Brachial flow-mediated dilation by continuous monitoring of arterial cross-section with ultrasound imaging. (November 2019)
- Record Type:
- Journal Article
- Title:
- Brachial flow-mediated dilation by continuous monitoring of arterial cross-section with ultrasound imaging. (November 2019)
- Main Title:
- Brachial flow-mediated dilation by continuous monitoring of arterial cross-section with ultrasound imaging
- Authors:
- Chen, Zhen
Sultan, Laith R
Schultz, Susan M
Cary, Theodore W
Sehgal, Chandra M - Abstract:
- Objective: Impairment of flow-mediated dilation of the brachial artery is a marker of endothelial dysfunction and often predisposes atherosclerosis and cardiovascular events. In this study, we propose a user-guided automated approach for monitoring arterial cross-section during hyperemic response to improve reproducibility and sensitivity of flow-mediated dilation. Material and methods: Ultrasound imaging of the brachial artery was performed in 11 volunteers in cross-sectional and in 5 volunteers in longitudinal view. During each examination, images were recorded continuously before and after inducing ischemia. Time-dilation curves of the brachial lumen cross-section were measured by user-guided automated segmentation of brachial images with the feed-forward active contour (FFAC) algorithm. %FMD was determined by the ratio of peak dilation to the baseline value. Each measurement was repeated twice in two sessions 1 h apart on the same arm to evaluate the reproducibility of the measurements. The intra-subject variation in flow-mediated dilation between two sessions (subject-specific) and inter-group variation in flow-mediated dilation with all the subjects within a session grouped together (group-specific) were measured for FFAC. The FFAC measurements were compared with the conventional diameter measurements made using echo tracking in longitudinal views. Results: Flow-mediated dilation values for cross-sectional area were greater than those measured by diameter dilation:Objective: Impairment of flow-mediated dilation of the brachial artery is a marker of endothelial dysfunction and often predisposes atherosclerosis and cardiovascular events. In this study, we propose a user-guided automated approach for monitoring arterial cross-section during hyperemic response to improve reproducibility and sensitivity of flow-mediated dilation. Material and methods: Ultrasound imaging of the brachial artery was performed in 11 volunteers in cross-sectional and in 5 volunteers in longitudinal view. During each examination, images were recorded continuously before and after inducing ischemia. Time-dilation curves of the brachial lumen cross-section were measured by user-guided automated segmentation of brachial images with the feed-forward active contour (FFAC) algorithm. %FMD was determined by the ratio of peak dilation to the baseline value. Each measurement was repeated twice in two sessions 1 h apart on the same arm to evaluate the reproducibility of the measurements. The intra-subject variation in flow-mediated dilation between two sessions (subject-specific) and inter-group variation in flow-mediated dilation with all the subjects within a session grouped together (group-specific) were measured for FFAC. The FFAC measurements were compared with the conventional diameter measurements made using echo tracking in longitudinal views. Results: Flow-mediated dilation values for cross-sectional area were greater than those measured by diameter dilation: 33.1% for cross-sectional area compared to 22.5% for diameter. Group-specific flow-mediated dilation measurements for cross-sectional area were highly reproducible: 33.2% vs. 33.0% ( p > 0.05) with coefficient of variation CV of 0.4%. The group-specific flow-mediated dilations measured by echo tracking for the two sessions were 21.1 vs. 23.9% with CV of 9%. Subject-specific CV for cross-sectional area by FFAC was 10% ± 2% versus 24% ± 10% for the conventional approach. Using correlation as a metric of evaluation also showed better performance for cross-sectional imaging: correlation coefficient, R, between two sessions for cross-sectional area was 0.92 versus 0.72 for the conventional approach based on diameter measurements. Conclusion: Peak dilation area measured by continuous automated monitoring of cross-sectional area of the brachial artery provides more reproducible and higher-sensitivity measurement of flow-mediated dilation compared to the conventional approach of using vascular diameter measured using longitudinal imaging. … (more)
- Is Part Of:
- Ultrasound. Volume 27:Number 4(2019:Nov.)
- Journal:
- Ultrasound
- Issue:
- Volume 27:Number 4(2019:Nov.)
- Issue Display:
- Volume 27, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 27
- Issue:
- 4
- Issue Sort Value:
- 2019-0027-0004-0000
- Page Start:
- 241
- Page End:
- 251
- Publication Date:
- 2019-11
- Subjects:
- Brachial flow-mediated dilation -- active contour -- vascular image segmentation -- vascular ultrasound
Ultrasonic imaging -- Periodicals
Ultrasonography -- Periodicals
616.0754305 - Journal URLs:
- http://ult.sagepub.com/ ↗
http://www.maney.co.uk/search?fwaction=show&fwid=440 ↗
http://www.maney.co.uk/search?fwaction=show&fwid=440&fwprint=yes ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1742271X19857770 ↗
- Languages:
- English
- ISSNs:
- 1742-271X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11762.xml