Agreement between spatiotemporal parameters from a photoelectric system with different filter settings and high-speed video analysis during running on a treadmill at comfortable velocity. (27th August 2019)
- Record Type:
- Journal Article
- Title:
- Agreement between spatiotemporal parameters from a photoelectric system with different filter settings and high-speed video analysis during running on a treadmill at comfortable velocity. (27th August 2019)
- Main Title:
- Agreement between spatiotemporal parameters from a photoelectric system with different filter settings and high-speed video analysis during running on a treadmill at comfortable velocity
- Authors:
- García-Pinillos, Felipe
Latorre-Román, Pedro Á.
Ramirez-Campillo, Rodrigo
Roche-Seruendo, Luis E. - Abstract:
- Abstract: The aim of this study was to determine the level of agreement between spatiotemporal gait characteristics from a photoelectric system with different filter settings and high-speed video analysis during running on a treadmill at comfortable velocity. Forty-nine runners performed a running protocol on a treadmill at comfortable velocity. Two systems were used to determine spatiotemporal parameters (i.e. contact time [CT], flight time [FT], step frequency [SF] and step length [SL]) during running: OptoGait system and high-speed video analysis at 1000 Hz. The collected data was re-filtered in the OptoGait software by using nine different settings (i.e. 0_0, 1_1, 2_2, 3_3, 3_4, 4_4, 4_5, 5_4 and 5_5), and compared to those obtained through video analysis. The Pearson correlation analysis revealed very large correlations (r > 0.9, p < 0.001) in CT, FT, SF and SL between both systems, regardless of the OptoGait's filter settings. The ICC reported an almost perfect association (ICC > 0.9) for both SL and SF regardless of the filter setting. However, large variations between filter settings according to the data from video analysis were reported in CT and FT (0_0, 1_1 and 2_2 filter settings obtained an association ICC > 0.9, whereas other filters obtained lower ICCs). Bland-Altman plots revealed small bias and error and no presence of heteroscedasticity of error for 1_1 setting. In conclusion, the filter setting for the OptoGait system should be considered to minimize theAbstract: The aim of this study was to determine the level of agreement between spatiotemporal gait characteristics from a photoelectric system with different filter settings and high-speed video analysis during running on a treadmill at comfortable velocity. Forty-nine runners performed a running protocol on a treadmill at comfortable velocity. Two systems were used to determine spatiotemporal parameters (i.e. contact time [CT], flight time [FT], step frequency [SF] and step length [SL]) during running: OptoGait system and high-speed video analysis at 1000 Hz. The collected data was re-filtered in the OptoGait software by using nine different settings (i.e. 0_0, 1_1, 2_2, 3_3, 3_4, 4_4, 4_5, 5_4 and 5_5), and compared to those obtained through video analysis. The Pearson correlation analysis revealed very large correlations (r > 0.9, p < 0.001) in CT, FT, SF and SL between both systems, regardless of the OptoGait's filter settings. The ICC reported an almost perfect association (ICC > 0.9) for both SL and SF regardless of the filter setting. However, large variations between filter settings according to the data from video analysis were reported in CT and FT (0_0, 1_1 and 2_2 filter settings obtained an association ICC > 0.9, whereas other filters obtained lower ICCs). Bland-Altman plots revealed small bias and error and no presence of heteroscedasticity of error for 1_1 setting. In conclusion, the filter setting for the OptoGait system should be considered to minimize the bias and error of spatiotemporal parameters measurement. For running on a treadmill, the 1_1 filter setting is recommended if gait parameters are to be compared to a high-speed video analysis (1000 Hz). … (more)
- Is Part Of:
- Journal of biomechanics. Volume 93(2019)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 93(2019)
- Issue Display:
- Volume 93, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 93
- Issue:
- 2019
- Issue Sort Value:
- 2019-0093-2019-0000
- Page Start:
- 213
- Page End:
- 219
- Publication Date:
- 2019-08-27
- Subjects:
- Data -- Filter -- Kinematics -- OptoGait -- Running
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2019.06.017 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11596.xml