Evaluation of the intra- and inter-method agreement of brain MRI segmentation software packages: A comparison between SPM12 and FreeSurfer v6.0. (August 2019)
- Record Type:
- Journal Article
- Title:
- Evaluation of the intra- and inter-method agreement of brain MRI segmentation software packages: A comparison between SPM12 and FreeSurfer v6.0. (August 2019)
- Main Title:
- Evaluation of the intra- and inter-method agreement of brain MRI segmentation software packages: A comparison between SPM12 and FreeSurfer v6.0
- Authors:
- Palumbo, L.
Bosco, P.
Fantacci, M.E.
Ferrari, E.
Oliva, P.
Spera, G.
Retico, A. - Abstract:
- Highlights: Different segmentation pipelines may provide inconsistent quantification of brain structures. The intra- and inter-method agreement between two popular segmentation software packages SPM12 and FreeSurfer v6.0. SPM provides more consistent results both in the intra- and the inter-method agreement evaluation. There are consistent biases in the estimates of gray matter and white matter between SPM and FreeSurfer. To cross-validate the findings of each study against different segmentation methods before interpreting of the results. Abstract: Purpose: The lack of inter-method agreement can produce inconsistent results in neuroimaging studies. We evaluated the intra-method repeatability and the inter-method reproducibility of two widely-used automatic segmentation methods for brain MRI: the FreeSurfer (FS) and the Statistical Parametric Mapping (SPM) software packages. Methods: We segmented the gray matter (GM), the white matter (WM) and subcortical structures in test-retest MRI data of healthy volunteers from Kirby-21 and OASIS datasets. We used Pearson's correlation (r), Bland-Altman plot and Dice index to study intra-method repeatability and inter-method reproducibility. In order to test whether different processing methods affect the results of a neuroimaging-based group study, we carried out a statistical comparison between male and female volume measures. Results: A high correlation was found between test-retest volume measures for both SPM (r in the 0.98–0.99Highlights: Different segmentation pipelines may provide inconsistent quantification of brain structures. The intra- and inter-method agreement between two popular segmentation software packages SPM12 and FreeSurfer v6.0. SPM provides more consistent results both in the intra- and the inter-method agreement evaluation. There are consistent biases in the estimates of gray matter and white matter between SPM and FreeSurfer. To cross-validate the findings of each study against different segmentation methods before interpreting of the results. Abstract: Purpose: The lack of inter-method agreement can produce inconsistent results in neuroimaging studies. We evaluated the intra-method repeatability and the inter-method reproducibility of two widely-used automatic segmentation methods for brain MRI: the FreeSurfer (FS) and the Statistical Parametric Mapping (SPM) software packages. Methods: We segmented the gray matter (GM), the white matter (WM) and subcortical structures in test-retest MRI data of healthy volunteers from Kirby-21 and OASIS datasets. We used Pearson's correlation (r), Bland-Altman plot and Dice index to study intra-method repeatability and inter-method reproducibility. In order to test whether different processing methods affect the results of a neuroimaging-based group study, we carried out a statistical comparison between male and female volume measures. Results: A high correlation was found between test-retest volume measures for both SPM (r in the 0.98–0.99 range) and FS (r in the 0.95–0.99 range). A non-null bias between test-retest FS volumes was detected for GM and WM in the OASIS dataset. The inter-method reproducibility analysis measured volume correlation values in the 0.72–0.98 range and the overlap between the segmented structures assessed by the Dice index was in the 0.76–0.83 range. SPM systematically provided significantly greater GM volumes and lower WM and subcortical volumes with respect to FS. In the male vs. female brain volume comparisons, inconsistencies arose for the OASIS dataset, where the gender-related differences appear subtler with respect to the Kirby dataset. Conclusions: The inter-method reproducibility should be evaluated before interpreting the results of neuroimaging studies. … (more)
- Is Part Of:
- Physica medica. Volume 64(2019)
- Journal:
- Physica medica
- Issue:
- Volume 64(2019)
- Issue Display:
- Volume 64, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 64
- Issue:
- 2019
- Issue Sort Value:
- 2019-0064-2019-0000
- Page Start:
- 261
- Page End:
- 272
- Publication Date:
- 2019-08
- Subjects:
- Brain MRI -- Segmentation -- Repeatability -- Reproducibility
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2019.07.016 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11638.xml