The feasibility of low-concentration contrast and low tube voltage in computed tomography perfusion imaging: an animal study. Issue 1 (10th January 2018)
- Record Type:
- Journal Article
- Title:
- The feasibility of low-concentration contrast and low tube voltage in computed tomography perfusion imaging: an animal study. Issue 1 (10th January 2018)
- Main Title:
- The feasibility of low-concentration contrast and low tube voltage in computed tomography perfusion imaging: an animal study
- Authors:
- Pan, Yuning
Song, Aiqin
Bu, Shizhong
Chen, Zhaoqian
Huang, Qiuli
Li, Aijing - Abstract:
- Abstract : Aim: To investigate the feasibility of low-concentration contrast (270 mg/ml) together with low tube voltage (80 kV) and adaptive iterative dose reduction (AIDR)-3D reconstruction in liver computed tomography (CT) perfusion imaging. Method: A total of 15 healthy New Zealand rabbits received two CT scans each. The first scan (control) was acquired at 100 kV and 100 mA with iopromide (370 mg/ml), while the second scan (experimental) was acquired at 80 kV and 100 mA with iodixanol (270 mg/ml) 24 h after the first scan. The obtained images were reconstructed with filtered back projection (FBP) and AIDR-3D in the control and experimental groups respectively. The perfusion parameters (hepatic artery perfusion [HAP], portal vein perfusion [PVP], hepatic perfusion index [HPI], and total liver perfusion [TLP]) and image quality (image quality score, average CT value of abdomen aorta, signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR], and figure of merit [FOM]) were compared using a paired t -test or Mann–Whitney U test between the two groups, when appropriate. The effective radiation dose and iodine intake were also recorded and compared. Results: With the exception of the FOM criteria, the image quality and perfusion parameters were not significantly different between the two groups. The effective radiation dose and iodine intake were 38.79% and 27.03% lower respectively, in the experimental group. Conclusion: Low-concentration contrast (iodixanol, 270 mg/ml)Abstract : Aim: To investigate the feasibility of low-concentration contrast (270 mg/ml) together with low tube voltage (80 kV) and adaptive iterative dose reduction (AIDR)-3D reconstruction in liver computed tomography (CT) perfusion imaging. Method: A total of 15 healthy New Zealand rabbits received two CT scans each. The first scan (control) was acquired at 100 kV and 100 mA with iopromide (370 mg/ml), while the second scan (experimental) was acquired at 80 kV and 100 mA with iodixanol (270 mg/ml) 24 h after the first scan. The obtained images were reconstructed with filtered back projection (FBP) and AIDR-3D in the control and experimental groups respectively. The perfusion parameters (hepatic artery perfusion [HAP], portal vein perfusion [PVP], hepatic perfusion index [HPI], and total liver perfusion [TLP]) and image quality (image quality score, average CT value of abdomen aorta, signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR], and figure of merit [FOM]) were compared using a paired t -test or Mann–Whitney U test between the two groups, when appropriate. The effective radiation dose and iodine intake were also recorded and compared. Results: With the exception of the FOM criteria, the image quality and perfusion parameters were not significantly different between the two groups. The effective radiation dose and iodine intake were 38.79% and 27.03% lower respectively, in the experimental group. Conclusion: Low-concentration contrast (iodixanol, 270 mg/ml) together with low tube voltage (80 kV) and AIDR-3D reconstruction help to reduce radiation dose and iodine intake without compromising perfusion parameters and image quality in liver CT perfusion imaging. … (more)
- Is Part Of:
- Bioscience reports. Volume 38:Issue 1(2018)
- Journal:
- Bioscience reports
- Issue:
- Volume 38:Issue 1(2018)
- Issue Display:
- Volume 38, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 38
- Issue:
- 1
- Issue Sort Value:
- 2018-0038-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-01-10
- Subjects:
- AIDR-3D reconstruction -- computed tomography -- liver -- low-concentration contrast -- low tube voltage -- perfusion imaging
Molecular biology -- Periodicals
Cytology -- Periodicals
572.8 - Journal URLs:
- http://www.bioscirep.org/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1042/BSR20170977 ↗
- Languages:
- English
- ISSNs:
- 0144-8463
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2089.611600
British Library HMNTS - ELD Digital store - Ingest File:
- 11647.xml