Scattering matrix imaging pulse design for real‐time respiration and cardiac motion monitoring. Issue 6 (17th July 2019)
- Record Type:
- Journal Article
- Title:
- Scattering matrix imaging pulse design for real‐time respiration and cardiac motion monitoring. Issue 6 (17th July 2019)
- Main Title:
- Scattering matrix imaging pulse design for real‐time respiration and cardiac motion monitoring
- Authors:
- Jaeschke, Sven H. F.
Robson, Matthew D.
Hess, Aaron T. - Abstract:
- Abstract : Purpose: The scattering matrix (S‐matrix) of a parallel transmit (pTx) coil is sensitive to physiological motion but requires additional monitoring RF pulses to be measured. In this work, we present and evaluate pTx RF pulse designs that simultaneously excite for imaging and measure the S‐matrix to generate real‐time motion signals without prolonging the image sequence. Theory and Methods: Three pTx waveforms for measuring the S‐matrix were identified and superimposed onto the imaging excitation RF pulses: (1) time division multiplexing, (2) frequency division multiplexing, and (3) code division multiplexing. These 3 methods were evaluated in healthy volunteers for scattering sensitivity and image artefacts. The S‐matrix and real‐time motion signals were calculated on the image calculation environment of the MR scanner. Prospective cardiac triggers were identified in early systole as a high rate of change of the cardiac motion signal. Monitoring accuracy was compared against electrocardiogram or the imaged diaphragm position. Results: All 3 monitoring approaches measure the S‐matrix during image excitation with quality correlated to input power. No image artefacts were observed for frequency multiplexing, and low energy artefacts were observed in the other methods. The accuracy of the achieved prospective cardiac gating was 15 ± 16 ms for breath hold and 24 ± 17 ms during free breathing. The diaphragm position prediction accuracy was 1.3 ± 0.9 mm. In allAbstract : Purpose: The scattering matrix (S‐matrix) of a parallel transmit (pTx) coil is sensitive to physiological motion but requires additional monitoring RF pulses to be measured. In this work, we present and evaluate pTx RF pulse designs that simultaneously excite for imaging and measure the S‐matrix to generate real‐time motion signals without prolonging the image sequence. Theory and Methods: Three pTx waveforms for measuring the S‐matrix were identified and superimposed onto the imaging excitation RF pulses: (1) time division multiplexing, (2) frequency division multiplexing, and (3) code division multiplexing. These 3 methods were evaluated in healthy volunteers for scattering sensitivity and image artefacts. The S‐matrix and real‐time motion signals were calculated on the image calculation environment of the MR scanner. Prospective cardiac triggers were identified in early systole as a high rate of change of the cardiac motion signal. Monitoring accuracy was compared against electrocardiogram or the imaged diaphragm position. Results: All 3 monitoring approaches measure the S‐matrix during image excitation with quality correlated to input power. No image artefacts were observed for frequency multiplexing, and low energy artefacts were observed in the other methods. The accuracy of the achieved prospective cardiac gating was 15 ± 16 ms for breath hold and 24 ± 17 ms during free breathing. The diaphragm position prediction accuracy was 1.3 ± 0.9 mm. In all volunteers, good quality cine images were acquired for breath hold scans and dual gated CINEs were demonstrated. Conclusion: The S‐matrix can be measured during image excitation to generate real‐time cardiac and respiratory motion signals for prospective gating. No artefacts are introduced when frequency division multiplexing is used. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 82:Issue 6(2019)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 82:Issue 6(2019)
- Issue Display:
- Volume 82, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 82
- Issue:
- 6
- Issue Sort Value:
- 2019-0082-0006-0000
- Page Start:
- 2169
- Page End:
- 2177
- Publication Date:
- 2019-07-17
- Subjects:
- cardiac self‐gating -- cardiovascular magnetic resonance -- dual gating -- parallel transmit -- respiratory motion -- ultra‐high field MRI
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27884 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11610.xml