A novel sensing platform based on ionic liquid integrated carboxylic-functionalized graphene oxide nanosheets for honokiol determination. (10th February 2015)
- Record Type:
- Journal Article
- Title:
- A novel sensing platform based on ionic liquid integrated carboxylic-functionalized graphene oxide nanosheets for honokiol determination. (10th February 2015)
- Main Title:
- A novel sensing platform based on ionic liquid integrated carboxylic-functionalized graphene oxide nanosheets for honokiol determination
- Authors:
- Zhang, Shenghui
Chen, Xuemin
Liu, Guishen
Hou, Xiaodong
Huang, Yina
Chen, Jianpeng
Zhan, Guoqing
Li, Chunya - Abstract:
- Graphical abstract: Highlights: Piperidinium based ionic liquid bearing pyrrole was synthesized. Ionic liquid integrated graphene oxide nanocompisite was fabricated. Polymerized ionic liquid-graphene oxide film electrode was prepared. The film electrode exhibits high sensitivity towards honokiol and magnolol. Stimulate determination of honokiol and magnolol was fulfilled. Abstract: A novel ionic liquid, 4-hydroxy-1-methyl-[1-(3-pyrrolyl-propyl)]-piperidinium bromide, was synthesized and characterized. Carboxylic-functionalized graphene oxide nanosheets were modified with this ionic liquid to fabricate a nanocomposite which was denoted as GrO-COO-IL. Characterizations of FTIR, X-ray photoelectron spectroscopy, Raman spectroscopy and transmission electron microscopy confirmed the successful conjunction of these two components. GrO-COO-IL nanocomposites were homogeneously dispersed with utralpure water, and were then coated onto glassy carbon electrode surface. Followed by cyclic voltammetric scanning, a graphene oxide-polymerized ionic liquid film modified electrode (GrO-COO-Poly-IL/GCE) was prepared, and was studied with electrochemical impedance spectroscopy and scanning electron microscope. It was found that both honokiol and magnolol exhibit sensitive voltammetric response at the GrO-COO-Poly-IL/GCE. Simultaneous assay of honokiol and magnolol was realized with differential pulse voltametry. In the presence of magnolol, the oxidation peak current was linearly related toGraphical abstract: Highlights: Piperidinium based ionic liquid bearing pyrrole was synthesized. Ionic liquid integrated graphene oxide nanocompisite was fabricated. Polymerized ionic liquid-graphene oxide film electrode was prepared. The film electrode exhibits high sensitivity towards honokiol and magnolol. Stimulate determination of honokiol and magnolol was fulfilled. Abstract: A novel ionic liquid, 4-hydroxy-1-methyl-[1-(3-pyrrolyl-propyl)]-piperidinium bromide, was synthesized and characterized. Carboxylic-functionalized graphene oxide nanosheets were modified with this ionic liquid to fabricate a nanocomposite which was denoted as GrO-COO-IL. Characterizations of FTIR, X-ray photoelectron spectroscopy, Raman spectroscopy and transmission electron microscopy confirmed the successful conjunction of these two components. GrO-COO-IL nanocomposites were homogeneously dispersed with utralpure water, and were then coated onto glassy carbon electrode surface. Followed by cyclic voltammetric scanning, a graphene oxide-polymerized ionic liquid film modified electrode (GrO-COO-Poly-IL/GCE) was prepared, and was studied with electrochemical impedance spectroscopy and scanning electron microscope. It was found that both honokiol and magnolol exhibit sensitive voltammetric response at the GrO-COO-Poly-IL/GCE. Simultaneous assay of honokiol and magnolol was realized with differential pulse voltametry. In the presence of magnolol, the oxidation peak current was linearly related to honokiol concentration in the range of 1.0 × 10 −8 ∼ 1.0 × 10 −5 mol L −1 with a detection limit of 1.53 × 10 −9 mol L −1 (S/N = 3). Meanwhile, in the presence of honokiol, a linear relationship between the oxidation peak current and magnolol concentration was found from 7.0 × 10 −8 to 1.0 × 10 −5 mol L −1 . The detection limit is calculated to be 8.27 × 10 −9 mol L −1 (S/N = 3). In addition, GrO-COO-Poly-IL/GCE was successfully used for determination of honokiol in the traditional Chinese medicine, and was demonstrated to be an effective and sensitive method. … (more)
- Is Part Of:
- Electrochimica acta. Volume 155(2015)
- Journal:
- Electrochimica acta
- Issue:
- Volume 155(2015)
- Issue Display:
- Volume 155, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 155
- Issue:
- 2015
- Issue Sort Value:
- 2015-0155-2015-0000
- Page Start:
- 45
- Page End:
- 53
- Publication Date:
- 2015-02-10
- Subjects:
- Ionic liquid -- Graphene oxide -- Honokiol -- Magnolol -- Voltammetry
Electrochemistry -- Periodicals
Electrochemistry, Industrial -- Periodicals
541.37 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00134686 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.electacta.2014.12.085 ↗
- Languages:
- English
- ISSNs:
- 0013-4686
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3698.950000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: