Acoustophoretic rapid media exchange and continuous-flow electrotransfection of primary human T cells for applications in automated cellular therapy manufacturing. Issue 18 (14th August 2019)
- Record Type:
- Journal Article
- Title:
- Acoustophoretic rapid media exchange and continuous-flow electrotransfection of primary human T cells for applications in automated cellular therapy manufacturing. Issue 18 (14th August 2019)
- Main Title:
- Acoustophoretic rapid media exchange and continuous-flow electrotransfection of primary human T cells for applications in automated cellular therapy manufacturing
- Authors:
- Hsi, Peter
Christianson, Rebecca J.
Dubay, Ryan A.
Lissandrello, Charles A.
Fiering, Jason
Balestrini, Jenna L.
Tandon, Vishal - Abstract:
- Abstract : Our novel device acoustophoretically transfers cells from culture media to electroporation media and then electroporates them using integrated electrodes. Abstract : Autologous cellular therapies based on modifying T cells to express chimeric antigen receptor genes have been highly successful in treating hematological cancers. Deployment of these therapies is limited by the complexity and costs associated with their manufacturing. Transitioning these processes from virus-based methods for gene delivery to a non-viral method, such as electroporation, has the potential to greatly reduce cost and manufacturing time while increasing safety and efficacy. Major challenges with electroporation are the negative impacts on cell health associated with exposure to high-magnitude electric fields, and that most commercial bulk electroporators are low-precision instruments designed for manually-operated, lower-throughput batch processing of cells. Negative effects on cell health can be mitigated by use of specialized electroporation medias, but this adds processing steps, and long-term exposure to these medias can reduce transfection efficiency and post-transfection viability. To enable automated, clinical-scale production of cellular therapies using electrotransfection in specialized medias, we developed a high-precision microfluidic platform that automatically and continuously transfers cells from culture media into electroporation media using acoustophoresis, and thenAbstract : Our novel device acoustophoretically transfers cells from culture media to electroporation media and then electroporates them using integrated electrodes. Abstract : Autologous cellular therapies based on modifying T cells to express chimeric antigen receptor genes have been highly successful in treating hematological cancers. Deployment of these therapies is limited by the complexity and costs associated with their manufacturing. Transitioning these processes from virus-based methods for gene delivery to a non-viral method, such as electroporation, has the potential to greatly reduce cost and manufacturing time while increasing safety and efficacy. Major challenges with electroporation are the negative impacts on cell health associated with exposure to high-magnitude electric fields, and that most commercial bulk electroporators are low-precision instruments designed for manually-operated, lower-throughput batch processing of cells. Negative effects on cell health can be mitigated by use of specialized electroporation medias, but this adds processing steps, and long-term exposure to these medias can reduce transfection efficiency and post-transfection viability. To enable automated, clinical-scale production of cellular therapies using electrotransfection in specialized medias, we developed a high-precision microfluidic platform that automatically and continuously transfers cells from culture media into electroporation media using acoustophoresis, and then immediately applies electric fields from integrated electrodes. This limits cell residence time in electroporation media to seconds, and enables high transfection efficiency with minimum impact on cell viability. We tested our system by transferring primary human T cells from a standard cell media to electroporation media, and then transfecting them with mRNA encoding an mCherry fluorescent protein. We achieved a media exchange efficiency of 86% and transfection efficiency of up to 60%, with less than a 5% reduction in viability. … (more)
- Is Part Of:
- Lab on a chip. Volume 19:Issue 18(2019)
- Journal:
- Lab on a chip
- Issue:
- Volume 19:Issue 18(2019)
- Issue Display:
- Volume 19, Issue 18 (2019)
- Year:
- 2019
- Volume:
- 19
- Issue:
- 18
- Issue Sort Value:
- 2019-0019-0018-0000
- Page Start:
- 2978
- Page End:
- 2992
- Publication Date:
- 2019-08-14
- Subjects:
- Miniature electronic equipment -- Periodicals
Combinatorial chemistry -- Periodicals
Biotechnology -- Periodicals
543.0813 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/lc#!recentarticles&adv ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c9lc00458k ↗
- Languages:
- English
- ISSNs:
- 1473-0197
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5137.730000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File: