Accurate Point-of-Care Detection of Ruptured Fetal Membranes: Improved Diagnostic Performance Characteristics with a Monoclonal/Polyclonal Immunoassay. (January 2016)
- Record Type:
- Journal Article
- Title:
- Accurate Point-of-Care Detection of Ruptured Fetal Membranes: Improved Diagnostic Performance Characteristics with a Monoclonal/Polyclonal Immunoassay. (January 2016)
- Main Title:
- Accurate Point-of-Care Detection of Ruptured Fetal Membranes: Improved Diagnostic Performance Characteristics with a Monoclonal/Polyclonal Immunoassay
- Authors:
- Rogers, Linda C.
Scott, Laurie
Block, Jon E. - Abstract:
- Objective: Accurate and timely diagnosis of rupture of membranes (ROM) is imperative to allow for gestational age-specific interventions. This study compared the diagnostic performance characteristics between two methods used for the detection of ROM as measured in the same patient. Methods: Vaginal secretions were evaluated using the conventional fern test as well as a point-of-care monoclonal/polyclonal immunoassay test (ROM Plus®) in 75 pregnant patients who presented to labor and delivery with complaints of leaking amniotic fluid. Both tests were compared to analytical confirmation of ROM using three external laboratory tests. Diagnostic performance characteristics were calculated including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy. Results: Diagnostic performance characteristics uniformly favored ROM detection using the immunoassay test compared to the fern test: sensitivity (100% vs. 77.8%), specificity (94.8% vs. 79.3%), PPV (75% vs. 36.8%), NPV (100% vs. 95.8%), and accuracy (95.5% vs. 79.1%). Conclusions: The point-of-care immunoassay test provides improved diagnostic accuracy for the detection of ROM compared to fern testing. It has the potential of improving patient management decisions, thereby minimizing serious complications and perinatal morbidity.
- Is Part Of:
- Clinical medicine insights. Volume 10(2016)
- Journal:
- Clinical medicine insights
- Issue:
- Volume 10(2016)
- Issue Display:
- Volume 10, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 10
- Issue:
- 2016
- Issue Sort Value:
- 2016-0010-2016-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-01
- Subjects:
- ROM Plus® -- premature rupture of membranes -- point-of-care immunoassay -- insulin-like growth factor binding protein-1 -- placental protein 12 -- alpha-fetoprotein -- fern test
Reproductive health -- Periodicals
Reproductive Medicine
Women's Health
Reproductive health
Electronic journals
Periodicals
Fulltext
Internet Resources
Periodicals
Periodicals
613.905 - Journal URLs:
- http://bibpurl.oclc.org/web/45491 ↗
http://www.la-press.com/clinical-medicine-reproductive-health-journal-j114 ↗
http://insights.sagepub.com/clinical-medicine-insights-reproductive-health-journal-j114 ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.4137/CMRH.S38386 ↗
- Languages:
- English
- ISSNs:
- 1179-5581
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11586.xml