensive care unit or hospital stay. Conclusions: Thrombocytopenia-related major adverse events were mainly reported in TAVI patients, whereas clinically meaningless in surgical patients. Transient peri-procedural thrombocytopenia is common after bio-AVR, regardless of prosthesis's type or implant modality. It should receive appropriate monitoring and focused investigations. Highlights: Thrombocytopenia has been reported after surgical biological aortic valve replacement. Perioperative thrombocytopenia is often a transient event. Thrombocytopenia may occur also in trans-catheter aortic valve implantation patients. Patients receiving balloon-expandable valves seem more prone to develop thrombocytopenia. Thrombocytopenia is not a subclinical event, but it could impact patients' postoperative course. … (more)
- Is Part Of:
- International journal of cardiology. Volume 296(2019)
- Journal:
- International journal of cardiology
- Issue:
- Volume 296(2019)
- Issue Display:
- Volume 296, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 296
- Issue:
- 2019
- Issue Sort Value:
- 2019-0296-2019-0000
- Page Start:
- 43
- Page End:
- 50
- Publication Date:
- 2019-12-01
- Subjects:
- Platelet -- Thrombocytopenia -- Aortic valve replacement -- Trans-catheter aortic valve implantation -- Bleeding
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2019.07.056 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11834.xml