Precision in 3-Dimensional Surface Imaging of the Face: A Handheld Scanner Comparison Performed in a Cadaveric Model. (15th October 2018)
- Record Type:
- Journal Article
- Title:
- Precision in 3-Dimensional Surface Imaging of the Face: A Handheld Scanner Comparison Performed in a Cadaveric Model. (15th October 2018)
- Main Title:
- Precision in 3-Dimensional Surface Imaging of the Face: A Handheld Scanner Comparison Performed in a Cadaveric Model
- Authors:
- Koban, Konstantin C
Cotofana, Sebastian
Frank, Konstantin
Green, Jeremy B
Etzel, Lucas
Li, Zhouxiao
Giunta, Riccardo E
Schenck, Thilo L - Abstract:
- Abstract: Background: Handheld 3-dimensional surface imaging (3DSI) devices of various precision are becoming more versatile in their applications and more widely accepted by clinicians for documentation. Objectives: The authors sought to compare the precision of facial volumetric change measurements of 3 3DSI devices in the cadaveric model: Eva (Artec 3D Inc., Luxembourg), Sense (3D Systems, Rock Hill, SC), and iSense (3D Systems, Rock Hill, SC). Methods: A total of 336 scanning and analysis procedures were carried out in 4 cephalic specimens (mean age, 77.25 ± 24.3 years; mean BMI, 21.76 ± 6.6 kg/m 2 ). Two superficial and 2 supraperiosteal regions of interest were injected with 0.5-cc aliquots and subsequently scanned using the 3 different scanners. Correlation coefficients between the injected and measured volume were computed. Results: The correlation coefficient for the Eva scanner was for subcutaneous regions of interest rp = 0.935 and for the supraperiosteal regions of interest rp = 0.966, compared with rp = 0.760 and rp = 0.364 (superficial vs supraperiosteal) for the Sense and rp = 0.694 and rp = 0.382 (superficial vs supraperiosteal) for the iSense scanner. Conclusions: 3DSI devices are capable of measuring surface volume changes of the face at a level of 0.5-cc surface volume change and can thus be regarded as useful tools in the preinterventional, intrainterventional, and postinterventional phases of a treatment. One of the 3 evaluated scanners provided veryAbstract: Background: Handheld 3-dimensional surface imaging (3DSI) devices of various precision are becoming more versatile in their applications and more widely accepted by clinicians for documentation. Objectives: The authors sought to compare the precision of facial volumetric change measurements of 3 3DSI devices in the cadaveric model: Eva (Artec 3D Inc., Luxembourg), Sense (3D Systems, Rock Hill, SC), and iSense (3D Systems, Rock Hill, SC). Methods: A total of 336 scanning and analysis procedures were carried out in 4 cephalic specimens (mean age, 77.25 ± 24.3 years; mean BMI, 21.76 ± 6.6 kg/m 2 ). Two superficial and 2 supraperiosteal regions of interest were injected with 0.5-cc aliquots and subsequently scanned using the 3 different scanners. Correlation coefficients between the injected and measured volume were computed. Results: The correlation coefficient for the Eva scanner was for subcutaneous regions of interest rp = 0.935 and for the supraperiosteal regions of interest rp = 0.966, compared with rp = 0.760 and rp = 0.364 (superficial vs supraperiosteal) for the Sense and rp = 0.694 and rp = 0.382 (superficial vs supraperiosteal) for the iSense scanner. Conclusions: 3DSI devices are capable of measuring surface volume changes of the face at a level of 0.5-cc surface volume change and can thus be regarded as useful tools in the preinterventional, intrainterventional, and postinterventional phases of a treatment. One of the 3 evaluated scanners provided very high correlation coefficients between the injected and the measured volume (Eva), whereas the other evaluated 3DSI devices provided moderate (Sense) and low (iSense) coefficients. … (more)
- Is Part Of:
- Aesthetic surgery journal. Volume 39:Number 4(2019)
- Journal:
- Aesthetic surgery journal
- Issue:
- Volume 39:Number 4(2019)
- Issue Display:
- Volume 39, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 39
- Issue:
- 4
- Issue Sort Value:
- 2019-0039-0004-0000
- Page Start:
- NP36
- Page End:
- NP44
- Publication Date:
- 2018-10-15
- Subjects:
- Surgery, Plastic -- Periodicals
617.95 - Journal URLs:
- http://asj.oxfordjournals.org/content/ ↗
http://aes.sagepub.com/content/by/year ↗
http://www.mosby.com/aesthetic ↗
http://online.sagepub.com/ ↗
http://www.sciencedirect.com/science/journal/1090820X ↗ - DOI:
- 10.1093/asj/sjy242 ↗
- Languages:
- English
- ISSNs:
- 1090-820X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0730.384000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11810.xml