Accuracy evaluation of automated electrochemiluminescence immunoassay for everolimus and sirolimus compared to liquid chromatography‐tandem mass spectrometry. Issue 7 (14th June 2019)
- Record Type:
- Journal Article
- Title:
- Accuracy evaluation of automated electrochemiluminescence immunoassay for everolimus and sirolimus compared to liquid chromatography‐tandem mass spectrometry. Issue 7 (14th June 2019)
- Main Title:
- Accuracy evaluation of automated electrochemiluminescence immunoassay for everolimus and sirolimus compared to liquid chromatography‐tandem mass spectrometry
- Authors:
- Lee, Eun Jin
Kim, Hyun‐Ki
Ahn, Sunyoung
Lee, Woochang
Kim, Hyun Soo
Chun, Sail
Min, Won‐Ki - Abstract:
- Abstract: Background: We evaluated the analytical performance of a newly developed electrochemiluminescence immunoassay for everolimus and sirolimus compared to that of liquid chromatography‐tandem mass spectrometry (LC‐MS/MS). Methods: According to Clinical and Laboratory Standards Institute guidelines, the analytical performance including precision, recovery, linearity, and carryover was evaluated. For correlation evaluation, the results of Elecsys ® analysis of everolimus and sirolimus were compared with those of LC‐MS/MS using 120 samples from patients treated with everolimus or sirolimus. Results: The within‐run and total imprecision values were as follows: 2.3%‐4.5% and 4.5%‐6.4% for the everolimus assay; 3.3%‐4.8% and 4.7%‐8.1% for the sirolimus assay, respectively. The measured concentration was linear over the range of 0.718‐27.585 ng/mL for everolimus analysis and 0.789‐26.880 ng/mL for sirolimus analysis (all R 2 > 0.99). Recovery was 93.5%‐105.5% for the everolimus assay and 99.2%‐109.1% for the sirolimus assay (except lowest levels). Carryover was −1.09% for the everolimus assay and −0.12% for the sirolimus assay. The results of the two chemiluminescence immunoassays showed acceptable correlations with those of LC‐MS/MS ( R = 0.9585 and R = 0.9799, respectively). The two immunoassays showed slightly proportional biases compared to LC‐MS/MS. Conclusion: Elecsys ® Everolimus and Sirolimus assays showed acceptable analytical performance in precision, linearity,Abstract: Background: We evaluated the analytical performance of a newly developed electrochemiluminescence immunoassay for everolimus and sirolimus compared to that of liquid chromatography‐tandem mass spectrometry (LC‐MS/MS). Methods: According to Clinical and Laboratory Standards Institute guidelines, the analytical performance including precision, recovery, linearity, and carryover was evaluated. For correlation evaluation, the results of Elecsys ® analysis of everolimus and sirolimus were compared with those of LC‐MS/MS using 120 samples from patients treated with everolimus or sirolimus. Results: The within‐run and total imprecision values were as follows: 2.3%‐4.5% and 4.5%‐6.4% for the everolimus assay; 3.3%‐4.8% and 4.7%‐8.1% for the sirolimus assay, respectively. The measured concentration was linear over the range of 0.718‐27.585 ng/mL for everolimus analysis and 0.789‐26.880 ng/mL for sirolimus analysis (all R 2 > 0.99). Recovery was 93.5%‐105.5% for the everolimus assay and 99.2%‐109.1% for the sirolimus assay (except lowest levels). Carryover was −1.09% for the everolimus assay and −0.12% for the sirolimus assay. The results of the two chemiluminescence immunoassays showed acceptable correlations with those of LC‐MS/MS ( R = 0.9585 and R = 0.9799, respectively). The two immunoassays showed slightly proportional biases compared to LC‐MS/MS. Conclusion: Elecsys ® Everolimus and Sirolimus assays showed acceptable analytical performance in precision, linearity, and correlation compared to LC‐MS/MS These methods can be adopted in the clinical laboratory for rapid therapeutic drug monitoring of patients who require treatment with immunosuppressants. … (more)
- Is Part Of:
- Journal of clinical laboratory analysis. Volume 33:Issue 7(2019)
- Journal:
- Journal of clinical laboratory analysis
- Issue:
- Volume 33:Issue 7(2019)
- Issue Display:
- Volume 33, Issue 7 (2019)
- Year:
- 2019
- Volume:
- 33
- Issue:
- 7
- Issue Sort Value:
- 2019-0033-0007-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2019-06-14
- Subjects:
- everolimus -- immunoassay -- liquid chromatography‐tandem mass spectrometry -- sirolimus -- therapeutic drug monitoring
Diagnosis, Laboratory -- Periodicals
Medical laboratory technology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcla.22941 ↗
- Languages:
- English
- ISSNs:
- 0887-8013
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.520000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11814.xml