Feasibility Studies of an Insulin-Only Bionic Pancreas in a Home-Use Setting. (November 2019)
- Record Type:
- Journal Article
- Title:
- Feasibility Studies of an Insulin-Only Bionic Pancreas in a Home-Use Setting. (November 2019)
- Main Title:
- Feasibility Studies of an Insulin-Only Bionic Pancreas in a Home-Use Setting
- Authors:
- Ekhlaspour, Laya
Nally, Laura M.
El-Khatib, Firas H.
Ly, Trang T.
Clinton, Paula
Frank, Eliana
Tanenbaum, Molly L.
Hanes, Sarah J.
Selagamsetty, Rajendranath R.
Hood, Korey
Damiano, Edward R.
Buckingham, Bruce A. - Abstract:
- Background: We tested the safety and performance of the "insulin-only" configuration of the bionic pancreas (BP) closed-loop blood-glucose control system in a home-use setting to assess glycemic outcomes using different static and dynamic glucose set-points. Method: This is an open-label non-randomized study with three consecutive intervention periods. Participants had consecutive weeks of usual care followed by the insulin-only BP with (1) an individualized static set-point of 115 or 130 mg/dL and (2) a dynamic set-point that automatically varied within 110 to 130 mg/dL, depending on hypoglycemic risk. Human factors (HF) testing was conducted using validated surveys. The last five days of each study arm were used for data analysis. Results: Thirteen participants were enrolled with a mean age of 28 years, mean A1c of 7.2%, and mean daily insulin dose of 0.6 U/kg (0.4-1.0 U/kg). The usual care arm had an average glucose of 145 ± 20 mg/dL, which increased in the static set-point arm (159 ± 8 mg/dL, P = .004) but not in the dynamic set-point arm (154 ± 10 mg/dL, P = ns). There was no significant difference in time spent in range (70-180 mg/dL) among the three study arms. There was less time <70 mg/dL with both the static (1.8% ± 1.4%, P = .009) and dynamic set-point (2.7±1.5, P = .051) arms compared to the usual-care arm (5.5% ± 4.2%). HF testing demonstrated preliminary user satisfaction and no increased risk of diabetes burden or distress. Conclusions: The insulin-onlyBackground: We tested the safety and performance of the "insulin-only" configuration of the bionic pancreas (BP) closed-loop blood-glucose control system in a home-use setting to assess glycemic outcomes using different static and dynamic glucose set-points. Method: This is an open-label non-randomized study with three consecutive intervention periods. Participants had consecutive weeks of usual care followed by the insulin-only BP with (1) an individualized static set-point of 115 or 130 mg/dL and (2) a dynamic set-point that automatically varied within 110 to 130 mg/dL, depending on hypoglycemic risk. Human factors (HF) testing was conducted using validated surveys. The last five days of each study arm were used for data analysis. Results: Thirteen participants were enrolled with a mean age of 28 years, mean A1c of 7.2%, and mean daily insulin dose of 0.6 U/kg (0.4-1.0 U/kg). The usual care arm had an average glucose of 145 ± 20 mg/dL, which increased in the static set-point arm (159 ± 8 mg/dL, P = .004) but not in the dynamic set-point arm (154 ± 10 mg/dL, P = ns). There was no significant difference in time spent in range (70-180 mg/dL) among the three study arms. There was less time <70 mg/dL with both the static (1.8% ± 1.4%, P = .009) and dynamic set-point (2.7±1.5, P = .051) arms compared to the usual-care arm (5.5% ± 4.2%). HF testing demonstrated preliminary user satisfaction and no increased risk of diabetes burden or distress. Conclusions: The insulin-only configuration of the BP using either static or dynamic set-points and initialized only with body weight performed similarly to other published insulin-only systems. … (more)
- Is Part Of:
- Journal of diabetes science and technology. Volume 13:Number 6(2019:Nov.)
- Journal:
- Journal of diabetes science and technology
- Issue:
- Volume 13:Number 6(2019:Nov.)
- Issue Display:
- Volume 13, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 13
- Issue:
- 6
- Issue Sort Value:
- 2019-0013-0006-0000
- Page Start:
- 1001
- Page End:
- 1007
- Publication Date:
- 2019-11
- Subjects:
- type 1 diabetes -- artificial pancreas -- closed-loop system -- bionic pancreas
Diabetes -- Periodicals
Medical technology -- Periodicals
Diabetes Mellitus -- Periodicals
616.462005 - Journal URLs:
- http://ejournals.ebsco.com/direct.asp?JournalID=712321 ↗
http://www.jodsat.org/about.html ↗
http://online.sagepub.com/ ↗ - DOI:
- 10.1177/1932296819872225 ↗
- Languages:
- English
- ISSNs:
- 1932-2968
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11732.xml