Comparison of mitral valve geometrical effect of percutaneous edge-to-edge repair between central and eccentric functional mitral regurgitation: clinical implications. (9th August 2018)
- Record Type:
- Journal Article
- Title:
- Comparison of mitral valve geometrical effect of percutaneous edge-to-edge repair between central and eccentric functional mitral regurgitation: clinical implications. (9th August 2018)
- Main Title:
- Comparison of mitral valve geometrical effect of percutaneous edge-to-edge repair between central and eccentric functional mitral regurgitation: clinical implications
- Authors:
- Utsunomiya, Hiroto
Itabashi, Yuji
Kobayashi, Sayuki
Yoshida, Jun
Ikenaga, Hiroki
Rader, Florian
Hussaini, Asma
Makar, Moody
Trento, Alfredo
Siegel, Robert J
Kar, Saibal
Shiota, Takahiro - Abstract:
- Abstract: Aims: Percutaneous edge-to-edge repair alters mitral valve (MV) geometry in functional mitral regurgitation (FMR). We sought to characterize MV morphology in patients with central and eccentric FMR, compare the geometrical effect of MitraClip therapy, and elucidate different mechanisms of MR improvement according to FMR subtypes. Methods and results: Seventy-six symptomatic patients with Grade 3 to 4+ FMR (central, n = 39; eccentric, n = 37) underwent three-dimensional transoesophageal echocardiography during MitraClip implantation. We defined procedural success as a reduction of MR by ≥1 grade with having a residual mitral regurgitation (MR) of ≤ grade 2+. Procedural success rate was similar between central and eccentric FMR (77% vs. 78%, P = 0.55). After MitraClip, the reduction in anterior-posterior diameter did not differ between FMR subtypes, but patients with eccentric FMR had a greater reduction in the averaged tethering angle difference ( P < 0.001) with less reduction in tenting volume and height (both P < 0.001) than did patients with central FMR. On multivariable analysis, in central FMR, MR reduction post-clip was associated with shortening in anterior-posterior diameter [coefficient 0.388, 95% confidence interval (CI) 0.216–0.561; P < 0.001] and an increase in coaptation area (coefficient 0.117, 95% CI 0.039–0.194; P = 0.004), whereas in eccentric FMR MR reduction was mainly associated with a decrease in the averaged tethering angleAbstract: Aims: Percutaneous edge-to-edge repair alters mitral valve (MV) geometry in functional mitral regurgitation (FMR). We sought to characterize MV morphology in patients with central and eccentric FMR, compare the geometrical effect of MitraClip therapy, and elucidate different mechanisms of MR improvement according to FMR subtypes. Methods and results: Seventy-six symptomatic patients with Grade 3 to 4+ FMR (central, n = 39; eccentric, n = 37) underwent three-dimensional transoesophageal echocardiography during MitraClip implantation. We defined procedural success as a reduction of MR by ≥1 grade with having a residual mitral regurgitation (MR) of ≤ grade 2+. Procedural success rate was similar between central and eccentric FMR (77% vs. 78%, P = 0.55). After MitraClip, the reduction in anterior-posterior diameter did not differ between FMR subtypes, but patients with eccentric FMR had a greater reduction in the averaged tethering angle difference ( P < 0.001) with less reduction in tenting volume and height (both P < 0.001) than did patients with central FMR. On multivariable analysis, in central FMR, MR reduction post-clip was associated with shortening in anterior-posterior diameter [coefficient 0.388, 95% confidence interval (CI) 0.216–0.561; P < 0.001] and an increase in coaptation area (coefficient 0.117, 95% CI 0.039–0.194; P = 0.004), whereas in eccentric FMR MR reduction was mainly associated with a decrease in the averaged tethering angle difference (coefficient 0.050, 95% CI 0.021–0.078; P = 0.001). Conclusion: MV geometrical effect and its association with MR improvement after MitraClip therapy differ according to FMR subtypes. Our results indicate the MR jet direction and the leaflet tethering pattern may be considered in the strategy for percutaneous treatment for FMR. … (more)
- Is Part Of:
- European heart journal. Volume 20:Number 4(2019)
- Journal:
- European heart journal
- Issue:
- Volume 20:Number 4(2019)
- Issue Display:
- Volume 20, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 20
- Issue:
- 4
- Issue Sort Value:
- 2019-0020-0004-0000
- Page Start:
- 455
- Page End:
- 466
- Publication Date:
- 2018-08-09
- Subjects:
- functional mitral regurgitation -- percutaneous mitral valve repair -- 3D transoesophageal echocardiography
Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.10754 - Journal URLs:
- http://ehjcimaging.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/jey117 ↗
- Languages:
- English
- ISSNs:
- 2047-2404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11801.xml