Implementation of total body photon irradiation as part of an institutional bone marrow transplant program for the treatment of canine lymphoma and leukemias. Issue 5 (30th May 2019)
- Record Type:
- Journal Article
- Title:
- Implementation of total body photon irradiation as part of an institutional bone marrow transplant program for the treatment of canine lymphoma and leukemias. Issue 5 (30th May 2019)
- Main Title:
- Implementation of total body photon irradiation as part of an institutional bone marrow transplant program for the treatment of canine lymphoma and leukemias
- Authors:
- Gieger, Tracy L.
Nolan, Michael W.
Roback, Donald M.
Suter, Steven E. - Abstract:
- Abstract: A total body irradiation (TBI) protocol was developed to support a bone marrow transplant (BMT) program for the treatment of canine hematologic malignancies. The purpose of this prospective study is to describe implementation of the protocol and resultant dosimetry. Nongraphic manual treatment planning using 6 MV photons, isocentric delivery, 40 × 40 cm field size, wall‐mounted lasers to verify positioning, a lucite beam spoiler (without use of bolus material), a dose rate of 8.75 cGy/min at patient isocenter, and a source‐to‐axis distance of 338 cm were used for TBI. A monitor unit calculation formula was derived using ion chamber measurements and a solid water phantom. Five thermoluminescent dosimeters (TLDs) were used at various anatomic locations in each of four cadaver dogs, to verify fidelity of the monitor unit formula prior to clinical implementation. In vivo dosimetric data were then collected with five TLDs at various anatomic locations in six patients treated with TBI. A total dose of 10 Gy divided into two 5 Gy fractions was delivered approximately 16 h apart, immediately followed by autologous stem cell transplant. The mean difference between prescribed and delivered doses ranged from 99% to 109% for various sites in cadavers, and from 83% to 121% in clinical patients. The mean total body dose in cadavers and clinical patients when whole body dose was estimated by averaging doses measured by variably placed TLDs ranged from 98% to 108% and 93% to 102%Abstract: A total body irradiation (TBI) protocol was developed to support a bone marrow transplant (BMT) program for the treatment of canine hematologic malignancies. The purpose of this prospective study is to describe implementation of the protocol and resultant dosimetry. Nongraphic manual treatment planning using 6 MV photons, isocentric delivery, 40 × 40 cm field size, wall‐mounted lasers to verify positioning, a lucite beam spoiler (without use of bolus material), a dose rate of 8.75 cGy/min at patient isocenter, and a source‐to‐axis distance of 338 cm were used for TBI. A monitor unit calculation formula was derived using ion chamber measurements and a solid water phantom. Five thermoluminescent dosimeters (TLDs) were used at various anatomic locations in each of four cadaver dogs, to verify fidelity of the monitor unit formula prior to clinical implementation. In vivo dosimetric data were then collected with five TLDs at various anatomic locations in six patients treated with TBI. A total dose of 10 Gy divided into two 5 Gy fractions was delivered approximately 16 h apart, immediately followed by autologous stem cell transplant. The mean difference between prescribed and delivered doses ranged from 99% to 109% for various sites in cadavers, and from 83% to 121% in clinical patients. The mean total body dose in cadavers and clinical patients when whole body dose was estimated by averaging doses measured by variably placed TLDs ranged from 98% to 108% and 93% to 102% of the prescribed dose, respectively, which was considered acceptable. This protocol could be used for institutional implementation of TBI. … (more)
- Is Part Of:
- Veterinary radiology & ultrasound. Volume 60:Issue 5(2019)
- Journal:
- Veterinary radiology & ultrasound
- Issue:
- Volume 60:Issue 5(2019)
- Issue Display:
- Volume 60, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 60
- Issue:
- 5
- Issue Sort Value:
- 2019-0060-0005-0000
- Page Start:
- 586
- Page End:
- 593
- Publication Date:
- 2019-05-30
- Subjects:
- cadaver -- lymphosarcoma -- myeloablation -- thermoluminescent dosimeter
Veterinary radiology -- Periodicals
Radiologie vétérinaire -- Périodiques
Échographie vétérinaire -- Périodiques
Radiography -- Periodicals
Ultrasonography -- Periodicals
Diagnosis -- Periodicals
Veterinary Medicine -- Periodicals
Societies, Medical -- Periodicals
636.089607 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1740-8261 ↗
http://www.blackwell-synergy.com/loi/vru ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1058-8183;screen=info;ECOIP ↗
http://www.blackwell-synergy.com/loi/vru ↗ - DOI:
- 10.1111/vru.12776 ↗
- Languages:
- English
- ISSNs:
- 1058-8183
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9229.281000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11694.xml