Device Therapies Among Patients Receiving Primary Prevention Implantable Cardioverter‐Defibrillators in the Cardiovascular Research Network. Issue 7 (26th March 2018)
- Record Type:
- Journal Article
- Title:
- Device Therapies Among Patients Receiving Primary Prevention Implantable Cardioverter‐Defibrillators in the Cardiovascular Research Network. Issue 7 (26th March 2018)
- Main Title:
- Device Therapies Among Patients Receiving Primary Prevention Implantable Cardioverter‐Defibrillators in the Cardiovascular Research Network
- Authors:
- Greenlee, Robert T.
Go, Alan S.
Peterson, Pamela N.
Cassidy‐Bushrow, Andrea E.
Gaber, Charles
Garcia‐Montilla, Romel
Glenn, Karen A.
Gupta, Nigel
Gurwitz, Jerry H.
Hammill, Stephen C.
Hayes, John J.
Kadish, Alan
Magid, David J.
McManus, David D.
Multerer, Deborah
Powers, J. David
Reifler, Liza M.
Reynolds, Kristi
Schuger, Claudio
Sharma, Param P.
Smith, David H.
Suits, Mary
Sung, Sue Hee
Varosy, Paul D.
Vidaillet, Humberto J.
Masoudi, Frederick A. - Abstract:
- Abstract : Background: Primary prevention implantable cardioverter‐defibrillators (ICDs) reduce mortality in selected patients with left ventricular systolic dysfunction by delivering therapies (antitachycardia pacing or shocks) to terminate potentially lethal arrhythmias; inappropriate therapies also occur. We assessed device therapies among adults receiving primary prevention ICDs in 7 healthcare systems. Methods and Results: We linked medical record data, adjudicated device therapies, and the National Cardiovascular Data Registry ICD Registry. Survival analysis evaluated therapy probability and predictors after ICD implant from 2006 to 2009, with attention to Centers for Medicare and Medicaid Services Coverage With Evidence Development subgroups: left ventricular ejection fraction, 31% to 35%; nonischemic cardiomyopathy <9 months' duration; and New York Heart Association class IV heart failure with cardiac resynchronization therapy defibrillator. Among 2540 patients, 35% were <65 years old, 26% were women, and 59% were white. During 27 (median) months, 738 (29%) received ≥1 therapy. Three‐year therapy risk was 36% (appropriate, 24%; inappropriate, 12%). Appropriate therapy was more common in men (adjusted hazard ratio [HR], 1.84; 95% confidence interval [CI], 1.43–2.35). Inappropriate therapy was more common in patients with atrial fibrillation (adjusted HR, 2.20; 95% CI, 1.68–2.87), but less common among patients ≥65 years old versus younger (adjusted HR, 0.72; 95% CI,Abstract : Background: Primary prevention implantable cardioverter‐defibrillators (ICDs) reduce mortality in selected patients with left ventricular systolic dysfunction by delivering therapies (antitachycardia pacing or shocks) to terminate potentially lethal arrhythmias; inappropriate therapies also occur. We assessed device therapies among adults receiving primary prevention ICDs in 7 healthcare systems. Methods and Results: We linked medical record data, adjudicated device therapies, and the National Cardiovascular Data Registry ICD Registry. Survival analysis evaluated therapy probability and predictors after ICD implant from 2006 to 2009, with attention to Centers for Medicare and Medicaid Services Coverage With Evidence Development subgroups: left ventricular ejection fraction, 31% to 35%; nonischemic cardiomyopathy <9 months' duration; and New York Heart Association class IV heart failure with cardiac resynchronization therapy defibrillator. Among 2540 patients, 35% were <65 years old, 26% were women, and 59% were white. During 27 (median) months, 738 (29%) received ≥1 therapy. Three‐year therapy risk was 36% (appropriate, 24%; inappropriate, 12%). Appropriate therapy was more common in men (adjusted hazard ratio [HR], 1.84; 95% confidence interval [CI], 1.43–2.35). Inappropriate therapy was more common in patients with atrial fibrillation (adjusted HR, 2.20; 95% CI, 1.68–2.87), but less common among patients ≥65 years old versus younger (adjusted HR, 0.72; 95% CI, 0.54–0.95) and in recent implants (eg, in 2009 versus 2006; adjusted HR, 0.66; 95% CI, 0.46–0.95). In Centers for Medicare and Medicaid Services Coverage With Evidence Development analysis, inappropriate therapy was less common with cardiac resynchronization therapy defibrillator versus single chamber (adjusted HR, 0.55; 95% CI, 0.36–0.84); therapy risk did not otherwise differ for Centers for Medicare and Medicaid Services Coverage With Evidence Development subgroups. Conclusions: In this community cohort of primary prevention patients receiving ICD, therapy delivery varied across demographic and clinical characteristics, but did not differ meaningfully for Centers for Medicare and Medicaid Services Coverage With Evidence Development subgroups. … (more)
- Is Part Of:
- Journal of the American Heart Association. Volume 7:Issue 7(2018)
- Journal:
- Journal of the American Heart Association
- Issue:
- Volume 7:Issue 7(2018)
- Issue Display:
- Volume 7, Issue 7 (2018)
- Year:
- 2018
- Volume:
- 7
- Issue:
- 7
- Issue Sort Value:
- 2018-0007-0007-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2018-03-26
- Subjects:
- arrhythmia -- implantable cardioverter‐defibrillator -- inappropriate shock -- outcomes research -- sudden cardiac death
Heart -- Diseases -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
Cerebrovascular disease -- Periodicals
Cardiology -- Periodicals
616.1 - Journal URLs:
- http://jaha.ahajournals.org ↗
http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2047-9980 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1161/JAHA.117.008292 ↗
- Languages:
- English
- ISSNs:
- 2047-9980
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11717.xml