Three-year major clinical outcomes of phosphorylcholine polymer- vs biolinx polymer-zotarolimus-eluting stents: A propensity score matching study. Issue 32 (August 2019)
- Record Type:
- Journal Article
- Title:
- Three-year major clinical outcomes of phosphorylcholine polymer- vs biolinx polymer-zotarolimus-eluting stents: A propensity score matching study. Issue 32 (August 2019)
- Main Title:
- Three-year major clinical outcomes of phosphorylcholine polymer- vs biolinx polymer-zotarolimus-eluting stents
- Authors:
- Kim, Yong Hoon
Her, Ae-Young
Rha, Seung-Woon
Choi, Byoung Geol
Choi, Se Yeon
Byun, Jae Kyeong
Park, Yoonjee
Kang, Dong Oh
Jang, Won Young
Kim, Woohyeun
Choi, Woong Gil
Kang, Tae Soo
Ahn, Jihun
Park, Sang-Ho
Park, Ji Young
Lee, Min-Ho
Choi, Cheol Ung
Park, Chang Gyu
Seo, Hong Seog - Other Names:
- Roever. Leonardo section editor.
- Abstract:
- Abstract : Abstract: There are limited long-term outcome data comparing BioLinx polymer (B)-zotarolimus-eluting stents (ZES) with phosphorylcholine polymer (P)-ZES. The aim of this study was to compare the efficacy and safety of B-ZES with P-ZES in patients who underwent percutaneous coronary intervention (PCI) during a 3-year follow-up period. One thousand two hundred fifty four patients who underwent PCI with P-ZES (Endeavor [ZES-E] or Endeavor sprint [ZES-S], n = 356) or B-ZES (Endeavor resolute [ZES-R] or Resolute Integrity [ZES-I], n = 889) were enrolled. The primary endpoint was major adverse cardiac events (MACE); the composite of total death, non-fatal myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), non-target vessel revascularization (Non-TVR), and the secondary endpoint was stent thrombosis (ST). After PSM, 2 propensity-matched (PSM) groups (275 pairs, n = 550, C-statistic = 0.730) were generated. During the 3-year follow-up period, the cumulative incidence of MACE (hazard ratio [HR], 1.525; 95% confidence interval [CI], 0.920–2.526; P = .101) and ST (HR, 1.248; 95% CI, 0.335–4.4649; P = .741) were similar between P-ZES and B-ZES after PSM. However, TLR rate was significantly higher in ZES-S than ZES-I (11.3% vs 3.8%, log rank P = .029) and TVR rate was higher in ZES-S than ZES-R (14.1% vs 4.8%, log rank P = .025). In this single-center, all-comer registry, despite different polymers, P-ZES, and B-ZESAbstract : Abstract: There are limited long-term outcome data comparing BioLinx polymer (B)-zotarolimus-eluting stents (ZES) with phosphorylcholine polymer (P)-ZES. The aim of this study was to compare the efficacy and safety of B-ZES with P-ZES in patients who underwent percutaneous coronary intervention (PCI) during a 3-year follow-up period. One thousand two hundred fifty four patients who underwent PCI with P-ZES (Endeavor [ZES-E] or Endeavor sprint [ZES-S], n = 356) or B-ZES (Endeavor resolute [ZES-R] or Resolute Integrity [ZES-I], n = 889) were enrolled. The primary endpoint was major adverse cardiac events (MACE); the composite of total death, non-fatal myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), non-target vessel revascularization (Non-TVR), and the secondary endpoint was stent thrombosis (ST). After PSM, 2 propensity-matched (PSM) groups (275 pairs, n = 550, C-statistic = 0.730) were generated. During the 3-year follow-up period, the cumulative incidence of MACE (hazard ratio [HR], 1.525; 95% confidence interval [CI], 0.920–2.526; P = .101) and ST (HR, 1.248; 95% CI, 0.335–4.4649; P = .741) were similar between P-ZES and B-ZES after PSM. However, TLR rate was significantly higher in ZES-S than ZES-I (11.3% vs 3.8%, log rank P = .029) and TVR rate was higher in ZES-S than ZES-R (14.1% vs 4.8%, log rank P = .025). In this single-center, all-comer registry, despite different polymers, P-ZES, and B-ZES showed comparable safety and efficacy during a 3-year follow-up period after PCI. Abstract : Supplemental Digital Content is available in the text … (more)
- Is Part Of:
- Medicine. Volume 98:Issue 32(2019)
- Journal:
- Medicine
- Issue:
- Volume 98:Issue 32(2019)
- Issue Display:
- Volume 98, Issue 32 (2019)
- Year:
- 2019
- Volume:
- 98
- Issue:
- 32
- Issue Sort Value:
- 2019-0098-0032-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-08
- Subjects:
- BioLinx -- clinical outcomes -- drug-eluting stent -- phoshorylcholine -- Polymer -- Zotarolimus
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000016767 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11841.xml