Dosimetric and preparation procedures for irradiating biological models with pulsed electron beam at ultra-high dose-rate. (October 2019)
- Record Type:
- Journal Article
- Title:
- Dosimetric and preparation procedures for irradiating biological models with pulsed electron beam at ultra-high dose-rate. (October 2019)
- Main Title:
- Dosimetric and preparation procedures for irradiating biological models with pulsed electron beam at ultra-high dose-rate
- Authors:
- Jorge, Patrik Gonçalves
Jaccard, Maud
Petersson, Kristoffer
Gondré, Maude
Durán, Maria Teresa
Desorgher, Laurent
Germond, Jean-François
Liger, Philippe
Vozenin, Marie-Catherine
Bourhis, Jean
Bochud, François
Moeckli, Raphaël
Bailat, Claude - Abstract:
- Highlights: At conventional dose-rates (few Gy/min), the alanine, the Gafchromic films, the TLD and the ionization chamber agree within 2%. For dose-rates up to 1050 Gy/s, the alanine, the Gafchromic films and the TLD agree within 3%, showing no dose-rate dependency. Thanks to the dosimetric procedure, the uncertainty in the delivered dose for the biological experiments is estimated to be about 3%. Without this dosimetric procedure, deviations between the delivered dose and the prescription dose can reach 15%. Abstract: Purpose: Preclinical studies using a new treatment modality called FLASH Radiotherapy (FLASH-RT) need a two-phase procedure to ensure minimal uncertainties in the delivered dose. The first phase requires a new investigation of the reference dosimetry lying outside the conventional metrology framework from national metrology institutes but necessary to obtain traceability, repeatability, and stability of irradiations. The second consists of performing special quality assurance procedure prior to irradiation. Materials and Methods: The Oriatron eRT6 (PMB-Alcen, France) is an experimental high dose-per-pulse linear accelerator, delivering a 6 MeV pulsed electron beam with mean dose-rates, ranging from a few Gy/min up to thousands of Gy/s. Absolute dosimetry is investigated with alanine, thermo-luminescent dosimeters (TLD) and radiochromic films as well as an ionization chamber for relative stability. The beam characteristic and dosimetry are prepared for threeHighlights: At conventional dose-rates (few Gy/min), the alanine, the Gafchromic films, the TLD and the ionization chamber agree within 2%. For dose-rates up to 1050 Gy/s, the alanine, the Gafchromic films and the TLD agree within 3%, showing no dose-rate dependency. Thanks to the dosimetric procedure, the uncertainty in the delivered dose for the biological experiments is estimated to be about 3%. Without this dosimetric procedure, deviations between the delivered dose and the prescription dose can reach 15%. Abstract: Purpose: Preclinical studies using a new treatment modality called FLASH Radiotherapy (FLASH-RT) need a two-phase procedure to ensure minimal uncertainties in the delivered dose. The first phase requires a new investigation of the reference dosimetry lying outside the conventional metrology framework from national metrology institutes but necessary to obtain traceability, repeatability, and stability of irradiations. The second consists of performing special quality assurance procedure prior to irradiation. Materials and Methods: The Oriatron eRT6 (PMB-Alcen, France) is an experimental high dose-per-pulse linear accelerator, delivering a 6 MeV pulsed electron beam with mean dose-rates, ranging from a few Gy/min up to thousands of Gy/s. Absolute dosimetry is investigated with alanine, thermo-luminescent dosimeters (TLD) and radiochromic films as well as an ionization chamber for relative stability. The beam characteristic and dosimetry are prepared for three different setups. Results: A cross-check between alanine, films and TLD revealed a dose agreement within 3% for dose-rates between 0.078 Gy/s and 1050 Gy/s, showing that these dosimeters are suitable for absolute dosimetry for FLASH-RT. In absence of appropriate setup dependent corrections, active dosimetry can reveal dose deviations up to 15% of the prescribed dose. These differences reduce to less than 3% when our dosimetric procedure is applied. Conclusion: We developed procedures to accurately irradiate biological models. Our method is based on validated absolute dosimeters and extends their use to routine FLASH irradiations. We reached an agreement of 3% between the delivered and prescribed dose and developed the requirements needed for workflows of preclinical and clinical studies. … (more)
- Is Part Of:
- Radiotherapy and oncology. Volume 139(2019)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 139(2019)
- Issue Display:
- Volume 139, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 139
- Issue:
- 2019
- Issue Sort Value:
- 2019-0139-2019-0000
- Page Start:
- 34
- Page End:
- 39
- Publication Date:
- 2019-10
- Subjects:
- Dosimetry -- FLASH -- Radiotherapy -- Ultra-high dose-rate -- Passive dosimetry
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2019.05.004 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11811.xml