Development and Validation of a Fast Ultra-High Performance Liquid Chromatography–Fluorescent Method for the Quantification of Hydroxychloroquine and Its Metabolites in Patients With Lupus. Issue 4 (August 2019)
- Record Type:
- Journal Article
- Title:
- Development and Validation of a Fast Ultra-High Performance Liquid Chromatography–Fluorescent Method for the Quantification of Hydroxychloroquine and Its Metabolites in Patients With Lupus. Issue 4 (August 2019)
- Main Title:
- Development and Validation of a Fast Ultra-High Performance Liquid Chromatography–Fluorescent Method for the Quantification of Hydroxychloroquine and Its Metabolites in Patients With Lupus
- Authors:
- Noé, Gaëlle
Amoura, Zahir
Combarel, David
Lori, Lesli
Tissot, Nadine
Seycha, Aguila
Funck-Brentano, Christian
Zahr, Noël - Abstract:
- Abstract : Background: Hydroxychloroquine (HCQ) is approved for the treatment of systemic lupus erythematosus (SLE). Therapeutic drug monitoring of HCQ is necessary to detect nonadherence and to improve treatment efficacy in patients with SLE. Liquid chromatographic–tandem mass spectroscopy and high performance liquid chromatography (HPLC)–fluorescent methods are currently used to measure whole blood concentrations of HCQ and its 2 main metabolites desethylhydroxychloroquine and desethylchloroquine in patients with SLE. This study reports the development and validation of an ultra-HPLC (U-HPLC) method with fluorescence detection for the simultaneous quantification of HCQ and its metabolites in whole blood. Methods: After adding chloroquine (internal standard) to the samples, a single-step protein precipitation and a subsequent filtration were used for blood sample preparation. Analytes were separated under isocratic elution on a U-HPLC RP18 column with a total run time of 7 minutes. The mobile phase consisted of piperazine buffer (46.4 mM, pH = 9.8) and acetonitrile (68:32, vol/vol), which was delivered at a flow rate of 0.4 mL/min. Fluorescence excitation and emission wavelengths were 335 and 390 nm, respectively. Assay performance parameters were evaluated per FDA bioanalytical guidelines. Results: The calibration curve was linear from 125 to 4000 ng/mL for HCQ. The lower limit of quantification was 10 ng/mL for all analytes. For HCQ, desethylchloroquine, andAbstract : Background: Hydroxychloroquine (HCQ) is approved for the treatment of systemic lupus erythematosus (SLE). Therapeutic drug monitoring of HCQ is necessary to detect nonadherence and to improve treatment efficacy in patients with SLE. Liquid chromatographic–tandem mass spectroscopy and high performance liquid chromatography (HPLC)–fluorescent methods are currently used to measure whole blood concentrations of HCQ and its 2 main metabolites desethylhydroxychloroquine and desethylchloroquine in patients with SLE. This study reports the development and validation of an ultra-HPLC (U-HPLC) method with fluorescence detection for the simultaneous quantification of HCQ and its metabolites in whole blood. Methods: After adding chloroquine (internal standard) to the samples, a single-step protein precipitation and a subsequent filtration were used for blood sample preparation. Analytes were separated under isocratic elution on a U-HPLC RP18 column with a total run time of 7 minutes. The mobile phase consisted of piperazine buffer (46.4 mM, pH = 9.8) and acetonitrile (68:32, vol/vol), which was delivered at a flow rate of 0.4 mL/min. Fluorescence excitation and emission wavelengths were 335 and 390 nm, respectively. Assay performance parameters were evaluated per FDA bioanalytical guidelines. Results: The calibration curve was linear from 125 to 4000 ng/mL for HCQ. The lower limit of quantification was 10 ng/mL for all analytes. For HCQ, desethylchloroquine, and desethylhydroxychloroquine, accuracies and imprecisions ranged from −7.90% to 7.85% and 1.14% to 8.78%, respectively. Conclusions: A sensitive, accurate, and fast U-HPLC–fluorescent method was validated and successfully applied to quantify whole blood concentrations to perform therapeutic drug monitoring of HCQ in pediatric and adult lupus patients. … (more)
- Is Part Of:
- Therapeutic drug monitoring. Volume 41:Issue 4(2019:Aug.)
- Journal:
- Therapeutic drug monitoring
- Issue:
- Volume 41:Issue 4(2019:Aug.)
- Issue Display:
- Volume 41, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 41
- Issue:
- 4
- Issue Sort Value:
- 2019-0041-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-08
- Subjects:
- hydroxychloroquine -- U-HPLC -- lupus -- TDM
Pharmacokinetics -- Periodicals
Patient monitoring -- Periodicals
Drugs -- Analysis -- Periodicals
Body fluids -- Analysis -- Periodicals
Drug Therapy -- Periodicals
Monitoring, Physiologic -- Periodicals
Pharmacology -- Periodicals
615.7 - Journal URLs:
- http://journals.lww.com/drug-monitoring/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00007691-000000000-00000 ↗
http://www.drug-monitoring.com/ ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0163-4356 ↗ - DOI:
- 10.1097/FTD.0000000000000614 ↗
- Languages:
- English
- ISSNs:
- 0163-4356
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8814.643000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11832.xml