First measurements with a plastic scintillation dosimeter at the Australian MRI-LINAC. (4th September 2019)
- Record Type:
- Journal Article
- Title:
- First measurements with a plastic scintillation dosimeter at the Australian MRI-LINAC. (4th September 2019)
- Main Title:
- First measurements with a plastic scintillation dosimeter at the Australian MRI-LINAC
- Authors:
- Madden, Levi
Archer, James
Li, Enbang
Jelen, Urszula
Dong, Bin
Roberts, Natalia
Holloway, Lois
Rosenfeld, Anatoly - Abstract:
- Abstract: MRI-LINACs combine MRI and LINAC technologies with the potential for image guided radiation therapy with optimal soft-tissue contrast. In this work, we present the advantages and limitations of plastic scintillation dosimeters (PSDs) for relative dosimetry with MRI-LINACs. PSDs possess many desirable qualities, including magnetic field insensitivity and irradiation angle independence, which are expected to make them suitable for dosimetry with MRI-LINACs. An in-house PSD was used to measure field size output factors as well as a percent depth dose distribution and the beam quality index TPR20/10 at a cm 2 field size. Measurements were repeated with a Scanditronix/Wellhofer FC65-G ionisation chamber and PTW 60019 microDiamond detector for comparison. Relative differences were calculated between the three detectors, where the mean difference in dose was 1.2% between the PSD and ionisation chamber, 1.9% between the PSD and microDiamond detector and 1.3% between the microDiamond detector and the ionisation chamber. The closeness between the three mean differences in doses suggests that PSDs are feasible for relative dosimetry with MRI-LINACs.
- Is Part Of:
- Physics in medicine & biology. Volume 64:Number 17(2019:Sep.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 64:Number 17(2019:Sep.)
- Issue Display:
- Volume 64, Issue 17 (2019)
- Year:
- 2019
- Volume:
- 64
- Issue:
- 17
- Issue Sort Value:
- 2019-0064-0017-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-09-04
- Subjects:
- MRI-LINAC -- fiber optic dosimeter -- plastic scintillator -- dosimetry
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/ab324b ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11836.xml