Reliability of, and Agreement Between, two Breath‐by‐Breath Indirect Calorimeters at Varying Levels of Inspiratory Oxygen. (4th February 2019)
- Record Type:
- Journal Article
- Title:
- Reliability of, and Agreement Between, two Breath‐by‐Breath Indirect Calorimeters at Varying Levels of Inspiratory Oxygen. (4th February 2019)
- Main Title:
- Reliability of, and Agreement Between, two Breath‐by‐Breath Indirect Calorimeters at Varying Levels of Inspiratory Oxygen
- Authors:
- Poulsen, Mathias Krogh
Thomsen, Lars Pilegaard
Kjærgaard, Søren
Rees, Stephen Edward
Karbing, Dan Stieper - Abstract:
- Abstract: Background: Indirect calorimetry (IC) is considered the accurate way of measuring energy expenditure (EE). IC devices often apply the Haldane transformation, introducing errors at inspiratory oxygen fraction (FiO2 ) >60%. The aim was to assess measurement reliability and agreement between an unevaluated IC (device 2) (Beacon Caresystem, Mermaid Care A/S, Noerresundby, Denmark) not using Haldane transformation and an IC that does (device 1) (Ecovx, GE, Helsinki, Finland) at varying FiO2 . Methods: Twenty healthy male subjects participated, with 16 completing the study (33 ± 9 years, 83.3 ± 16 kg, 1.83 ± 0.08 m). Subjects were mechanically ventilated in pressure support (3cmH2 O; positive end‐expiratory pressure: 3cmH2 O) at FiO2 of 21%, 50%, 85%, and 21% for 15 minutes at each FiO2 . Mean EE, oxygen consumption (VO2 ), and CO2 production (VCO2 ) were compared within and between devices across FiO2 levels. Results: Device 2 showed within‐device EE significant differences at 21% vs 50% FiO2 and device 1 for VCO2 at 50% vs. 85% FiO2 . For all variables, both devices showed reliable measurements at 21% and 50% FiO2, but at 85%, FiO2 bias and limits of agreement increased. Between devices, there were significant differences for EE at both 21% and 85% FiO2 for VO2 and for VCO2 at 85% FiO2 . Conclusion: Both systems measured EE, VO2, and VCO2 at 21%–85% FiO2 reliably but with bias at 85% FiO2 . The devices were in agreement at 21% and 50% FiO2, but further studies need toAbstract: Background: Indirect calorimetry (IC) is considered the accurate way of measuring energy expenditure (EE). IC devices often apply the Haldane transformation, introducing errors at inspiratory oxygen fraction (FiO2 ) >60%. The aim was to assess measurement reliability and agreement between an unevaluated IC (device 2) (Beacon Caresystem, Mermaid Care A/S, Noerresundby, Denmark) not using Haldane transformation and an IC that does (device 1) (Ecovx, GE, Helsinki, Finland) at varying FiO2 . Methods: Twenty healthy male subjects participated, with 16 completing the study (33 ± 9 years, 83.3 ± 16 kg, 1.83 ± 0.08 m). Subjects were mechanically ventilated in pressure support (3cmH2 O; positive end‐expiratory pressure: 3cmH2 O) at FiO2 of 21%, 50%, 85%, and 21% for 15 minutes at each FiO2 . Mean EE, oxygen consumption (VO2 ), and CO2 production (VCO2 ) were compared within and between devices across FiO2 levels. Results: Device 2 showed within‐device EE significant differences at 21% vs 50% FiO2 and device 1 for VCO2 at 50% vs. 85% FiO2 . For all variables, both devices showed reliable measurements at 21% and 50% FiO2, but at 85%, FiO2 bias and limits of agreement increased. Between devices, there were significant differences for EE at both 21% and 85% FiO2 for VO2 and for VCO2 at 85% FiO2 . Conclusion: Both systems measured EE, VO2, and VCO2 at 21%–85% FiO2 reliably but with bias at 85% FiO2 . The devices were in agreement at 21% and 50% FiO2, but further studies need to confirm accuracy at high FiO2 . … (more)
- Is Part Of:
- Nutrition in clinical practice. Volume 34:Number 5(2019)
- Journal:
- Nutrition in clinical practice
- Issue:
- Volume 34:Number 5(2019)
- Issue Display:
- Volume 34, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 34
- Issue:
- 5
- Issue Sort Value:
- 2019-0034-0005-0000
- Page Start:
- 767
- Page End:
- 774
- Publication Date:
- 2019-02-04
- Subjects:
- bias -- indirect calorimetry -- mechanical ventilation -- reproducibility of results -- resting energy expenditure
Nutrition -- Periodicals
Diet therapy -- Periodicals
Artificial feeding -- Periodicals
615.854 - Journal URLs:
- http://ncp.aspenjournals.org ↗
http://ncp.sagepub.com ↗
http://www.sagepublications.com/ ↗ - DOI:
- 10.1002/ncp.10250 ↗
- Languages:
- English
- ISSNs:
- 0884-5336
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6188.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11679.xml