Analytical method regarding compression-bending capacity of segmental joints: Theoretical model and verification. (November 2019)
- Record Type:
- Journal Article
- Title:
- Analytical method regarding compression-bending capacity of segmental joints: Theoretical model and verification. (November 2019)
- Main Title:
- Analytical method regarding compression-bending capacity of segmental joints: Theoretical model and verification
- Authors:
- Zhang, Li
Feng, Kun
Li, Maoran
Sun, Yuping
He, Chuan
Xiao, Mingqing - Abstract:
- Highlights: Propose an analytical method for calculating the compression-bending capacity of segmental joint. Design an algorithm and verify its accuracy with full-scale segmental joint compression-bending tests. Regarding the concrete yielding of joint surface as a sign of joint ultimate limit state. Joint failure has a vital impact on the structural failure of a straight-jointed assembly structure. Abstract: The flexural bearing capacity of a segmental lining structure, mainly comprising the flexural bearing capacities of segments and the compression-bending capacities of joints, is an important index for evaluating the mechanical performance of a shield tunnel. As indicated by this study, the flexural bearing capacity of a segment has a theoretical basis for the calculation, whereas that of a joint does not. Combined with the deformation characteristics of a segmental joint under compression-bending loads, concrete yielding at the joint surface is taken as the criterion of the ultimate bearing state of a segmental joint, upon which a set of theories for calculating the compression-bending capacity of the segmental joint is established in terms of the mechanical model of the segmental joint. Therefore, according to an analytical solution of compression-bending capacity of a segmental joint, the accuracy and correctness of the designed algorithm are verified through a full-scale compression-bending test of a segmental joint, and the proposed method is then applied toHighlights: Propose an analytical method for calculating the compression-bending capacity of segmental joint. Design an algorithm and verify its accuracy with full-scale segmental joint compression-bending tests. Regarding the concrete yielding of joint surface as a sign of joint ultimate limit state. Joint failure has a vital impact on the structural failure of a straight-jointed assembly structure. Abstract: The flexural bearing capacity of a segmental lining structure, mainly comprising the flexural bearing capacities of segments and the compression-bending capacities of joints, is an important index for evaluating the mechanical performance of a shield tunnel. As indicated by this study, the flexural bearing capacity of a segment has a theoretical basis for the calculation, whereas that of a joint does not. Combined with the deformation characteristics of a segmental joint under compression-bending loads, concrete yielding at the joint surface is taken as the criterion of the ultimate bearing state of a segmental joint, upon which a set of theories for calculating the compression-bending capacity of the segmental joint is established in terms of the mechanical model of the segmental joint. Therefore, according to an analytical solution of compression-bending capacity of a segmental joint, the accuracy and correctness of the designed algorithm are verified through a full-scale compression-bending test of a segmental joint, and the proposed method is then applied to prototype tests of the segmental lining structure for interpretation of the test results. A comparison with the results of full-scale segmental joint tests indicates that the relative errors of the joint bending moments between the test results and the theoretically calculated results are 3% and 5.6% for positive and negative bending, respectively, which not only confirms the accuracy of the proposed theoretical model but also rationalizes the assumption that the yielding of the concrete joint surface is a sign of the joint reaching its ultimate limit state. Using the proposed method, the prototype test results of the segmental rings are interpreted and indicate that the structural failure of a straight-jointed assembly structure (STRS) is mainly caused by joint failure because most of the joints have already exceeded their ultimate bearing capacity, whereas none of the segments have reached their flexural bearing capacity. In the test results for a staggered-jointed assembly structure (STGS), both the segments and joints have reached the ultimate joint bearing capacity or are nearly yielding at the same time. The interaction between the segmental rings of an STGS not only allows both the bearing capacity of the segment and the joint to be fully exerted while the structure bears a load but also generates yielding of the two-part structure almost concurrently; thus, an STGS has better bearing performance than an STRS. … (more)
- Is Part Of:
- Tunnelling and underground space technology. Volume 93(2019)
- Journal:
- Tunnelling and underground space technology
- Issue:
- Volume 93(2019)
- Issue Display:
- Volume 93, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 93
- Issue:
- 2019
- Issue Sort Value:
- 2019-0093-2019-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-11
- Subjects:
- Segmental joint -- Compression-bending capacity -- Theoretical model -- Full-scale test -- Prototype test
Tunneling -- Periodicals
Underground construction -- Periodicals
Tunnels -- Periodicals
Underground areas -- Periodicals
624.193 - Journal URLs:
- http://www.sciencedirect.com/science/journal/08867798 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.tust.2019.103083 ↗
- Languages:
- English
- ISSNs:
- 0886-7798
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9071.405000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11723.xml