Quantitative micro‐X‐ray fluorescence scanning spectroscopy of wet sediment based on the X‐ray absorption and emission theories: Its application to freshwater lake sedimentary sequences. Issue 6 (29th July 2019)
- Record Type:
- Journal Article
- Title:
- Quantitative micro‐X‐ray fluorescence scanning spectroscopy of wet sediment based on the X‐ray absorption and emission theories: Its application to freshwater lake sedimentary sequences. Issue 6 (29th July 2019)
- Main Title:
- Quantitative micro‐X‐ray fluorescence scanning spectroscopy of wet sediment based on the X‐ray absorption and emission theories: Its application to freshwater lake sedimentary sequences
- Authors:
- Katsuta, Nagayoshi
Takano, Masao
Sano, Naomi
Tani, Yukinori
Ochiai, Shinya
Naito, Sayuri
Murakami, Takuma
Niwa, Masakazu
Kawakami, Shin‐ichi - Abstract:
- Abstract: Micro‐X‐ray fluorescence scanning spectroscopy of marine and lake sedimentary sequences can provide detailed palaeoenvironmental records through element intensity proxy data. However, problems with the effects of interstitial pore water on the micro‐X‐ray fluorescence intensities have been pointed out. This is because the X‐ray fluorescence intensities are measured directly at the surfaces of split wet sediment core samples. This study developed a new method for correcting X‐ray fluorescence data to compensate for the effects of pore water using a scanning X‐ray analytical microscope. This involved simultaneous use of micro‐X‐ray fluorescence scanning spectroscopy and an X‐ray transmission detector. To evaluate the interstitial pore water content from the X‐ray transmission intensities, a fine‐grained sediment core retrieved from Lake Baikal (VER99‐G12) was used to prepare resin‐embedded samples with smooth surfaces and uniform thickness. Simple linear regression between the linear absorption coefficients of the samples and their porosity, based on the Lambert–Beer law, enabled calculation of the interstitial pore spaces and their resin content with high reproducibility. The X‐ray fluorescence intensities of resin‐embedded samples were reduced compared with those of dry sediment samples because of: (i) the X‐ray fluorescence absorption of resin within sediment; and (ii) the sediment dilution effects by resin. An improved micro‐X‐ray fluorescence correctionAbstract: Micro‐X‐ray fluorescence scanning spectroscopy of marine and lake sedimentary sequences can provide detailed palaeoenvironmental records through element intensity proxy data. However, problems with the effects of interstitial pore water on the micro‐X‐ray fluorescence intensities have been pointed out. This is because the X‐ray fluorescence intensities are measured directly at the surfaces of split wet sediment core samples. This study developed a new method for correcting X‐ray fluorescence data to compensate for the effects of pore water using a scanning X‐ray analytical microscope. This involved simultaneous use of micro‐X‐ray fluorescence scanning spectroscopy and an X‐ray transmission detector. To evaluate the interstitial pore water content from the X‐ray transmission intensities, a fine‐grained sediment core retrieved from Lake Baikal (VER99‐G12) was used to prepare resin‐embedded samples with smooth surfaces and uniform thickness. Simple linear regression between the linear absorption coefficients of the samples and their porosity, based on the Lambert–Beer law, enabled calculation of the interstitial pore spaces and their resin content with high reproducibility. The X‐ray fluorescence intensities of resin‐embedded samples were reduced compared with those of dry sediment samples because of: (i) the X‐ray fluorescence absorption of resin within sediment; and (ii) the sediment dilution effects by resin. An improved micro‐X‐ray fluorescence correction equation based on X‐ray fluorescence emission theory considers the instrument's sensitivity to each element, which provides a reasonable explanation of these two effects. The resin‐corrected X‐ray fluorescence intensity was then successfully converted to elemental concentrations using simple linear regression between the data from micro‐X‐ray fluorescence scanning spectroscopy and from the conventional analyzer. In particular, the calculated concentration of SiO2 over the depth of the core, reflecting diatom/biogenic silica concentration, was significantly changed by the calibrations, from a progressively decreasing trend to an increasing trend towards the top of the core. … (more)
- Is Part Of:
- Sedimentology. Volume 66:Issue 6(2019)
- Journal:
- Sedimentology
- Issue:
- Volume 66:Issue 6(2019)
- Issue Display:
- Volume 66, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 66
- Issue:
- 6
- Issue Sort Value:
- 2019-0066-0006-0000
- Page Start:
- 2490
- Page End:
- 2510
- Publication Date:
- 2019-07-29
- Subjects:
- Absorption -- correction methodologies -- dilution -- freshwater lake sediment -- interstitial pore water -- μ‐XRF scanning spectroscopy
Sedimentology -- Periodicals
552.5 - Journal URLs:
- http://www.blackwell-synergy.com ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-3091 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/sed.12603 ↗
- Languages:
- English
- ISSNs:
- 0037-0746
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8217.400000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11674.xml