Pacing parameters and success rates of permanent His-bundle pacing in patients with narrow QRS: a single-centre experience. Issue 5 (15th December 2018)
- Record Type:
- Journal Article
- Title:
- Pacing parameters and success rates of permanent His-bundle pacing in patients with narrow QRS: a single-centre experience. Issue 5 (15th December 2018)
- Main Title:
- Pacing parameters and success rates of permanent His-bundle pacing in patients with narrow QRS: a single-centre experience
- Authors:
- Su, Lan
Wu, Shengjie
Wang, Songjie
Wang, Zhengxian
Xiao, Fangyi
Shan, Peiren
Zhou, Hao
Huang, Zhouqing
Xu, Lei
Huang, Weijian - Abstract:
- Abstract: Aims: High and unstable capture thresholds affect the success rate of permanent His-bundle pacing (HBP). We aimed to introduce the modified techniques during different periods and the corresponding success rate of HBP implantation. Methods and results: Patients from a single centre who had intrinsic QRS < 120 ms and HBP attempts were included in the study. The success rate and pacing parameters were described for three periods based on procedural modifications, i.e. Stage 1 using the conventional HBP procedure (August 2012 to May 2013), Stage 2 with addition of the dual-lead method (June 2013 to October 2014), and Stage 3 with the further addition of stability assessment during fixation (November 2014 to October 2016). The patients with successful permanent HBP were followed. A total of 310 patients were included with the average age of 70.3 ± 10.7 years. The success rate of acute HBP was 84.85%, 98.3%, and 99.20% during Stages 1–3, respectively ( P < 0.001). The permanent HBP implantation rates increased from 77.3% during Stage 1 to 85.7% during Stage 2 and 89.6% during Stage 3 ( P = 0.07). The acute His-bundle capture threshold reduced from 1.30 ± 0.7 V/0.5 ms during Stage 1 to 1.11 ± 0.6 V/0.5 ms during Stage 2 and further to 0.85 ± 0.51 V/0.5 ms during Stage 3 ( P < 0.001). At the 12-month follow-up, the mean change in the HBP threshold decreased from 0.60 ± 0.59 V/0.5 ms during Stage 1 to 0.33 ± 0.39 V/0.5 ms during Stage 3 ( P = 0.002). Conclusion: TheAbstract: Aims: High and unstable capture thresholds affect the success rate of permanent His-bundle pacing (HBP). We aimed to introduce the modified techniques during different periods and the corresponding success rate of HBP implantation. Methods and results: Patients from a single centre who had intrinsic QRS < 120 ms and HBP attempts were included in the study. The success rate and pacing parameters were described for three periods based on procedural modifications, i.e. Stage 1 using the conventional HBP procedure (August 2012 to May 2013), Stage 2 with addition of the dual-lead method (June 2013 to October 2014), and Stage 3 with the further addition of stability assessment during fixation (November 2014 to October 2016). The patients with successful permanent HBP were followed. A total of 310 patients were included with the average age of 70.3 ± 10.7 years. The success rate of acute HBP was 84.85%, 98.3%, and 99.20% during Stages 1–3, respectively ( P < 0.001). The permanent HBP implantation rates increased from 77.3% during Stage 1 to 85.7% during Stage 2 and 89.6% during Stage 3 ( P = 0.07). The acute His-bundle capture threshold reduced from 1.30 ± 0.7 V/0.5 ms during Stage 1 to 1.11 ± 0.6 V/0.5 ms during Stage 2 and further to 0.85 ± 0.51 V/0.5 ms during Stage 3 ( P < 0.001). At the 12-month follow-up, the mean change in the HBP threshold decreased from 0.60 ± 0.59 V/0.5 ms during Stage 1 to 0.33 ± 0.39 V/0.5 ms during Stage 3 ( P = 0.002). Conclusion: The HBP implantation success rate, pacing threshold, and its stability during follow-up were improved by using the dual-lead method and stability assessment techniques. … (more)
- Is Part Of:
- Europace. Volume 21:Issue 5(2019)
- Journal:
- Europace
- Issue:
- Volume 21:Issue 5(2019)
- Issue Display:
- Volume 21, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 21
- Issue:
- 5
- Issue Sort Value:
- 2019-0021-0005-0000
- Page Start:
- 763
- Page End:
- 770
- Publication Date:
- 2018-12-15
- Subjects:
- His-bundle pacing -- Success rate -- Threshold -- Pacing lead -- Pacemaker -- Pacemaker implantation
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euy281 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11791.xml