The hemodynamic effects of a central iliac arteriovenous anastomosis at 6 months in patients with resistant and uncontrolled hypertension. Issue 9 (26th July 2019)
- Record Type:
- Journal Article
- Title:
- The hemodynamic effects of a central iliac arteriovenous anastomosis at 6 months in patients with resistant and uncontrolled hypertension. Issue 9 (26th July 2019)
- Main Title:
- The hemodynamic effects of a central iliac arteriovenous anastomosis at 6 months in patients with resistant and uncontrolled hypertension
- Authors:
- Eysenck, William
van Zalen, Jet
Freemantle, Nick
Lloyd, Guy
Furniss, Stephen
Sulke, Neil - Abstract:
- Abstract: A central iliac arteriovenous anastomosis, termed the "coupler" (ROX Medical), results in a significant reduction in blood pressure (BP) in hypertensive patients. This study assessed functional and hemodynamic changes induced by the device. Twenty‐one patients with resistant and/or uncontrolled hypertension underwent stress echocardiography and cardiopulmonary exercise testing (CPET) at baseline and 6 months post‐coupler implantation. End points were selected to best evaluate cardiac function including Doppler stroke volume (SV), septal and lateral E/E′, and right ventricular systolic velocity S′ (RV S′). CPET VO2 peak demonstrated total cardiopulmonary performance. SV increased from 76.4 SD12.2 mL to 92.1 SD22.7 mL 6 months post‐coupler insertion; P = .002. No changes in RV S′, septal or lateral E/E′, or VO2 peak were observed. Five patients experienced increased diuretic requirement ≥3 times baseline. RV S′ fell from 19.0 SD1.87 cm/s to 16.80 SD3.43 cm/s in these patients ( P > .05). A significant increase in SV 6 months post‐coupler insertion was observed. In patients with increased diuretic requirement, the device was associated with a lower RV S′ suggesting occult RV dysfunction as the mechanism of this pre‐specified adverse outcome.
- Is Part Of:
- Journal of clinical hypertension. Volume 21:Issue 9(2019)
- Journal:
- Journal of clinical hypertension
- Issue:
- Volume 21:Issue 9(2019)
- Issue Display:
- Volume 21, Issue 9 (2019)
- Year:
- 2019
- Volume:
- 21
- Issue:
- 9
- Issue Sort Value:
- 2019-0021-0009-0000
- Page Start:
- 1399
- Page End:
- 1405
- Publication Date:
- 2019-07-26
- Subjects:
- advanced echocardiography -- cardiopulmonary exercise testing -- hypertension -- iliac arteriovenous fistula
Hypertension -- Periodicals
616.132 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1751-7176 ↗
http://onlinelibrary.wiley.com/ ↗
http://www.blackwell-synergy.com/loi/jch ↗ - DOI:
- 10.1111/jch.13646 ↗
- Languages:
- English
- ISSNs:
- 1524-6175
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.484100
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11692.xml