Effect of Continuous-Flow Left Ventricular Assist Device Support on Coronary Artery Endothelial Function in Ischemic and Nonischemic Cardiomyopathy. (August 2019)
- Record Type:
- Journal Article
- Title:
- Effect of Continuous-Flow Left Ventricular Assist Device Support on Coronary Artery Endothelial Function in Ischemic and Nonischemic Cardiomyopathy. (August 2019)
- Main Title:
- Effect of Continuous-Flow Left Ventricular Assist Device Support on Coronary Artery Endothelial Function in Ischemic and Nonischemic Cardiomyopathy
- Authors:
- Symons, J. David
Deeter, Lance
Deeter, Nicholas
Bonn, Trevor
Cho, Jae Min
Ferrin, Peter
McCreath, Lauren
Diakos, Nikolaos A.
Taleb, Iosif
Alharethi, Rami
McKellar, Stephen
Wever-Pinzon, Omar
Navankasattusas, Sutip
Selzman, Craig H.
Fang, James C.
Drakos, Stavros G. - Abstract:
- Abstract : Background: The coronary vasculature encounters a reduction in pulsatility after implementing durable continuous-flow left ventricular assist device (CF-LVAD) circulatory support. Evidence exists that appropriate pulsatility is required to maintain endothelial cell homeostasis. We hypothesized that coronary artery endothelial function would be impaired after CF-LVAD intervention. Methods and Results: Coronary arteries from patients with end-stage heart failure caused by ischemic cardiomyopathy (ICM; n=16) or non-ICM (n=22) cardiomyopathy were isolated from the left ventricular apical core, which was removed for the CF-LVAD implantation. In 11 of these patients, paired coronary arteries were obtained from an adjacent region of myocardium after the CF-LVAD intervention (n=6 ICM, 5 non-ICM). Vascular function was assessed ex vivo using isometric tension procedures in these patients and in 7 nonfailing donor controls. Maximal endothelium-dependent vasorelaxation to BK (bradykinin; 10 − 6 –10 − 10 M) was blunted ( P <0.05) in arteries from patients with ICM compared with non-ICM and donor controls, whereas responses to sodium nitroprusside (10 −4 –10 −9 M) were similar among the groups. Contrary to our hypothesis, vasorelaxation responses to BK and sodium nitroprusside were similar before and 219±37 days after CF-LVAD support. Of these patients, an exploratory subgroup analysis revealed that BK-induced coronary artery vasorelaxation was greater ( P <0.05) after (87±6%)Abstract : Background: The coronary vasculature encounters a reduction in pulsatility after implementing durable continuous-flow left ventricular assist device (CF-LVAD) circulatory support. Evidence exists that appropriate pulsatility is required to maintain endothelial cell homeostasis. We hypothesized that coronary artery endothelial function would be impaired after CF-LVAD intervention. Methods and Results: Coronary arteries from patients with end-stage heart failure caused by ischemic cardiomyopathy (ICM; n=16) or non-ICM (n=22) cardiomyopathy were isolated from the left ventricular apical core, which was removed for the CF-LVAD implantation. In 11 of these patients, paired coronary arteries were obtained from an adjacent region of myocardium after the CF-LVAD intervention (n=6 ICM, 5 non-ICM). Vascular function was assessed ex vivo using isometric tension procedures in these patients and in 7 nonfailing donor controls. Maximal endothelium-dependent vasorelaxation to BK (bradykinin; 10 − 6 –10 − 10 M) was blunted ( P <0.05) in arteries from patients with ICM compared with non-ICM and donor controls, whereas responses to sodium nitroprusside (10 −4 –10 −9 M) were similar among the groups. Contrary to our hypothesis, vasorelaxation responses to BK and sodium nitroprusside were similar before and 219±37 days after CF-LVAD support. Of these patients, an exploratory subgroup analysis revealed that BK-induced coronary artery vasorelaxation was greater ( P <0.05) after (87±6%) versus before (54±14%) CF-LVAD intervention in ICM patients, whereas sodium nitroprusside–evoked responses were similar. Conclusions: Coronary artery endothelial function is not impaired by durable CF-LVAD support and in ICM patients appears to be improved. Investigating coronary endothelial function using in vivo approaches in a larger patient population is warranted. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 12:Number 8(2019)
- Journal:
- Circulation
- Issue:
- Volume 12:Number 8(2019)
- Issue Display:
- Volume 12, Issue 8 (2019)
- Year:
- 2019
- Volume:
- 12
- Issue:
- 8
- Issue Sort Value:
- 2019-0012-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-08
- Subjects:
- arteries -- endothelium -- heart -- heart failure -- left ventricular assist device
Heart failure -- Periodicals
616.129005 - Journal URLs:
- http://circheartfailure.ahajournals.org/content/current ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCHEARTFAILURE.119.006085 ↗
- Languages:
- English
- ISSNs:
- 1941-3289
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.282000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11835.xml