Microdosimetry at the CATANA 62 MeV proton beam with a sealed miniaturized TEPC. (August 2019)
- Record Type:
- Journal Article
- Title:
- Microdosimetry at the CATANA 62 MeV proton beam with a sealed miniaturized TEPC. (August 2019)
- Main Title:
- Microdosimetry at the CATANA 62 MeV proton beam with a sealed miniaturized TEPC
- Authors:
- Conte, V.
Bianchi, A.
Selva, A.
Petringa, G.
Cirrone, G.A.P.
Parisi, A.
Vanhavere, F.
Colautti, P. - Abstract:
- Highlights: Miniature Tissue Equivalent Proportional Counters can work without gas-flow. The new sealed mini-TEPC gives reproducible results over a period of 4 months. The new mini-TEPC can be used as a precise LET-monitor in proton therapy. The new mini-TEPC measurements result in a reasonable RBE-assessment. The mini-TEPC can be used for a comparative study of different radiotherapy centres. Abstract: A new mini-TEPC with cylindrical sensitive volume of 0.9 mm in diameter and height, and with external diameter of 2.7 mm, has been developed to work without gas flow. With such a mini counter we have measured the physical quality of the 62 MeV therapeutic proton beam of CATANA (Catania, Italy). Measurements were performed at six precise positions along the Spread-Out Bragg Peak (SOBP): 1.4, 19.4, 24.6, 29.0, 29.7 and 30.8 mm, corresponding to positions of clinical relevance (entrance, proximal, central, and distal-edge of the SOBP) or of high lineal energy transfer (LET) increment (distal-dose drop off). Without refilling the microdosimeter with new gas, the measurements were repeated at the same positions 4 months later, in order to study the stability of the response in sealed-mode operation. From the microdosimetric spectra the frequency-mean lineal energy y - F and the dose-mean lineal energy y - D were derived and compared with average LET values calculated by means of Geant4 simulations. The comparison points out, in particular, a good agreement between microdosimetricHighlights: Miniature Tissue Equivalent Proportional Counters can work without gas-flow. The new sealed mini-TEPC gives reproducible results over a period of 4 months. The new mini-TEPC can be used as a precise LET-monitor in proton therapy. The new mini-TEPC measurements result in a reasonable RBE-assessment. The mini-TEPC can be used for a comparative study of different radiotherapy centres. Abstract: A new mini-TEPC with cylindrical sensitive volume of 0.9 mm in diameter and height, and with external diameter of 2.7 mm, has been developed to work without gas flow. With such a mini counter we have measured the physical quality of the 62 MeV therapeutic proton beam of CATANA (Catania, Italy). Measurements were performed at six precise positions along the Spread-Out Bragg Peak (SOBP): 1.4, 19.4, 24.6, 29.0, 29.7 and 30.8 mm, corresponding to positions of clinical relevance (entrance, proximal, central, and distal-edge of the SOBP) or of high lineal energy transfer (LET) increment (distal-dose drop off). Without refilling the microdosimeter with new gas, the measurements were repeated at the same positions 4 months later, in order to study the stability of the response in sealed-mode operation. From the microdosimetric spectra the frequency-mean lineal energy y - F and the dose-mean lineal energy y - D were derived and compared with average LET values calculated by means of Geant4 simulations. The comparison points out, in particular, a good agreement between microdosimetric y - D and the total dose-average L E T ¯ d, which is the average LET of the mixed radiation field, including the contribution by nuclear reactions. … (more)
- Is Part Of:
- Physica medica. Volume 64(2019)
- Journal:
- Physica medica
- Issue:
- Volume 64(2019)
- Issue Display:
- Volume 64, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 64
- Issue:
- 2019
- Issue Sort Value:
- 2019-0064-2019-0000
- Page Start:
- 114
- Page End:
- 122
- Publication Date:
- 2019-08
- Subjects:
- TEPC -- Microdosimetry -- Proton therapy -- Proton RBE
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2019.06.011 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: