Weber-Carstens, S. - Abstract:
- Summary: Purpose: Indirect calorimetry (IC) is the gold standard for measuring energy expenditure (EE). Due to O2 uptake and CO2 removal by both the extracorporeal lung support (ECLS) membrane and the lungs, a conventional IC is not feasible and no data available. Our MEEP (Measuring Energy Expenditure in ECLS Patients) protocol enables the determination of the REE in patients with ECLS, the comparison to patients without ECLS, and accuracy assessment of estimating equations. Methods: In the MEEP protocol, a conventional IC is performed and extended by a calculation of the O2 uptake and the CO2 elimination by the ECLS membrane. Sum O2 uptake and CO2 elimination were used in the equation of Weir to calculate EE. We included 20 patients with ARDS on veno-venous (vv)-extracorporeal membrane oxygenation (ECMO) treatment, and 20 matched ARDS patients without ECLS as control. EE measurements were compared to the most prevalent predicting equations for EE. Results: The new MEEP-protocol was shown to be feasible. None of the estimating equations matched the measured EE. Measured EE values did not significantly differ between the ARDS patients with vv-ECMO (2013 kcal/d [1786/2333]) and ARDS patients without ECLS (1857 kcal/d [1602/2085]) (p = 0.165). The blood flow through the vv-ECMO itself did not influence the EE. Conclusion: Using the MEEP protocol, EE becomes easily measurable in patients with ECLS. We recommend the implementation of sequential measurements of EE in theSummary: Purpose: Indirect calorimetry (IC) is the gold standard for measuring energy expenditure (EE). Due to O2 uptake and CO2 removal by both the extracorporeal lung support (ECLS) membrane and the lungs, a conventional IC is not feasible and no data available. Our MEEP (Measuring Energy Expenditure in ECLS Patients) protocol enables the determination of the REE in patients with ECLS, the comparison to patients without ECLS, and accuracy assessment of estimating equations. Methods: In the MEEP protocol, a conventional IC is performed and extended by a calculation of the O2 uptake and the CO2 elimination by the ECLS membrane. Sum O2 uptake and CO2 elimination were used in the equation of Weir to calculate EE. We included 20 patients with ARDS on veno-venous (vv)-extracorporeal membrane oxygenation (ECMO) treatment, and 20 matched ARDS patients without ECLS as control. EE measurements were compared to the most prevalent predicting equations for EE. Results: The new MEEP-protocol was shown to be feasible. None of the estimating equations matched the measured EE. Measured EE values did not significantly differ between the ARDS patients with vv-ECMO (2013 kcal/d [1786/2333]) and ARDS patients without ECLS (1857 kcal/d [1602/2085]) (p = 0.165). The blood flow through the vv-ECMO itself did not influence the EE. Conclusion: Using the MEEP protocol, EE becomes easily measurable in patients with ECLS. We recommend the implementation of sequential measurements of EE in the critically ill, especially for patients with ECLS, but also for those without, in order to improve goal directed nourishment. … (more)
- Is Part Of:
- Clinical nutrition. Volume 37:Issue 1(2018)
- Journal:
- Clinical nutrition
- Issue:
- Volume 37:Issue 1(2018)
- Issue Display:
- Volume 37, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 37
- Issue:
- 1
- Issue Sort Value:
- 2018-0037-0001-0000
- Page Start:
- 301
- Page End:
- 307
- Publication Date:
- 2018-02
- Subjects:
- Energy expenditure -- Calorimetry -- Indirect -- Extracorporeal membrane oxygenation -- ECLS -- Metabolism
MEEP Measuring Energy expenditure in Extracorporeal lung Support Patients -- IC Indirect calorimetry -- EE Energy expenditure -- ARDS Acute respiratory distress syndrome -- ECLS Extracorporeal lung support -- ECMO Extracorporeal Membrane Oxygenation -- vv veno-venous -- BGA Blood Gas Analyses -- HB1919 Harris Benedict 1919 -- HB1984 Harris Benedict 1984 -- ACCP American College of Chest Physicians -- ESICM European Society of Intensive Care Medicine -- IQR Inter quartile range -- A.S.P.E.N. American Society for Parenteral and Enteral Nutrition -- E.S.P.E.N. European Society for Clinical Nutrition and Metabolism
Critically ill -- Nutrition -- Periodicals
Diet therapy -- Periodicals
Parenteral feeding -- Periodicals
Enteral feeding -- Periodicals
Enteral Nutrition -- Periodicals
Parenteral Nutrition -- Periodicals
Metabolism -- Periodicals
Diétothérapie -- Périodiques
Alimentation parentérale -- Périodiques
Alimentation entérale -- Périodiques
Nutrition -- Périodiques
Diet therapy
Enteral feeding
Nutrition
Parenteral feeding
Electronic journals
Periodicals
Electronic journals
615.854 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02615614 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clnu.2017.01.001 ↗
- Languages:
- English
- ISSNs:
- 0261-5614
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.314500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11719.xml