The Inadequate Oxygen Delivery Index and Low Cardiac Output Syndrome Score As Predictors of Adverse Events Associated With Low Cardiac Output Syndrome Early After Cardiac Bypass*. Issue 8 (August 2019)
- Record Type:
- Journal Article
- Title:
- The Inadequate Oxygen Delivery Index and Low Cardiac Output Syndrome Score As Predictors of Adverse Events Associated With Low Cardiac Output Syndrome Early After Cardiac Bypass*. Issue 8 (August 2019)
- Main Title:
- The Inadequate Oxygen Delivery Index and Low Cardiac Output Syndrome Score As Predictors of Adverse Events Associated With Low Cardiac Output Syndrome Early After Cardiac Bypass*
- Authors:
- Rogers, Libby
Ray, Samiran
Johnson, Mae
Feinstein, Yael
Dominguez, Troy E.
Peters, Mark J.
Hoskote, Aparna
Brown, Katherine L. - Abstract:
- Abstract : Objectives: To evaluate the effectiveness of two scoring systems, the inadequate oxygen delivery index, a risk analytics algorithm (Etiometry, Boston, MA) and the Low Cardiac Output Syndrome Score, in predicting adverse events recognized as indicative of low cardiac output syndrome within 72 hours of surgery. Design: A retrospective observational pair-matched study. Setting: Tertiary pediatric cardiac ICU. Patients: Children undergoing cardiac bypass for congenital heart defects. Cases experienced an adverse event linked to low cardiac output syndrome in the 72 hours following surgery (extracorporeal membrane oxygenation, renal replacement therapy, cardiopulmonary resuscitation, and necrotizing enterocolitis) and were matched with a control patient on criteria of procedure, diagnosis, and age who experienced no such event. Interventions: None. Measurements and Main Results: Of a total 536 bypass operations in the study period, 38 patients experienced one of the defined events. Twenty-eight cases were included in the study after removing patients who suffered an event after 72 hours or who had insufficient data. Clinical and laboratory data were collected to derive scores for the first 12 hours after surgery. The inadequate oxygen delivery index was calculated by Etiometry using vital signs and laboratory data. A modified Low Cardiac Output Syndrome Score was calculated from clinical and therapeutic markers. The mean inadequate oxygen delivery and modified LowAbstract : Objectives: To evaluate the effectiveness of two scoring systems, the inadequate oxygen delivery index, a risk analytics algorithm (Etiometry, Boston, MA) and the Low Cardiac Output Syndrome Score, in predicting adverse events recognized as indicative of low cardiac output syndrome within 72 hours of surgery. Design: A retrospective observational pair-matched study. Setting: Tertiary pediatric cardiac ICU. Patients: Children undergoing cardiac bypass for congenital heart defects. Cases experienced an adverse event linked to low cardiac output syndrome in the 72 hours following surgery (extracorporeal membrane oxygenation, renal replacement therapy, cardiopulmonary resuscitation, and necrotizing enterocolitis) and were matched with a control patient on criteria of procedure, diagnosis, and age who experienced no such event. Interventions: None. Measurements and Main Results: Of a total 536 bypass operations in the study period, 38 patients experienced one of the defined events. Twenty-eight cases were included in the study after removing patients who suffered an event after 72 hours or who had insufficient data. Clinical and laboratory data were collected to derive scores for the first 12 hours after surgery. The inadequate oxygen delivery index was calculated by Etiometry using vital signs and laboratory data. A modified Low Cardiac Output Syndrome Score was calculated from clinical and therapeutic markers. The mean inadequate oxygen delivery and modified Low Cardiac Output Syndrome Score were compared within each matched pair using the Wilcoxon signed-rank test. Inadequate oxygen delivery correctly differentiated adverse events in 13 of 28 matched pairs, with no evidence of inadequate oxygen delivery being higher in cases ( p = 0.71). Modified Low Cardiac Output Syndrome Score correctly differentiated adverse events in 23 of 28 matched pairs, with strong evidence of a raised score in low cardiac output syndrome cases ( p < 0.01). Conclusions: Although inadequate oxygen delivery is an Food and Drug Administration approved indicator of risk for low mixed venous oxygen saturation, early postoperative average values were not linked with medium-term adverse events. The indicators included in the modified Low Cardiac Output Syndrome Score had a much stronger association with the specified adverse events. … (more)
- Is Part Of:
- Pediatric critical care medicine. Volume 20:Issue 8(2019)
- Journal:
- Pediatric critical care medicine
- Issue:
- Volume 20:Issue 8(2019)
- Issue Display:
- Volume 20, Issue 8 (2019)
- Year:
- 2019
- Volume:
- 20
- Issue:
- 8
- Issue Sort Value:
- 2019-0020-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-08
- Subjects:
- cardiac surgery -- low cardiac output syndrome -- morbidity -- pediatric -- physiologic monitoring
Pediatric intensive care -- Periodicals
Pediatric emergencies -- Periodicals
618.05 - Journal URLs:
- http://www.mdconsult.com/public/search?search_type=journal&j_sort=pub_date&j_issn=1529-7535 ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00130478-000000000-00000 ↗
http://journals.lww.com/pccmjournal/pages/default.aspx ↗
http://www.mdconsult.com/about/journallist/192093418-5/about0041.html ↗
http://www.pccmjournal.com/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/PCC.0000000000001960 ↗
- Languages:
- English
- ISSNs:
- 1529-7535
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6417.565000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11838.xml