Stereoelectroencephalography electrode placement: Detection of blood vessel conflicts. (22nd July 2019)
- Record Type:
- Journal Article
- Title:
- Stereoelectroencephalography electrode placement: Detection of blood vessel conflicts. (22nd July 2019)
- Main Title:
- Stereoelectroencephalography electrode placement: Detection of blood vessel conflicts
- Authors:
- Li, Kuo
Vakharia, Vejay N.
Sparks, Rachel
Rodionov, Roman
Vos, Sjoerd B.
McEvoy, Andrew W.
Miserocchi, Anna
Wang, Maode
Ourselin, Sebastien
Duncan, John S. - Abstract:
- Abstract: Objective: Various forms of vascular imaging are performed to identify vessels that should be avoided during stereoelectroencephalography (SEEG) planning. Digital subtraction angiography (DSA) is the gold standard for intracranial vascular imaging. DSA is an invasive investigation, and a balance is necessary to identify all clinically relevant vessels and not to visualize irrelevant vessels that may unnecessarily restrict electrode placement. We sought to estimate the size of vessels that are clinically significant for SEEG planning. Methods: Thirty‐three consecutive patients who underwent 354 SEEG electrode implantations planned with computer‐assisted planning and DSA segmentation between 2016 and 2018 were identified from a prospectively maintained database. Intracranial positions of electrodes were segmented from postimplantation computed tomography scans. Each electrode was manually reviewed using "probe‐eye view" with the raw preoperative DSA images for vascular conflicts. The diameter of vessels and the location of conflicts were noted. Vessel conflicts identified on raw DSA images were cross‐referenced against other modalities to determine whether the conflict could have been detected. Results: One hundred sixty‐six vessel conflicts were identified between electrodes and DSA‐identified vessels, with 0‐3 conflicts per electrode and a median of four conflicts per patient. The median diameter of conflicting vessels was 1.3 mm (interquartile range [IQR] =Abstract: Objective: Various forms of vascular imaging are performed to identify vessels that should be avoided during stereoelectroencephalography (SEEG) planning. Digital subtraction angiography (DSA) is the gold standard for intracranial vascular imaging. DSA is an invasive investigation, and a balance is necessary to identify all clinically relevant vessels and not to visualize irrelevant vessels that may unnecessarily restrict electrode placement. We sought to estimate the size of vessels that are clinically significant for SEEG planning. Methods: Thirty‐three consecutive patients who underwent 354 SEEG electrode implantations planned with computer‐assisted planning and DSA segmentation between 2016 and 2018 were identified from a prospectively maintained database. Intracranial positions of electrodes were segmented from postimplantation computed tomography scans. Each electrode was manually reviewed using "probe‐eye view" with the raw preoperative DSA images for vascular conflicts. The diameter of vessels and the location of conflicts were noted. Vessel conflicts identified on raw DSA images were cross‐referenced against other modalities to determine whether the conflict could have been detected. Results: One hundred sixty‐six vessel conflicts were identified between electrodes and DSA‐identified vessels, with 0‐3 conflicts per electrode and a median of four conflicts per patient. The median diameter of conflicting vessels was 1.3 mm (interquartile range [IQR] = 1.0‐1.5 mm). The median depth of conflict was 31.0 mm (IQR = 14.3‐45.0 mm) from the cortical surface. The addition of sulcal models to DSA, magnetic resonance venography (MRV), and T1 + gadolinium images, as an exclusion zone during computer‐assisted planning, would have prevented the majority of vessel conflicts. We were unable to determine whether vessels were displaced or transected by the electrodes. Significance: Vascular segmentation from DSA images was significantly more sensitive than T1 + gadolinium or MRV images. Electrode conflicts with vessels 1‐1.5 mm in size did not result in a radiologically detectable or clinically significant hemorrhage and could potentially be excluded from consideration during SEEG planning. … (more)
- Is Part Of:
- Epilepsia. Volume 60:issue 9(2019)
- Journal:
- Epilepsia
- Issue:
- Volume 60:issue 9(2019)
- Issue Display:
- Volume 60, Issue 9 (2019)
- Year:
- 2019
- Volume:
- 60
- Issue:
- 9
- Issue Sort Value:
- 2019-0060-0009-0000
- Page Start:
- 1942
- Page End:
- 1948
- Publication Date:
- 2019-07-22
- Subjects:
- computer‐assisted planning -- segmentation -- stereoelectroencephalography -- vascular imaging
Epilepsy -- Periodicals
616.853 - Journal URLs:
- http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=epi ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/epi.16294 ↗
- Languages:
- English
- ISSNs:
- 0013-9580
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3793.700000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11656.xml