Undetected non-conformities in material processing led to a service failure in a casing hanger during pre-fracture operation. (October 2019)
- Record Type:
- Journal Article
- Title:
- Undetected non-conformities in material processing led to a service failure in a casing hanger during pre-fracture operation. (October 2019)
- Main Title:
- Undetected non-conformities in material processing led to a service failure in a casing hanger during pre-fracture operation
- Authors:
- Cirimello, Pablo
Otegui, Jose Luis
Aguirre, Alberto
Carfi, Guillermo - Abstract:
- Abstract: The failure of a 5″ casing hanger at an oil well led to costly workover operations and lost production. The brittle failure was due to the instantaneous propagation of a circumferential fracture, initiated at a geometrical stress raiser. Combined operation stresses from internal pressure, casing weight and tightening torque were close to the yield strength of the material. If the material had sufficient ductility, plastic deformation would have led to stress relaxation and redistribution. But a SAE/AISI 4140 steel with a low forging ratio, plus a poor heat treatment and incomplete quenching, led to a banded microstructure with both low strength and toughness, and a consequent limited capacity for plastic deformation. Geometric discontinuities due to elongated inclusions and other microestructural defects justify crack propagation at the reported service loads. Quality assurance failed to prevent unacceptable pieces. Some recommendations are provided to reduce the likelihood of recurrence in new hangers: an appropriate microstructure must be assured, controlling the forging stages and heat treatment parameters. The representativeness of test coupons used for quality control must be ensured. Re -evaluating the geometry of the casing hanger and switching to a steel with higher hardenability would lead to more defect - tolerant components. Highlights: The failure of a 5" casing hanger at an oil well led to costly workover operations and lost production. The brittleAbstract: The failure of a 5″ casing hanger at an oil well led to costly workover operations and lost production. The brittle failure was due to the instantaneous propagation of a circumferential fracture, initiated at a geometrical stress raiser. Combined operation stresses from internal pressure, casing weight and tightening torque were close to the yield strength of the material. If the material had sufficient ductility, plastic deformation would have led to stress relaxation and redistribution. But a SAE/AISI 4140 steel with a low forging ratio, plus a poor heat treatment and incomplete quenching, led to a banded microstructure with both low strength and toughness, and a consequent limited capacity for plastic deformation. Geometric discontinuities due to elongated inclusions and other microestructural defects justify crack propagation at the reported service loads. Quality assurance failed to prevent unacceptable pieces. Some recommendations are provided to reduce the likelihood of recurrence in new hangers: an appropriate microstructure must be assured, controlling the forging stages and heat treatment parameters. The representativeness of test coupons used for quality control must be ensured. Re -evaluating the geometry of the casing hanger and switching to a steel with higher hardenability would lead to more defect - tolerant components. Highlights: The failure of a 5" casing hanger at an oil well led to costly workover operations and lost production. The brittle failure was due to the instantaneous propagation of a circumferential fracture, initiated at a geometrical stress raiser. Geometric discontinuities due to elongated inclusions and other microstructural defects justify crack propagation at the reported service loads. Quality assurance failed to prevent unacceptable pieces. … (more)
- Is Part Of:
- Engineering failure analysis. Volume 104(2019)
- Journal:
- Engineering failure analysis
- Issue:
- Volume 104(2019)
- Issue Display:
- Volume 104, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 104
- Issue:
- 2019
- Issue Sort Value:
- 2019-0104-2019-0000
- Page Start:
- 203
- Page End:
- 215
- Publication Date:
- 2019-10
- Subjects:
- Casing hanger -- Toughness -- Elongated inclusions -- Non-conformities
System failures (Engineering) -- Periodicals
Fracture mechanics -- Periodicals
Reliability (Engineering) -- Periodicals
Pannes -- Périodiques
Rupture, Mécanique de la -- Périodiques
Fiabilité -- Périodiques
Fracture mechanics
Reliability (Engineering)
System failures (Engineering)
Periodicals
Electronic journals
620.112 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13506307 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.engfailanal.2019.05.026 ↗
- Languages:
- English
- ISSNs:
- 1350-6307
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3760.991000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11635.xml