Accuracy of two plasma antibody tests and faecal antigen test for non-invasive detection of H. pylori in middle-aged Caucasian general population sample. (3rd July 2018)
- Record Type:
- Journal Article
- Title:
- Accuracy of two plasma antibody tests and faecal antigen test for non-invasive detection of H. pylori in middle-aged Caucasian general population sample. (3rd July 2018)
- Main Title:
- Accuracy of two plasma antibody tests and faecal antigen test for non-invasive detection of H. pylori in middle-aged Caucasian general population sample
- Authors:
- Skrebinska, Sabine
Daugule, Ilva
Santare, Daiga
Isajevs, Sergejs
Liepniece-Karele, Inta
Rudzite, Dace
Kikuste, Ilze
Vanags, Aigars
Tolmanis, Ivars
Atstupens, Juris
Park, Jin Young
Herrero, Rolando
Leja, Marcis - Abstract:
- Abstract: Objective: The aim of the study was to assess the accuracy of two plasma Helicobacter pylori (H. pylori) antibody test-systems and a stool antigen test (SAT) system in a general population sample in Latvia. Materials and methods: Blood and faecal samples were analysed in healthy individuals (40–64 years), referred for upper gastrointestinal endoscopy according to pilot study protocol within a population-based study investigating gastric cancer prevention strategies (GISTAR pilot study). Antibodies to H. pylori were assessed in plasma by latex-agglutination test and enzyme-linked immunosorbent assay (ELISA). H. pylori antigen in faecal samples was detected by a monoclonal enzyme immunoassay-based SAT. Histological assessment of H. pylori based on a modified Giemsa staining method was used as the gold standard. Individuals having received H. pylori eradication within one year prior to enrolment were excluded. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and overall accuracy were calculated. Receiver-operating characteristic curves were designed to estimate the optimal diagnostic cut-off value of tests. Results: The analysis included 779 participants for latex-agglutination test, 1002 for ELISA and 672 individual samples for SAT. The sensitivity, specificity, PPV, NPV and overall accuracy were as follows: latex-agglutination test (86;81;87;80;84%), ELISA (97;72;83;94;86%) and SAT (87;81;87;81;85%), respectively. TheAbstract: Objective: The aim of the study was to assess the accuracy of two plasma Helicobacter pylori (H. pylori) antibody test-systems and a stool antigen test (SAT) system in a general population sample in Latvia. Materials and methods: Blood and faecal samples were analysed in healthy individuals (40–64 years), referred for upper gastrointestinal endoscopy according to pilot study protocol within a population-based study investigating gastric cancer prevention strategies (GISTAR pilot study). Antibodies to H. pylori were assessed in plasma by latex-agglutination test and enzyme-linked immunosorbent assay (ELISA). H. pylori antigen in faecal samples was detected by a monoclonal enzyme immunoassay-based SAT. Histological assessment of H. pylori based on a modified Giemsa staining method was used as the gold standard. Individuals having received H. pylori eradication within one year prior to enrolment were excluded. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and overall accuracy were calculated. Receiver-operating characteristic curves were designed to estimate the optimal diagnostic cut-off value of tests. Results: The analysis included 779 participants for latex-agglutination test, 1002 for ELISA and 672 individual samples for SAT. The sensitivity, specificity, PPV, NPV and overall accuracy were as follows: latex-agglutination test (86;81;87;80;84%), ELISA (97;72;83;94;86%) and SAT (87;81;87;81;85%), respectively. The optimal diagnostic cut-off value for ELISA test was ≥50.26 g/L. Conclusions: Although the performance of the three tests was comparable to each other, the three test systems showed suboptimal accuracy, with important implications for public health programs based on 'test-and-treat' strategy. … (more)
- Is Part Of:
- Scandinavian journal of gastroenterology. Volume 53:Number 7(2018)
- Journal:
- Scandinavian journal of gastroenterology
- Issue:
- Volume 53:Number 7(2018)
- Issue Display:
- Volume 53, Issue 7 (2018)
- Year:
- 2018
- Volume:
- 53
- Issue:
- 7
- Issue Sort Value:
- 2018-0053-0007-0000
- Page Start:
- 777
- Page End:
- 783
- Publication Date:
- 2018-07-03
- Subjects:
- H. pylori -- plasma antibody tests -- latex-agglutination -- ELISA -- stool antigen test
Gastroenterology -- Periodicals
Digestive organs -- Diseases -- Periodicals
616.33 - Journal URLs:
- http://informahealthcare.com/loi/gas ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/00365521.2018.1476909 ↗
- Languages:
- English
- ISSNs:
- 0036-5521
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8087.507000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11770.xml