Evaluation of semiempirical VMAT dose reconstruction on a patient dataset based on biplanar diode array measurements. (6th March 2014)
- Record Type:
- Journal Article
- Title:
- Evaluation of semiempirical VMAT dose reconstruction on a patient dataset based on biplanar diode array measurements. (6th March 2014)
- Main Title:
- Evaluation of semiempirical VMAT dose reconstruction on a patient dataset based on biplanar diode array measurements
- Authors:
- Stambaugh, Cassandra
Opp, Daniel
Wassrman, Stuart
Zhang, Geoffrey
Feygelman, Vladimir - Abstract:
- Abstract : We report the results of a preclinical evaluation of recently introduced commercial tools for 3D patient IMRT/VMAT dose reconstruction, the Delta 4 Anatomy calculation algorithm. Based on the same initial measurement, volumetric dose can be reconstructed in two ways. Three‐dimensional dose on the Delta 4 phantom can be obtained by renormalizing the planned dose distribution by the measurement values (D4 Interpolation). Alternatively, incident fluence can be approximated from the phantom measurement and used for volumetric dose calculation on an arbitrary (patient) dataset with a pencil beam algorithm (Delta 4 PB). The primary basis for comparison was 3D dose obtained by previously validated measurement‐guided planned dose perturbation method (ACPDP), based on the ArcCHECK dosimeter with 3DVH software. For five clinical VMAT plans, D4 Interpolation agreed well with ACPDP on a homogeneous cylindrical phantom according to gamma analysis with local dose‐error normalization. The average agreement rates were 98.2 % ± 1.3 % (1 SD), (range 97.0%‐100%) and 92.8 % ± 3.9 % (89.5%‐99.2%), for the 3 % / 3 mm and 2 % / 2 mm criteria, respectively. On a similar geometric phantom, D4 PB demonstrated substantially lower agreement rates with ACPDP: 88.6 % ± 6.8 % (81.2%‐96.1%) and 72.4 % ± 8.4 % (62.1%‐81.1%), for 3 % / 3 mm and 2 % / 2 mm, respectively. The average agreement rates on the heterogeneous patients' CT datasets are lower yet: 81.2 % ± 8.6 % (70.4%‐90.4%) andAbstract : We report the results of a preclinical evaluation of recently introduced commercial tools for 3D patient IMRT/VMAT dose reconstruction, the Delta 4 Anatomy calculation algorithm. Based on the same initial measurement, volumetric dose can be reconstructed in two ways. Three‐dimensional dose on the Delta 4 phantom can be obtained by renormalizing the planned dose distribution by the measurement values (D4 Interpolation). Alternatively, incident fluence can be approximated from the phantom measurement and used for volumetric dose calculation on an arbitrary (patient) dataset with a pencil beam algorithm (Delta 4 PB). The primary basis for comparison was 3D dose obtained by previously validated measurement‐guided planned dose perturbation method (ACPDP), based on the ArcCHECK dosimeter with 3DVH software. For five clinical VMAT plans, D4 Interpolation agreed well with ACPDP on a homogeneous cylindrical phantom according to gamma analysis with local dose‐error normalization. The average agreement rates were 98.2 % ± 1.3 % (1 SD), (range 97.0%‐100%) and 92.8 % ± 3.9 % (89.5%‐99.2%), for the 3 % / 3 mm and 2 % / 2 mm criteria, respectively. On a similar geometric phantom, D4 PB demonstrated substantially lower agreement rates with ACPDP: 88.6 % ± 6.8 % (81.2%‐96.1%) and 72.4 % ± 8.4 % (62.1%‐81.1%), for 3 % / 3 mm and 2 % / 2 mm, respectively. The average agreement rates on the heterogeneous patients' CT datasets are lower yet: 81.2 % ± 8.6 % (70.4%‐90.4%) and 64.6 % ± 8.4 % (56.5%‐74.7%), respectively, for the same two criteria sets. For both threshold combinations, matched analysis of variance (ANOVA) multiple comparisons showed statistically significant differences in mean agreement rates ( p < 0.05 ) for D4 Interpolation versus ACPDP on one hand, and D4 PB versus ACPDP on either cylindrical or patient dataset on the other hand. Based on the favorable D4 Interpolation results for VMAT plans, the resolution of the reconstruction method rather than hardware design is likely to be responsible for D4 PB limitations. PACS number: 87.55Qr … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 15:Number 2(2014)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 15:Number 2(2014)
- Issue Display:
- Volume 15, Issue 2 (2014)
- Year:
- 2014
- Volume:
- 15
- Issue:
- 2
- Issue Sort Value:
- 2014-0015-0002-0000
- Page Start:
- 169
- Page End:
- 180
- Publication Date:
- 2014-03-06
- Subjects:
- VMAT QA -- diode array -- measurement‐guided dose reconstruction -- patient dose reconstruction
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v15i2.4705 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11718.xml