Lead extraction for reduction of chronic pain related to cardiovascular implantable electronic device. Issue 5 (28th January 2019)
- Record Type:
- Journal Article
- Title:
- Lead extraction for reduction of chronic pain related to cardiovascular implantable electronic device. Issue 5 (28th January 2019)
- Main Title:
- Lead extraction for reduction of chronic pain related to cardiovascular implantable electronic device
- Authors:
- Lewis, Kathryn
Dai, Mingyan
Patton, Kristen K
Cha, Yong-Mei
Pollema, Travis
Feld, Gregory K
Birgersdotter-Green, Ulrika
Pretorius, Victor - Abstract:
- Abstract: Aims: Chronic pain at the cardiovascular implantable electronic device (CIED) generator or lead insertion site that is not otherwise manageable carries a IIA indication for extraction. However, limited data exist evaluating causes of pain and outcomes of extraction in eliminating pain. A multi-centre retrospective observational study was conducted to evaluate outcomes of patients undergoing device extraction for treatment of chronic device pain. Methods and results: Twenty-seven out of 2188 lead extraction candidates (1.3%) met the chronic pain IIA indication for extraction [50 ± 16 years; 14 (51%) women]. Onset, severity, triggers, and pain management were measured before and after extraction. Device type, procedure done (with/without reimplantation), and positive tissue cultures were noted. Pain was reported as constant ( n = 14; 50%), intermittent ( n = 13; 46%), and movement-triggered ( n = 14; 50%). Average severity of pain was seven out of 10 (10 being the worst). Post-extraction, 18 (66%) received freedom from pain, including all patients with poorly formed pockets ( n = 2) and subclinical infections ( n = 2). Of the 18, 11 underwent reimplantation (61%) without recurrent pain. Nine still had pain (44 ± 17 years; seven women) after extraction. Eight of the nine underwent reimplantation, three on the contralateral chest wall and five ipsilaterally. Pain severity decreased ( n = 5), increased ( n = 1), or was unchanged ( n = 3). Conclusion: ChronicAbstract: Aims: Chronic pain at the cardiovascular implantable electronic device (CIED) generator or lead insertion site that is not otherwise manageable carries a IIA indication for extraction. However, limited data exist evaluating causes of pain and outcomes of extraction in eliminating pain. A multi-centre retrospective observational study was conducted to evaluate outcomes of patients undergoing device extraction for treatment of chronic device pain. Methods and results: Twenty-seven out of 2188 lead extraction candidates (1.3%) met the chronic pain IIA indication for extraction [50 ± 16 years; 14 (51%) women]. Onset, severity, triggers, and pain management were measured before and after extraction. Device type, procedure done (with/without reimplantation), and positive tissue cultures were noted. Pain was reported as constant ( n = 14; 50%), intermittent ( n = 13; 46%), and movement-triggered ( n = 14; 50%). Average severity of pain was seven out of 10 (10 being the worst). Post-extraction, 18 (66%) received freedom from pain, including all patients with poorly formed pockets ( n = 2) and subclinical infections ( n = 2). Of the 18, 11 underwent reimplantation (61%) without recurrent pain. Nine still had pain (44 ± 17 years; seven women) after extraction. Eight of the nine underwent reimplantation, three on the contralateral chest wall and five ipsilaterally. Pain severity decreased ( n = 5), increased ( n = 1), or was unchanged ( n = 3). Conclusion: Chronic pain at the CIED generator site can present as chronic or movement-triggered pain, and can be due to subclinical infection or a poorly formed device pocket. Extraction relieved constant and intermittent pain in two-thirds of patients. Extraction appears less successful in eliminating pain in women who undergo subsequent reimplantation. … (more)
- Is Part Of:
- Europace. Volume 21:Issue 5(2019)
- Journal:
- Europace
- Issue:
- Volume 21:Issue 5(2019)
- Issue Display:
- Volume 21, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 21
- Issue:
- 5
- Issue Sort Value:
- 2019-0021-0005-0000
- Page Start:
- 781
- Page End:
- 786
- Publication Date:
- 2019-01-28
- Subjects:
- Cardiovascular implantable electronic device -- Cardiovascular implantable electronic device lead extraction -- Pacemaker -- Implantable cardioverter-defibrillator -- Chronic pain
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euy320 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11791.xml