Prosthetic replacement of the ocular surface ecosystem for corneal irregularity: Visual improvement and optical device characteristics. Issue 5 (October 2019)
- Record Type:
- Journal Article
- Title:
- Prosthetic replacement of the ocular surface ecosystem for corneal irregularity: Visual improvement and optical device characteristics. Issue 5 (October 2019)
- Main Title:
- Prosthetic replacement of the ocular surface ecosystem for corneal irregularity: Visual improvement and optical device characteristics
- Authors:
- Kumar, Preetam
Mohamed, Ashik
Bhombal, Faiza
Dumpati, Srikanth
Vaddavalli, Pravin K. - Abstract:
- Highlights: Prosthetic Replacement of Ocular Surface Ecosystem (PROSE) lenses serves as a viable option in all forms of irregular corneas in terms of visual rehabilitation. Corneal topography can potentially help in establishing an objective paradigm for PROSE lens parameter selection. Anterior chamber depth can serve as a better indicator for selection of contact lens vault compared to corneal curvature. Abstract: Purpose: To describe patterns of prescribing Prosthetic Replacement of Ocular Surface Ecosystem (PROSE) in irregular corneas and compare various components of lens design. Methods: Design: Retrospective, observational case series. 244 eyes of 173 patients with keratoconus (n=178), pellucid marginal degeneration (n=21), keratoglobus (n=6), following refractive surgery (n=19) and following keratoplasty (n=20) fitted with the PROSE device were retrospectively analyzed. Simulated keratometry value along the steep meridian (Steep-K) and anterior chamber depth (ACD) were measured using Scheimpflug imaging. Improvement in visual acuity and parameters of lens design such as vault, front surface eccentricity (FSE) and toricity were analyzed and compared across all conditions. Results: PROSE improved visual acuity, both uncorrected (median, 1.30 logMAR) and spectacle-corrected (median, 0.60 logMAR), to a median of 0.22 logMAR. Positive correlation was observed between Steep-K and ACD with lens vault, especially in keratoconus. Multiple regression analysis established ACD asHighlights: Prosthetic Replacement of Ocular Surface Ecosystem (PROSE) lenses serves as a viable option in all forms of irregular corneas in terms of visual rehabilitation. Corneal topography can potentially help in establishing an objective paradigm for PROSE lens parameter selection. Anterior chamber depth can serve as a better indicator for selection of contact lens vault compared to corneal curvature. Abstract: Purpose: To describe patterns of prescribing Prosthetic Replacement of Ocular Surface Ecosystem (PROSE) in irregular corneas and compare various components of lens design. Methods: Design: Retrospective, observational case series. 244 eyes of 173 patients with keratoconus (n=178), pellucid marginal degeneration (n=21), keratoglobus (n=6), following refractive surgery (n=19) and following keratoplasty (n=20) fitted with the PROSE device were retrospectively analyzed. Simulated keratometry value along the steep meridian (Steep-K) and anterior chamber depth (ACD) were measured using Scheimpflug imaging. Improvement in visual acuity and parameters of lens design such as vault, front surface eccentricity (FSE) and toricity were analyzed and compared across all conditions. Results: PROSE improved visual acuity, both uncorrected (median, 1.30 logMAR) and spectacle-corrected (median, 0.60 logMAR), to a median of 0.22 logMAR. Positive correlation was observed between Steep-K and ACD with lens vault, especially in keratoconus. Multiple regression analysis established ACD as the most reliable factor while choosing vault. FSE value of 0.6 was the most common across diagnostic subgroups. The distribution of FSE values did not differ between keratoconus patients with Steep keratometry of <60D or those >60D. In every diagnostic subgroup, at least 20% of eyes required a lens design of with-the-rule toricity of haptic. Conclusion: The PROSE device resulted in significant improvement in vision in this population. A trend of prescribing higher lens vault with increased keratometry value was evident especially in keratoconus. ACD appeared to be more important than Steep K in vault selection. An FSE of 0.6 and vertical peripheral lens toricity were used most frequently in this subset of patients. … (more)
- Is Part Of:
- Contact lens & anterior eye. Volume 42:Issue 5(2019)
- Journal:
- Contact lens & anterior eye
- Issue:
- Volume 42:Issue 5(2019)
- Issue Display:
- Volume 42, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 42
- Issue:
- 5
- Issue Sort Value:
- 2019-0042-0005-0000
- Page Start:
- 526
- Page End:
- 532
- Publication Date:
- 2019-10
- Subjects:
- Contact lens -- Keratoconus -- Topography -- Apical clearance -- Three-point touchn
Anterior segment (Eye) -- Periodicals
Contact lenses -- Periodicals
Segment antérieur (Œil) -- Périodiques
Lentilles de contact -- Périodiques
617.752305 - Journal URLs:
- http://firstsearch.oclc.org/journal=1367-0484;screen=info;ECOIP ↗
http://www.sciencedirect.com/science/journal/13670484 ↗
http://www.contactlensjournal.com/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13670484 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13670484 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clae.2019.05.001 ↗
- Languages:
- English
- ISSNs:
- 1367-0484
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3424.971000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11807.xml