Assessment of potential jaw‐tracking advantage using control point sequences of VMAT planning. (6th March 2014)
- Record Type:
- Journal Article
- Title:
- Assessment of potential jaw‐tracking advantage using control point sequences of VMAT planning. (6th March 2014)
- Main Title:
- Assessment of potential jaw‐tracking advantage using control point sequences of VMAT planning
- Authors:
- Kim, Jung‐in
Park, Jong Min
Park, So‐Yeon
Choi, Chang Heon
Wu, Hong‐Gyun
Ye, Sung‐Joon - Abstract:
- Abstract : This study aims to evaluate the potential jaw‐tracking advantage using control point sequences of volume volumetric‐modulated arc therapy (VMAT) planning. VMAT plans for patients with prostate and head and neck (H&N) cancers were converted into new static arc (SA) plans. The SA plan consisted of a series of static fields at each control point of the VMAT plan. All other machine parameters of the SA plan were perfectly identical to those of the original VMAT plan. The jaw‐tracking static arc (JTSA) plans were generated with fields that closed the jaws of each SA field into the multileaf collimators (MLCs) aperture. The dosimetric advantages of JTSA over SA were evaluated in terms of a dose‐volume histogram (DVH) of organ at risk (OAR) after renormalizing both plans to make the same target coverage. Both plans were delivered to the MatriXX‐based COMPASS system for 3D volume dose verification. The average jaw size reduction of the JTSA along the X direction was 3.1 ± 0.9 cm for prostate patients and 6.9 ± 1.9 cm for H&N patients. For prostate patients, the organs far from the target showed larger sparing (3.7%—8.1% on aver‐age) in JTSA than the organs adjacent to the target (1.1%—1.5%). For the H&N plans, the mean dose reductions for all organs ranged from 4.3% to 11.9%. The dose reductions were more significant in the dose regions of D 80, D 90, and D 95 than the dose regions of D 5, D 10, and D 20 for all patients. Likewise, the deliverability andAbstract : This study aims to evaluate the potential jaw‐tracking advantage using control point sequences of volume volumetric‐modulated arc therapy (VMAT) planning. VMAT plans for patients with prostate and head and neck (H&N) cancers were converted into new static arc (SA) plans. The SA plan consisted of a series of static fields at each control point of the VMAT plan. All other machine parameters of the SA plan were perfectly identical to those of the original VMAT plan. The jaw‐tracking static arc (JTSA) plans were generated with fields that closed the jaws of each SA field into the multileaf collimators (MLCs) aperture. The dosimetric advantages of JTSA over SA were evaluated in terms of a dose‐volume histogram (DVH) of organ at risk (OAR) after renormalizing both plans to make the same target coverage. Both plans were delivered to the MatriXX‐based COMPASS system for 3D volume dose verification. The average jaw size reduction of the JTSA along the X direction was 3.1 ± 0.9 cm for prostate patients and 6.9 ± 1.9 cm for H&N patients. For prostate patients, the organs far from the target showed larger sparing (3.7%—8.1% on aver‐age) in JTSA than the organs adjacent to the target (1.1%—1.5%). For the H&N plans, the mean dose reductions for all organs ranged from 4.3% to 11.9%. The dose reductions were more significant in the dose regions of D 80, D 90, and D 95 than the dose regions of D 5, D 10, and D 20 for all patients. Likewise, the deliverability and reproducibility of jaw‐tracking plan were validated. The measured dosimetric advantage of JTSA over SA coincided with the calculated one above. PACS numbers: 87.55.D‐, 87.55.ne … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 15:Number 2(2014)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 15:Number 2(2014)
- Issue Display:
- Volume 15, Issue 2 (2014)
- Year:
- 2014
- Volume:
- 15
- Issue:
- 2
- Issue Sort Value:
- 2014-0015-0002-0000
- Page Start:
- 160
- Page End:
- 168
- Publication Date:
- 2014-03-06
- Subjects:
- VMAT -- jaw tracking -- OAR saving -- dose reduction -- jaw‐tracking static arc plan
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v15i2.4625 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11718.xml