Comparison of performance characteristics between high‐performance liquid chromatography and latex agglutination turbidimetric immunoassay for therapeutic drug monitoring of zonisamide. Issue 7 (20th June 2019)
- Record Type:
- Journal Article
- Title:
- Comparison of performance characteristics between high‐performance liquid chromatography and latex agglutination turbidimetric immunoassay for therapeutic drug monitoring of zonisamide. Issue 7 (20th June 2019)
- Main Title:
- Comparison of performance characteristics between high‐performance liquid chromatography and latex agglutination turbidimetric immunoassay for therapeutic drug monitoring of zonisamide
- Authors:
- Eto, Daiki
Tanaka, Ryota
Suzuki, Yosuke
Sato, Yuhki
Itoh, Hiroki - Abstract:
- Abstract: Background: Recently, the Nanopia ® TDM Zonisamide reagent using the latex particle‐enhanced turbidimetric immunoassay (LTIA) method was developed. The aim of this study was to compare the differences in serum zonisamide (ZNS) concentrations quantified by the high‐performance liquid chromatography (HPLC) method and the LTIA method using a TBA‐25FR analyzer. Methods: A total of 78 samples from 33 patients were quantified by both HPLC and LTIA methods. Deproteinization was used as pretreatment for the HPLC method. The ZNS concentrations quantified by two methods were compared. Results: The HPLC method had intra‐ and inter‐day precision lower than 1.86% and 9.00%, and accuracy better than 2.44% and 6.33%, respectively. The LTIA method showed intra‐ and inter‐day precision lower than 2.50% and 5.20%, and accuracy better than 15.80% and 10.60%, respectively. The lower limits of quantification for the HPLC and LTIA methods were 1.0 and 5.0 µg/mL, respectively. The ZNS concentration quantified by the HPLC method correlated strongly with that by the LTIA method ( r = 0.953, P < 0.001). A Bland‐Altman plot suggested no systematic error between ZNS concentrations quantified by HPLC and LTIA methods. Conclusion: This study confirmed no differences between the concentrations quantified by the HPLC and LTIA methods at both high and low concentrations, demonstrating the confidence of measurement by the LTIA method.
- Is Part Of:
- Journal of clinical laboratory analysis. Volume 33:Issue 7(2019)
- Journal:
- Journal of clinical laboratory analysis
- Issue:
- Volume 33:Issue 7(2019)
- Issue Display:
- Volume 33, Issue 7 (2019)
- Year:
- 2019
- Volume:
- 33
- Issue:
- 7
- Issue Sort Value:
- 2019-0033-0007-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2019-06-20
- Subjects:
- antiepileptic -- high‐performance liquid chromatography -- latex‐enhanced turbidimetric immunoassay -- therapeutic drug monitoring -- zonisamide
Diagnosis, Laboratory -- Periodicals
Medical laboratory technology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcla.22940 ↗
- Languages:
- English
- ISSNs:
- 0887-8013
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.520000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11814.xml