Surgical smoke: still an underestimated health hazard in the operating theatre. (2nd November 2018)
- Record Type:
- Journal Article
- Title:
- Surgical smoke: still an underestimated health hazard in the operating theatre. (2nd November 2018)
- Main Title:
- Surgical smoke: still an underestimated health hazard in the operating theatre
- Authors:
- Kocher, Gregor J
Sesia, Sergio B
Lopez-Hilfiker, Felipe
Schmid, Ralph A - Abstract:
- Abstract: OBJECTIVES: Smoke generated from electrocautery dissection contains irritating and/or carcinogenic components. The aim of this study was to investigate the effectiveness of a mobile smoke evacuation system (SES) in protecting surgical personnel from these hazardous fumes. METHODS: Standardized cuts with an electrocautery device were performed on fresh porcine tissue, and the generated surgical fume was analysed with and without the additional use of a mobile SES using a real-time proton-transfer-reaction time-of-flight mass spectrometer. Furthermore, 2 different surgical masks were tested to investigate their filter capacity. RESULTS: Several toxic and/or carcinogenic volatile organic compounds including 1, 3-butadiene, benzene and furfural were found in concentrations clearly above the limits that were set by the National Institute of Occupational Safety and Health: 1, 3-butadiene at 19.06 ± 1.54 ppm (limit: 5 ppm), benzene at 6.21 ± 1.33 ppm (limit: 0.5 ppm) and furfural at 14.34 ± 2.97 ppm (limit: 2 ppm). Although the mobile SES was able to reduce these substances to a certain degree, butadiene and benzene still remained above the permissible exposure limits with concentrations of 14.21 ± 0.07 and 1.16 ± 0.05, respectively. Both surgical masks were unable to reduce the 'inhaled' concentrations of volatile organic compounds. CONCLUSIONS: Although the SES reduced the concentrations of most of the detected volatile organic compounds to a certain amount, especiallyAbstract: OBJECTIVES: Smoke generated from electrocautery dissection contains irritating and/or carcinogenic components. The aim of this study was to investigate the effectiveness of a mobile smoke evacuation system (SES) in protecting surgical personnel from these hazardous fumes. METHODS: Standardized cuts with an electrocautery device were performed on fresh porcine tissue, and the generated surgical fume was analysed with and without the additional use of a mobile SES using a real-time proton-transfer-reaction time-of-flight mass spectrometer. Furthermore, 2 different surgical masks were tested to investigate their filter capacity. RESULTS: Several toxic and/or carcinogenic volatile organic compounds including 1, 3-butadiene, benzene and furfural were found in concentrations clearly above the limits that were set by the National Institute of Occupational Safety and Health: 1, 3-butadiene at 19.06 ± 1.54 ppm (limit: 5 ppm), benzene at 6.21 ± 1.33 ppm (limit: 0.5 ppm) and furfural at 14.34 ± 2.97 ppm (limit: 2 ppm). Although the mobile SES was able to reduce these substances to a certain degree, butadiene and benzene still remained above the permissible exposure limits with concentrations of 14.21 ± 0.07 and 1.16 ± 0.05, respectively. Both surgical masks were unable to reduce the 'inhaled' concentrations of volatile organic compounds. CONCLUSIONS: Although the SES reduced the concentrations of most of the detected volatile organic compounds to a certain amount, especially the carcinogenic substances, butadiene and benzene remained high above exposure limits. According to the abovementioned significant data, further investigation on this topic is imperative, especially when considering that surgical masks were absolutely ineffective in protecting individuals from the toxic smoke and that the cautery was only used for 10 s in this experiment. … (more)
- Is Part Of:
- European journal of cardio-thoracic surgery. Volume 55:Number 4(2019)
- Journal:
- European journal of cardio-thoracic surgery
- Issue:
- Volume 55:Number 4(2019)
- Issue Display:
- Volume 55, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 55
- Issue:
- 4
- Issue Sort Value:
- 2019-0055-0004-0000
- Page Start:
- 626
- Page End:
- 631
- Publication Date:
- 2018-11-02
- Subjects:
- Smoke -- Plume -- Electrocautery -- Benzene -- Furfural -- Mass spectrometer
Heart -- Surgery -- Periodicals
Chest -- Surgery -- Periodicals
617.54 - Journal URLs:
- http://ejcts.oxfordjournals.org/ ↗
http://www.sciencedirect.com/science/journal/10107940 ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ejcts/ezy356 ↗
- Languages:
- English
- ISSNs:
- 1010-7940
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.725620
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11792.xml