Comparison of standard vs modified "figure‐of‐eight" suture to achieve femoral venous hemostasis after cryoballoon based atrial fibrillation ablation. Issue 9 (5th August 2019)
- Record Type:
- Journal Article
- Title:
- Comparison of standard vs modified "figure‐of‐eight" suture to achieve femoral venous hemostasis after cryoballoon based atrial fibrillation ablation. Issue 9 (5th August 2019)
- Main Title:
- Comparison of standard vs modified "figure‐of‐eight" suture to achieve femoral venous hemostasis after cryoballoon based atrial fibrillation ablation
- Authors:
- Yorgun, Hikmet
Canpolat, Uğur
Ates, Ahmet Hakan
Oksul, Metin
Sener, Yusuf Ziya
Akkaya, Fatih
Aytemir, Kudret - Abstract:
- Abstract: Background: Immediate hemostasis following removal of sheaths is essential to prevent access site complications after atrial fibrillation (AF) ablation. Despite various precautions to achieve complete hemostasis in a safe and effective manner, no standard approach is present yet. Objective: We aimed to compare the efficacy and safety of standard vs modified figure‐of‐eight (sFoE vs mFoE) suture for immediate venous hemostasis after cryoballoon (CB) AF ablation. Methods: A total of 150 patients who underwent CB catheter ablation were sequentially allocated to either sFoE ( n = 75) or mFoE ( n = 75) suture to achieve immediate venous hemostasis at right femoral access site after 15 Fr sheath removal. A "three‐way stopcock" was used in the mFoE group rather than tying the knot as in a sFoE group. Demographics, clinical and procedural data, and access site complications were recorded. Results: Immediate haemostasis was achieved in all patients ( n = 75) with mFoE suture as compared to 90.7% ( n = 68) of sFoE suture group ( P < .001). Light manual pressure of ≤1 min was required in five patients (6.7%) due to looseness and conventional manual compression because of the snapped silk suture during knotting was required in two patients (2.6%) in the sFoE group. Time to hemostasis was shorter in the mFoE group ( P < .001), but time to ambulation and time to discharge were similar in both groups ( P > .05). Although no minor or major access site complication has occurred inAbstract: Background: Immediate hemostasis following removal of sheaths is essential to prevent access site complications after atrial fibrillation (AF) ablation. Despite various precautions to achieve complete hemostasis in a safe and effective manner, no standard approach is present yet. Objective: We aimed to compare the efficacy and safety of standard vs modified figure‐of‐eight (sFoE vs mFoE) suture for immediate venous hemostasis after cryoballoon (CB) AF ablation. Methods: A total of 150 patients who underwent CB catheter ablation were sequentially allocated to either sFoE ( n = 75) or mFoE ( n = 75) suture to achieve immediate venous hemostasis at right femoral access site after 15 Fr sheath removal. A "three‐way stopcock" was used in the mFoE group rather than tying the knot as in a sFoE group. Demographics, clinical and procedural data, and access site complications were recorded. Results: Immediate haemostasis was achieved in all patients ( n = 75) with mFoE suture as compared to 90.7% ( n = 68) of sFoE suture group ( P < .001). Light manual pressure of ≤1 min was required in five patients (6.7%) due to looseness and conventional manual compression because of the snapped silk suture during knotting was required in two patients (2.6%) in the sFoE group. Time to hemostasis was shorter in the mFoE group ( P < .001), but time to ambulation and time to discharge were similar in both groups ( P > .05). Although no minor or major access site complication has occurred in the mFoE group, in‐hospital rebleeding ( n = 2, 2.7%) and early local access site infection ( n = 2, 2.7%) were observed in the sFoE group. Conclusion: The mFoE suture using three‐way stopcock is an available, effective, maybe safe, and time‐ and cost‐saving alternative technique to achieve immediate hemostasis after removal of 15 Fr right femoral venous sheath in patients undergoing cryoablation. … (more)
- Is Part Of:
- Pacing and clinical electrophysiology. Volume 42:Issue 9(2019)
- Journal:
- Pacing and clinical electrophysiology
- Issue:
- Volume 42:Issue 9(2019)
- Issue Display:
- Volume 42, Issue 9 (2019)
- Year:
- 2019
- Volume:
- 42
- Issue:
- 9
- Issue Sort Value:
- 2019-0042-0009-0000
- Page Start:
- 1175
- Page End:
- 1182
- Publication Date:
- 2019-08-05
- Subjects:
- atrial fibrillation ablation -- suture -- three‐way stopcock -- venous hemostasis
Cardiac pacing -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8159 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=pace ↗
http://www.futuraco.com/journalsf.htm ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0147-8389;screen=info;ECOIP ↗ - DOI:
- 10.1111/pace.13764 ↗
- Languages:
- English
- ISSNs:
- 0147-8389
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6328.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11637.xml