Prospective, randomized trial of bioresorbable scaffolds vs. everolimus-eluting stents in patients undergoing coronary stenting for myocardial infarction: the Intracoronary Scaffold Assessment a Randomized evaluation of Absorb in Myocardial Infarction (ISAR-Absorb MI) trial. (5th December 2018)
- Record Type:
- Journal Article
- Title:
- Prospective, randomized trial of bioresorbable scaffolds vs. everolimus-eluting stents in patients undergoing coronary stenting for myocardial infarction: the Intracoronary Scaffold Assessment a Randomized evaluation of Absorb in Myocardial Infarction (ISAR-Absorb MI) trial. (5th December 2018)
- Main Title:
- Prospective, randomized trial of bioresorbable scaffolds vs. everolimus-eluting stents in patients undergoing coronary stenting for myocardial infarction: the Intracoronary Scaffold Assessment a Randomized evaluation of Absorb in Myocardial Infarction (ISAR-Absorb MI) trial
- Authors:
- Byrne, Robert A
Alfonso, Fernando
Schneider, Simon
Maeng, Michael
Wiebe, Jens
Kretov, Evgeny
Bradaric, Christian
Rai, Himanshu
Cuesta, Javier
Rivero, Fernando
Hoppmann, Petra
Schlichtenmaier, Jana
Christiansen, Evald H
Cassese, Salvatore
Joner, Michael
Schunkert, Heribert
Laugwitz, Karl-Ludwig
Kastrati, Adnan - Abstract:
- Abstract: Aims: Bioresorbable scaffolds (BRS) provide short-term coronary artery scaffolding and drug delivery. Although prior trials showed a higher rate of device failure compared with conventional drug-eluting stents (DES), only a single trial investigated patients undergoing percutaneous coronary intervention (PCI) for acute myocardial infarction (MI). We aimed to compare outcomes with BRS vs. DES in patients undergoing PCI for MI. Methods and results: We did a prospective, randomized, multicentre, non-inferiority, clinical trial of everolimus-eluting BRS vs. durable polymer everolimus-eluting stents (EES) in patients with acute MI. Patients were eligible for enrolment if they presented with ST-elevation MI, or non-ST-elevation MI with thrombosis visual at angiography and were randomly allocated to treatment with BRS or EES in 2:1 proportion. Angiographic follow-up was scheduled at 6–8 months and clinical follow-up was done at 12 months. The primary endpoint was percentage diameter stenosis in-segment at follow-up. A total of 262 patients were enrolled and were allocated to BRS ( n = 173) or EES ( n = 89). Angiographic follow-up was available for 213 (81.3%) patients. Mean diameter stenosis was 24.6 ± 12.2% with BRS vs. 27.3 ± 11.7% with EES (mean difference −2.7%, upper limit of one-sided 97.5% confidence limit 0.7%, pre-specified margin of non-inferiority 5%, P non-inferiority <0.001). The rate of the device-oriented composite of cardiac death/target vessel MI/targetAbstract: Aims: Bioresorbable scaffolds (BRS) provide short-term coronary artery scaffolding and drug delivery. Although prior trials showed a higher rate of device failure compared with conventional drug-eluting stents (DES), only a single trial investigated patients undergoing percutaneous coronary intervention (PCI) for acute myocardial infarction (MI). We aimed to compare outcomes with BRS vs. DES in patients undergoing PCI for MI. Methods and results: We did a prospective, randomized, multicentre, non-inferiority, clinical trial of everolimus-eluting BRS vs. durable polymer everolimus-eluting stents (EES) in patients with acute MI. Patients were eligible for enrolment if they presented with ST-elevation MI, or non-ST-elevation MI with thrombosis visual at angiography and were randomly allocated to treatment with BRS or EES in 2:1 proportion. Angiographic follow-up was scheduled at 6–8 months and clinical follow-up was done at 12 months. The primary endpoint was percentage diameter stenosis in-segment at follow-up. A total of 262 patients were enrolled and were allocated to BRS ( n = 173) or EES ( n = 89). Angiographic follow-up was available for 213 (81.3%) patients. Mean diameter stenosis was 24.6 ± 12.2% with BRS vs. 27.3 ± 11.7% with EES (mean difference −2.7%, upper limit of one-sided 97.5% confidence limit 0.7%, pre-specified margin of non-inferiority 5%, P non-inferiority <0.001). The rate of the device-oriented composite of cardiac death/target vessel MI/target lesion revascularization [BRS: 12 (7.0%) vs. EES: 6 (6.7%), hazard ratio (HR) 1.04, 95% confidence interval (CI) 0.39–2.78] and definite/probable stent thrombosis [3 (1.7%) vs. 2 (2.3%), HR 0.76, 95% CI 0.13–4.56] were comparable in both groups. Conclusion: In patients undergoing PCI for acute MI BRS were non-inferior to EES for percentage diameter stenosis at angiographic follow-up. Rates of clinical events were comparable between the treatment groups, although the study was not powered to detect differences in clinical outcomes. Clinical trial registration: The trial was registered atwww.clinicaltrials.gov (NCT01942070). … (more)
- Is Part Of:
- European heart journal. Volume 40:Number 2(2019)
- Journal:
- European heart journal
- Issue:
- Volume 40:Number 2(2019)
- Issue Display:
- Volume 40, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 40
- Issue:
- 2
- Issue Sort Value:
- 2019-0040-0002-0000
- Page Start:
- 167
- Page End:
- 176
- Publication Date:
- 2018-12-05
- Subjects:
- Acute myocardial infarction -- Angiographic follow-up -- Bioresorbable scaffold -- Drug-eluting stent -- Randomized clinical trial
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/ehy710 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11816.xml