Evaluation of a commercial cardiac motion phantom for dual‐energy chest radiography. (6th March 2014)
- Record Type:
- Journal Article
- Title:
- Evaluation of a commercial cardiac motion phantom for dual‐energy chest radiography. (6th March 2014)
- Main Title:
- Evaluation of a commercial cardiac motion phantom for dual‐energy chest radiography
- Authors:
- Hsieh, Ching‐Yi
Gladish, Gregory
Willis, Charles E. - Abstract:
- Abstract : Misregistration due to cardiac motion causes artifacts in two‐exposure dual‐energy subtraction images, in both the soft‐tissue‐only image and the bone‐only image. Two previous investigations have attempted to avoid misregistration artifacts by using cardiac gating of the first and second exposures. The severity of misregistration was affected by the heart rate, the time interval between the low‐ and high‐energy exposures, the total duration of the two exposures, and the phase of the cardiac cycle at the start of the exposure sequence. We sought to determine whether a commercial phantom with a simulated beating heart can be use to investigate the factors affecting misregistration in dual‐energy chest radiography. We made dual‐energy images of the phantom in postero–anterior orientation using the indirect digital radiography system (GE XQ/i). We acquired digital images at heart rates between 40 beats per minute and 120 beats per minute and transferred them to a computer, where the area of the artifact on the silhouette of the heart was measured from both soft‐tissue‐only and bone‐only images. For comparison, we measured misregistration in clinical dual‐energy subtraction images by the same method. Generally speaking, without synchronization of the exposure sequence with the cardiac cycle, the area of the misregistration artifact increased with heart rate for both the phantom and clinical images. However, the phantom exaggerated the magnitude of misregistrationAbstract : Misregistration due to cardiac motion causes artifacts in two‐exposure dual‐energy subtraction images, in both the soft‐tissue‐only image and the bone‐only image. Two previous investigations have attempted to avoid misregistration artifacts by using cardiac gating of the first and second exposures. The severity of misregistration was affected by the heart rate, the time interval between the low‐ and high‐energy exposures, the total duration of the two exposures, and the phase of the cardiac cycle at the start of the exposure sequence. We sought to determine whether a commercial phantom with a simulated beating heart can be use to investigate the factors affecting misregistration in dual‐energy chest radiography. We made dual‐energy images of the phantom in postero–anterior orientation using the indirect digital radiography system (GE XQ/i). We acquired digital images at heart rates between 40 beats per minute and 120 beats per minute and transferred them to a computer, where the area of the artifact on the silhouette of the heart was measured from both soft‐tissue‐only and bone‐only images. For comparison, we measured misregistration in clinical dual‐energy subtraction images by the same method. Generally speaking, without synchronization of the exposure sequence with the cardiac cycle, the area of the misregistration artifact increased with heart rate for both the phantom and clinical images. However, the phantom exaggerated the magnitude of misregistration relative to clinical images. Although this phantom was designed for horizontal operation and computed tomography imaging, it can be use in an upright configuration to simulate heart motion for investigation of dual‐energy misregistration artifacts and control. PACS numbers: 87.59.bf, 87.57.cf, 87.57N … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 15:Number 2(2014)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 15:Number 2(2014)
- Issue Display:
- Volume 15, Issue 2 (2014)
- Year:
- 2014
- Volume:
- 15
- Issue:
- 2
- Issue Sort Value:
- 2014-0015-0002-0000
- Page Start:
- 235
- Page End:
- 251
- Publication Date:
- 2014-03-06
- Subjects:
- dual‐energy subtraction chest radiography -- misregistration -- cardiac motion phantom -- heart rate -- ejection fraction
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v15i2.4508 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11718.xml