The effect of eyebrow stenting on the measurement of levator excursion in normal and ptotic eyelids. (3rd September 2019)
- Record Type:
- Journal Article
- Title:
- The effect of eyebrow stenting on the measurement of levator excursion in normal and ptotic eyelids. (3rd September 2019)
- Main Title:
- The effect of eyebrow stenting on the measurement of levator excursion in normal and ptotic eyelids
- Authors:
- Yeganeh, Amir
Sinha, Kunal R.
Fell, David
Rootman, Daniel B. - Abstract:
- ABSTRACT: Introduction : Levator function is classically estimated by measuring upper eyelid excursion (ULE) with digital brow stenting. The purpose of this study is to compare ULE with and without brow stenting in normal and ptotic eyelids. Methods : In this prospective observational study, normal and ptotic eyelids were recruited. Subjects were photographed with and without digital brow stenting in primary position, downgaze, and upgaze. Measurements were conducted on digital photographs. The primary outcome measure was ULE (distance travelled by the eyelid margin between downgaze and upgaze). Normal and ptosis (MRD1 ≤ 2.5 mm or asymmetry ≥ 1 mm) subgroups were defined. Independent one-way ANOVA and independent samples t -tests were performed. This study was powered to detect a 1 mm difference in the primary outcome measure, assuming SD = 1 mm, with alpha = 0.05 and beta-error = 0.95. Results : Twenty-eight normal eyelids of 22 subjects and 28 ptotic eyes of 18 subjects were included. Stenting significantly ( p < 0.01) increased ULE in the overall sample (+0.9 mm) and in controls (+1.2 mm), but not ( p > 0.05) in ptotic eyelids (+0.5 mm). Post hoc analysis revealed a beta-error of 0.08 in the latter. Conclusion : ULE was significantly higher with brow stenting in normal eyelids (approximately +1.2 mm) but not in ptotic eyelids, possibly due to increased levator tone secondary to increased effort in the coupled frontalis.
- Is Part Of:
- Orbit. Volume 38:Number 5(2019)
- Journal:
- Orbit
- Issue:
- Volume 38:Number 5(2019)
- Issue Display:
- Volume 38, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 38
- Issue:
- 5
- Issue Sort Value:
- 2019-0038-0005-0000
- Page Start:
- 353
- Page End:
- 356
- Publication Date:
- 2019-09-03
- Subjects:
- Levator palpebrae superioris -- ptosis -- levator function -- preoperative assessment
Eye-sockets -- Surgery -- Periodicals
Eye-sockets -- Diseases -- Periodicals
Orbit -- surgery -- Periodicals
Orbital Diseases -- Periodicals
617.7 - Journal URLs:
- http://informahealthcare.com/loi/orb ↗
http://informahealthcare.com ↗
http://www.tandf.co.uk/journals/titles/01676830.asp ↗ - DOI:
- 10.1080/01676830.2018.1537289 ↗
- Languages:
- English
- ISSNs:
- 0167-6830
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6277.869600
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11685.xml