Pulmonary Capillary Hemorrhage Induced by Acoustic Radiation Force Impulse Shear Wave Elastography in Ventilated Rats. (31st January 2019)
- Record Type:
- Journal Article
- Title:
- Pulmonary Capillary Hemorrhage Induced by Acoustic Radiation Force Impulse Shear Wave Elastography in Ventilated Rats. (31st January 2019)
- Main Title:
- Pulmonary Capillary Hemorrhage Induced by Acoustic Radiation Force Impulse Shear Wave Elastography in Ventilated Rats
- Authors:
- Miller, Douglas L.
Dong, Zhihong
Dou, Chunyan
Patterson, Brandon
Raghavendran, Krishnan - Abstract:
- Abstract : Objectives: Diagnostic ultrasound (DUS) imaging can induce pulmonary capillary hemorrhage (PCH), possibly related to the ultrasonic radiation surface pressure arising from reflection at the lung blood‐air interfaces. Acoustic radiation force impulse (ARFI) elastography is a relatively new DUS mode with high‐energy "push pulses" used to move tissue and generate shear waves. The objective of this study was to characterize PCH induced by the ARFI elastographic mode for comparison with other previously tested DUS modes. Methods: Pulmonary capillary hemorrhage induction was examined for ARFI elastographic frames with 5.7‐MHz push pulses (Acuson S3000; Siemens Medical Solutions, Mountain View, CA), which had a derated PRPA of 2.6 MPa. Groups of rats with tracheal tube placement had no ventilation (spontaneous breathing), intermittent positive pressure ventilation (IPPV), or IPPV plus 8 cm H2 O of positive end‐expiratory pressure (PEEP). Exposure was to 1 or 20 manually triggered image frame acquisitions. The PCH area was measured on the lung surface. Results: All 20‐frame exposure groups, and even the single‐frame group, had significant PCH relative to shams. Single‐frame exposures produced significantly less PCH ( P = .002) than 20‐frame exposures in rats with a tracheal tube only (spontaneous breathing). The PEEP inhibited the PCH and produced about half of the PCH area induced for IPPV without PEEP ( P = .014). Conclusions: The PCH results were comparable withAbstract : Objectives: Diagnostic ultrasound (DUS) imaging can induce pulmonary capillary hemorrhage (PCH), possibly related to the ultrasonic radiation surface pressure arising from reflection at the lung blood‐air interfaces. Acoustic radiation force impulse (ARFI) elastography is a relatively new DUS mode with high‐energy "push pulses" used to move tissue and generate shear waves. The objective of this study was to characterize PCH induced by the ARFI elastographic mode for comparison with other previously tested DUS modes. Methods: Pulmonary capillary hemorrhage induction was examined for ARFI elastographic frames with 5.7‐MHz push pulses (Acuson S3000; Siemens Medical Solutions, Mountain View, CA), which had a derated PRPA of 2.6 MPa. Groups of rats with tracheal tube placement had no ventilation (spontaneous breathing), intermittent positive pressure ventilation (IPPV), or IPPV plus 8 cm H2 O of positive end‐expiratory pressure (PEEP). Exposure was to 1 or 20 manually triggered image frame acquisitions. The PCH area was measured on the lung surface. Results: All 20‐frame exposure groups, and even the single‐frame group, had significant PCH relative to shams. Single‐frame exposures produced significantly less PCH ( P = .002) than 20‐frame exposures in rats with a tracheal tube only (spontaneous breathing). The PEEP inhibited the PCH and produced about half of the PCH area induced for IPPV without PEEP ( P = .014). Conclusions: The PCH results were comparable with those from a previous study using B‐mode or color Doppler exposure for 5 minutes; however, these modes delivered many more pulses for continuous imaging frames, suggesting that the ARFI elastographic frames were individually much more effective. … (more)
- Is Part Of:
- Journal of ultrasound in medicine. Volume 38:Number 10(2019)
- Journal:
- Journal of ultrasound in medicine
- Issue:
- Volume 38:Number 10(2019)
- Issue Display:
- Volume 38, Issue 10 (2019)
- Year:
- 2019
- Volume:
- 38
- Issue:
- 10
- Issue Sort Value:
- 2019-0038-0010-0000
- Page Start:
- 2575
- Page End:
- 2587
- Publication Date:
- 2019-01-31
- Subjects:
- comet tail artifact -- diagnostic ultrasound safety -- mechanical index -- mechanical ventilation -- pulmonary diagnostic ultrasound -- ultrasound elastography
Ultrasonics in medicine -- Periodicals
Ultrasonics
Ultrasonography
Ultrasonics in medicine
Electronic journals
Periodicals
Periodicals
616.07543 - Journal URLs:
- http://www.jultrasoundmed.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jum.14950 ↗
- Languages:
- English
- ISSNs:
- 0278-4297
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5071.455000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11693.xml