Comparison of supplemental oxygen delivery by continuous versus demand based flow systems in hypoxemic COPD patients – A randomized, single-blinded cross-over study. (September 2019)
- Record Type:
- Journal Article
- Title:
- Comparison of supplemental oxygen delivery by continuous versus demand based flow systems in hypoxemic COPD patients – A randomized, single-blinded cross-over study. (September 2019)
- Main Title:
- Comparison of supplemental oxygen delivery by continuous versus demand based flow systems in hypoxemic COPD patients – A randomized, single-blinded cross-over study
- Authors:
- Gloeckl, Rainer
Jarosch, Inga
Schneeberger, Tessa
Fiedler, Claudia
Lausen, Melody
Weingaertner, Julian
Hitzl, Wolfgang
Kenn, Klaus
Koczulla, Andreas Rembert - Abstract:
- Abstract: Background: Supplemental oxygen is a recommended therapy option in stable hypoxemic COPD patients. Often, supplemental oxygen is provided by continuous flow (CF). However, demand oxygen delivery systems (DODS) that provide an oxygen bolus only during inspiration have gained increasing use as they prolong oxygen cylinder life (beside battery life). However, there is a lack of evidence if different DODS and CF devices are equivalent. Methods: Seventy hypoxemic COPD patients (FEV1 32 ± 9% predicted, PaO2 56±7 mmHg) on long-term oxygen therapy were included in this prospective single-blinded, randomized cross-over trial. Following an initial incremental shuttle walk test, patients performed 3 endurance shuttle walk tests (ESWT) at 85% of their maximum walking speed in random order with: (A) CF (ESWT-CF), (B) a DODS based on liquid oxygen (ESWT-DL) and (C) an DODS oxygen concentrator (ESWT-DC). The primary outcome was oxygen saturation (SpO2 ) at ESWT isotime. Secondary outcomes were total ESWT duration, heart rate (HR) and breathing frequency (BF) at isotime and dyspnea at end-exercise. Results: SpO2 at ESWT isotime was not clinically different between devices: 90 ± 4% (CF), 89 ± 5% (DL) and 90 ± 5% (DC). However, 20% of the patients showed a ≥4% lower oxygen desaturation while using a DODS device. Secondary outcomes were similar under the three conditions. Conclusion: Oxygen supplementation via DODS (based on liquid oxygen or as a concentrator) yielded comparableAbstract: Background: Supplemental oxygen is a recommended therapy option in stable hypoxemic COPD patients. Often, supplemental oxygen is provided by continuous flow (CF). However, demand oxygen delivery systems (DODS) that provide an oxygen bolus only during inspiration have gained increasing use as they prolong oxygen cylinder life (beside battery life). However, there is a lack of evidence if different DODS and CF devices are equivalent. Methods: Seventy hypoxemic COPD patients (FEV1 32 ± 9% predicted, PaO2 56±7 mmHg) on long-term oxygen therapy were included in this prospective single-blinded, randomized cross-over trial. Following an initial incremental shuttle walk test, patients performed 3 endurance shuttle walk tests (ESWT) at 85% of their maximum walking speed in random order with: (A) CF (ESWT-CF), (B) a DODS based on liquid oxygen (ESWT-DL) and (C) an DODS oxygen concentrator (ESWT-DC). The primary outcome was oxygen saturation (SpO2 ) at ESWT isotime. Secondary outcomes were total ESWT duration, heart rate (HR) and breathing frequency (BF) at isotime and dyspnea at end-exercise. Results: SpO2 at ESWT isotime was not clinically different between devices: 90 ± 4% (CF), 89 ± 5% (DL) and 90 ± 5% (DC). However, 20% of the patients showed a ≥4% lower oxygen desaturation while using a DODS device. Secondary outcomes were similar under the three conditions. Conclusion: Oxygen supplementation via DODS (based on liquid oxygen or as a concentrator) yielded comparable physiological effects during standardized walking in stable hypoxemic COPD patients like CF. However, 20% of patients showed a clinically relevant lower oxygen saturation while using a DODS device. Therefore, we suggest individual testing of oxygen saturation of DODS suitability. Highlights: A large variety of oxygen delivery systems with different technologies is available Mean oxygen saturation during walking was comparable between different devices 20% of patients had a lower oxygen saturation while using a demand system Individual device testing on oxygenation in oxygen dependent patients is suggested … (more)
- Is Part Of:
- Respiratory medicine. Volume 156(2019)
- Journal:
- Respiratory medicine
- Issue:
- Volume 156(2019)
- Issue Display:
- Volume 156, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 156
- Issue:
- 2019
- Issue Sort Value:
- 2019-0156-2019-0000
- Page Start:
- 26
- Page End:
- 32
- Publication Date:
- 2019-09
- Subjects:
- Long-term oxygen therapy -- Exercise -- Endurance shuttle walk test -- Oxygen concentrator -- Liquid oxygen -- Pulmonary rehabilitation
Chest -- Diseases -- Periodicals
Chest -- Diseases -- Great Britain -- Periodicals
Respiratory organs -- Diseases -- Periodicals
Respiratory Tract Diseases -- Periodicals
Appareil respiratoire -- Maladies -- Périodiques
Thorax -- Maladies -- Périodiques
Appareil respiratoire -- Maladies -- Traitement -- Périodiques
Electronic journals
616.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09546111 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/09546111 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/09546111 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.rmed.2019.08.001 ↗
- Languages:
- English
- ISSNs:
- 0954-6111
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7777.661900
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11678.xml