Effects of blood sample handling procedures on measurable interleukin 6 in plasma and serum. Issue 7 (26th May 2019)
- Record Type:
- Journal Article
- Title:
- Effects of blood sample handling procedures on measurable interleukin 6 in plasma and serum. Issue 7 (26th May 2019)
- Main Title:
- Effects of blood sample handling procedures on measurable interleukin 6 in plasma and serum
- Authors:
- Gong, Yan
Liang, Shaocong
Zeng, Lei
Ni, Yanli
Zhou, Shaosong
Yuan, Xiaopeng - Abstract:
- Abstract: Introduction: Interleukin‐6(IL‐6) measurement is used as a biomarker in medical diagnosis, therapy, and prognosis in various diseases. However, several pre‐analytical factors may yield a false IL‐6 result. In this study, we set out to investigate the effects of corrected blood sample handling procedures on measurable IL‐6. Method: EDTA plasma and serum samples were collected from 45 healthy individuals. The participants were divided into three groups to perform different handling procedures. Different centrifugal timing, storage temperature, and time were executed on the samples. The changed trends of IL‐6 levels were analyzed. Results: At baseline, while the paired plasma and serum IL‐6 values had a good correlation, the plasma levels were higher than serum. In general, the unseparated EDTA plasma kept steady with time. With the increase in storage temperature and time, a more pronounced rise in unseparated serum IL‐6 was observed. Nevertheless, the samples in Group 3 which centrifuged and separated immediately kept stable after a different temperature and longtime storage. Conclusion: Sample types, centrifugal timing, storage temperature, and time may affect the IL‐6 levels. A standard blood sample handling procedure should be performed to ensure the accuracy and stability of IL‐6 values.
- Is Part Of:
- Journal of clinical laboratory analysis. Volume 33:Issue 7(2019)
- Journal:
- Journal of clinical laboratory analysis
- Issue:
- Volume 33:Issue 7(2019)
- Issue Display:
- Volume 33, Issue 7 (2019)
- Year:
- 2019
- Volume:
- 33
- Issue:
- 7
- Issue Sort Value:
- 2019-0033-0007-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2019-05-26
- Subjects:
- centrifugal timing -- interleukin‐6 -- sample types -- storage time -- temperature
Diagnosis, Laboratory -- Periodicals
Medical laboratory technology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcla.22924 ↗
- Languages:
- English
- ISSNs:
- 0887-8013
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.520000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11814.xml