A precise, sensitive and stable LC-MSMS method for detection of picomolar levels of serum aldosterone. (4th July 2018)
- Record Type:
- Journal Article
- Title:
- A precise, sensitive and stable LC-MSMS method for detection of picomolar levels of serum aldosterone. (4th July 2018)
- Main Title:
- A precise, sensitive and stable LC-MSMS method for detection of picomolar levels of serum aldosterone
- Authors:
- Lie, Margrete
Thorstensen, Ketil - Abstract:
- Abstract: Background: Accurate quantification of aldosterone is essential in the diagnosis of primary aldosteronism. Liquid chromatography-tandem mass spectrometry (LC-MSMS) analysis is increasingly being used to improve analytical sensitivity and specificity, since this technology reduces most of the interferences observed with immunological methods. Methods: Serum samples with d7 -aldosterone as internal standard were extracted with methyl tert-butyl ether, using liquid-liquid extraction (LLE). Chromatographic separation was performed on a C18 reverse phase column with a methanol-water gradient containing ammonium fluoride. Aldosterone detection was performed on an Agilent 6490 triple quadrupole using electro spray ionisation in positive mode. Results: Multiple reaction monitoring transitions were m/z 361.2–315.1 for aldosterone, and 368.5–323.3 for d7 -aldosterone. Chromatographic retention time was 2.7 min. The method's total CVs at aldosterone concentrations of 45.4 and 1080 pmol/L were 7.0% and 4.8%, respectively. The intra-assay CVs at concentrations of 60.0 and 637 pmol/L were 4.0% and 2.6%, respectively. The method's LOQ and LOD were 10 and 5 pmol/L, respectively, demonstrating an excellent analytical sensitivity. The upper limit of quantification was set to 5000 pmol/L, corresponding to the highest calibrator concentration. The long-term stability of the method was evident from repeated measurements of external control pools from UKNEQAS over a period of aboutAbstract: Background: Accurate quantification of aldosterone is essential in the diagnosis of primary aldosteronism. Liquid chromatography-tandem mass spectrometry (LC-MSMS) analysis is increasingly being used to improve analytical sensitivity and specificity, since this technology reduces most of the interferences observed with immunological methods. Methods: Serum samples with d7 -aldosterone as internal standard were extracted with methyl tert-butyl ether, using liquid-liquid extraction (LLE). Chromatographic separation was performed on a C18 reverse phase column with a methanol-water gradient containing ammonium fluoride. Aldosterone detection was performed on an Agilent 6490 triple quadrupole using electro spray ionisation in positive mode. Results: Multiple reaction monitoring transitions were m/z 361.2–315.1 for aldosterone, and 368.5–323.3 for d7 -aldosterone. Chromatographic retention time was 2.7 min. The method's total CVs at aldosterone concentrations of 45.4 and 1080 pmol/L were 7.0% and 4.8%, respectively. The intra-assay CVs at concentrations of 60.0 and 637 pmol/L were 4.0% and 2.6%, respectively. The method's LOQ and LOD were 10 and 5 pmol/L, respectively, demonstrating an excellent analytical sensitivity. The upper limit of quantification was set to 5000 pmol/L, corresponding to the highest calibrator concentration. The long-term stability of the method was evident from repeated measurements of external control pools from UKNEQAS over a period of about 3 years, showing CVs between 2.0 and 7.0%. Conclusions: We have described a precise, sensitive and stable LC-MSMS method for the measurement of serum aldosterone. In addition, due to the use of LLE and a short LC-column, the method is simple to perform, with a short chromatographic run time. … (more)
- Is Part Of:
- Scandinavian journal of clinical & laboratory investigation. Volume 78:Number 5(2018)
- Journal:
- Scandinavian journal of clinical & laboratory investigation
- Issue:
- Volume 78:Number 5(2018)
- Issue Display:
- Volume 78, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 78
- Issue:
- 5
- Issue Sort Value:
- 2018-0078-0005-0000
- Page Start:
- 379
- Page End:
- 385
- Publication Date:
- 2018-07-04
- Subjects:
- Chromatography -- steroid hormones -- aldosteronism -- ESI-positive mode
Clinical biochemistry -- Periodicals
Physiology, Pathological -- Periodicals
Physiology, Experimental -- Periodicals
Medicine -- Research -- Periodicals
Clinical medicine -- Periodicals
616.0072 - Journal URLs:
- http://informahealthcare.com/loi/clb ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/00365513.2018.1480060 ↗
- Languages:
- English
- ISSNs:
- 0036-5513
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8087.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11763.xml