Non-Poisson variations in photomultipliers and implications for luminescence dating. (15th December 2018)
- Record Type:
- Journal Article
- Title:
- Non-Poisson variations in photomultipliers and implications for luminescence dating. (15th December 2018)
- Main Title:
- Non-Poisson variations in photomultipliers and implications for luminescence dating
- Authors:
- Carter, J.
Cresswell, A.J.
Kinnaird, T.C.
Carmichael, L.A.
Murphy, S.
Sanderson, D.C.W. - Abstract:
- Abstract: Previous studies have suggested that excess variations from single-photon counting systems used in luminescence dating may result in underestimation of errors and profoundly influence age models. In this study ten different photon counting systems have been investigated to explore this effect with a greater number of photomultiplier types and instrumental architectures. It is shown that radiation induced phosphorescence from F1 feldspar produces a controllable low-level light source whose local variance approximates Poisson expectations. However excess variation in dark counts was observed to varying extents from all systems. The excess variance is slightly anti-correlated with the age of the system, with older devices conforming more closely to Poisson behaviour. This observation does not seem to fit the hypothesis that enhanced levels of helium diffused into older tubes increase non-Poisson components. It was noted that a significant part of the non-Poisson behaviour was associated with multi-event pulse streams within time series. Work was also undertaken to develop mitigation methods for data analysis and to examine the implications for dating uncertainties in a test case. A Poisson-filtering algorithm was developed to identify and remove improbable multi-event streams. Application to data from signal-limited single grains of sediments from a Neolithic chambered tomb in Corsica has shown that, for this case, removing non-Poisson components improves theAbstract: Previous studies have suggested that excess variations from single-photon counting systems used in luminescence dating may result in underestimation of errors and profoundly influence age models. In this study ten different photon counting systems have been investigated to explore this effect with a greater number of photomultiplier types and instrumental architectures. It is shown that radiation induced phosphorescence from F1 feldspar produces a controllable low-level light source whose local variance approximates Poisson expectations. However excess variation in dark counts was observed to varying extents from all systems. The excess variance is slightly anti-correlated with the age of the system, with older devices conforming more closely to Poisson behaviour. This observation does not seem to fit the hypothesis that enhanced levels of helium diffused into older tubes increase non-Poisson components. It was noted that a significant part of the non-Poisson behaviour was associated with multi-event pulse streams within time series. Work was also undertaken to develop mitigation methods for data analysis and to examine the implications for dating uncertainties in a test case. A Poisson-filtering algorithm was developed to identify and remove improbable multi-event streams. Application to data from signal-limited single grains of sediments from a Neolithic chambered tomb in Corsica has shown that, for this case, removing non-Poisson components improves the robustness of retained data, but has less influence on overall dating precision or accuracy. In signal limited applications use of this algorithm to remove one source of excess variation is beneficial. The algorithm and test data are appended to facilitate this. Highlights: New investigation of behaviour of 10 diverse photon counting systems. Low level phosphorescence close to Poisson counting statistics. Dark counts show non-Poisson counting statistics. New Poisson filter algorithm applied to low-sensitivity single grain data. Non-Poisson dark counts affect rejection criteria but not overall dating errors. … (more)
- Is Part Of:
- Radiation measurements. Volume 120(2019:Jan.)
- Journal:
- Radiation measurements
- Issue:
- Volume 120(2019:Jan.)
- Issue Display:
- Volume 120 (2019)
- Year:
- 2019
- Volume:
- 120
- Issue Sort Value:
- 2019-0120-0000-0000
- Page Start:
- 267
- Page End:
- 273
- Publication Date:
- 2018-12-15
- Subjects:
- Single photon counting -- Poisson variations -- Phosphorescence -- OSL single grain dating -- Poisson filtering
Nuclear emulsions -- Periodicals
Particle tracks (Nuclear physics) -- Periodicals
Thermoluminescence -- Periodicals
Cosmic rays -- Periodicals
Radiation -- Measurement -- Periodicals
Radiometry -- Periodicals
Radiation Monitoring -- Periodicals
Émulsions nucléaires -- Périodiques
Particules (Physique nucléaire) -- Traces -- Périodiques
Thermoluminescence -- Périodiques
Rayonnement cosmique -- Périodiques
Radiométrie -- Périodiques
539.77 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13504487 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-measurements/ ↗ - DOI:
- 10.1016/j.radmeas.2018.05.010 ↗
- Languages:
- English
- ISSNs:
- 1350-4487
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.973000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11593.xml