Safety of Percutaneous Dilatational Tracheostomy During Veno-Venous Extracorporeal Membrane Oxygenation Support in Adults With Severe Respiratory Failure. Issue 2 (February 2019)
- Record Type:
- Journal Article
- Title:
- Safety of Percutaneous Dilatational Tracheostomy During Veno-Venous Extracorporeal Membrane Oxygenation Support in Adults With Severe Respiratory Failure. Issue 2 (February 2019)
- Main Title:
- Safety of Percutaneous Dilatational Tracheostomy During Veno-Venous Extracorporeal Membrane Oxygenation Support in Adults With Severe Respiratory Failure
- Authors:
- Dimopoulos, Stavros
Joyce, Holly
Camporota, Luigi
Glover, Guy
Ioannou, Nicholas
Langrish, Christopher J.
Retter, Andrew
Meadows, Christopher I. S.
Barrett, Nicholas A.
Tricklebank, Stephen - Abstract:
- Abstract : Objectives: To investigate the safety of percutaneous dilatational tracheostomy in severe respiratory failure patients during veno-venous extracorporeal membrane oxygenation support. Design: A single-center, retrospective, observational cohort study. Setting: Tertiary referral severe respiratory failure center, university teaching hospital. Patients: Severe respiratory failure patients consecutively admitted and supported with veno-venous extracorporeal membrane oxygenation between January 2010 and December 2015. Intervention: A bronchoscopy-guided percutaneous dilatational tracheostomy was performed in all cases. Measurements and Main Results: Sixty-five veno-venous extracorporeal membrane oxygenation patients (median [interquartile range] age, 47 yr [interquartile range, 35-59 yr]; 39 males; Acute Physiology and Chronic Health Evaluation-II score, 18 [interquartile range, 17-22] Sequential Organ Failure Assessment score, 10 [interquartile range, 7-16]) underwent percutaneous dilatational tracheostomy. Ten patients (15%) developed one or more major complications. Of these, seven (11%) had major bleeding, and three of these also required circuit change due to extracorporeal membrane oxygenation circuit dysfunction. Two more patients (3.1%) presented with isolated extracorporeal membrane oxygenation circuit dysfunction requiring circuit change, and one developed bilateral pneumothoraces (1.5%) requiring intercostal drain insertion. Patients who developedAbstract : Objectives: To investigate the safety of percutaneous dilatational tracheostomy in severe respiratory failure patients during veno-venous extracorporeal membrane oxygenation support. Design: A single-center, retrospective, observational cohort study. Setting: Tertiary referral severe respiratory failure center, university teaching hospital. Patients: Severe respiratory failure patients consecutively admitted and supported with veno-venous extracorporeal membrane oxygenation between January 2010 and December 2015. Intervention: A bronchoscopy-guided percutaneous dilatational tracheostomy was performed in all cases. Measurements and Main Results: Sixty-five veno-venous extracorporeal membrane oxygenation patients (median [interquartile range] age, 47 yr [interquartile range, 35-59 yr]; 39 males; Acute Physiology and Chronic Health Evaluation-II score, 18 [interquartile range, 17-22] Sequential Organ Failure Assessment score, 10 [interquartile range, 7-16]) underwent percutaneous dilatational tracheostomy. Ten patients (15%) developed one or more major complications. Of these, seven (11%) had major bleeding, and three of these also required circuit change due to extracorporeal membrane oxygenation circuit dysfunction. Two more patients (3.1%) presented with isolated extracorporeal membrane oxygenation circuit dysfunction requiring circuit change, and one developed bilateral pneumothoraces (1.5%) requiring intercostal drain insertion. Patients who developed complications had significantly lower extracorporeal membrane oxygenation postoxygenator PO2 prior to percutaneous dilatational tracheostomy (45.8 kPa [interquartile range, 36.9–56.5 kPa] vs 57.9 kPa [interquartile range, 45.1–64.2 kPa]; p = 0.019]. On multivariate analysis, including demographic, clinical, biochemical, hematologic variables, and extracorporeal membrane oxygenation circuit functional variables, extracorporeal membrane oxygenation postoxygenator PO2 was the only independent variable associated with major complications following percutaneous dilatational tracheostomy (beta = –0.09; odds ratio, 0.9; 95% CI, 0.84–0.99; p = 0.03). Conclusions: Percutaneous dilatational tracheostomy is associated with a considerable complication rate in veno-venous extracorporeal membrane oxygenation patients. Preprocedure circuit performance as indicated by extracorporeal membrane oxygenation postoxygenator PO2 is an independent predictor of major complications following percutaneous dilatational tracheostomy. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Critical care medicine. Volume 47:Issue 2(2019)
- Journal:
- Critical care medicine
- Issue:
- Volume 47:Issue 2(2019)
- Issue Display:
- Volume 47, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 47
- Issue:
- 2
- Issue Sort Value:
- 2019-0047-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-02
- Subjects:
- extracorporeal membrane oxygenation -- mechanical ventilation -- safety -- severe respiratory failure -- tracheostomy -- weaning
Critical care medicine -- Periodicals
Soins intensifs -- Périodiques
616.028 - Journal URLs:
- http://journals.lww.com/ccmjournal/Pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/CCM.0000000000003515 ↗
- Languages:
- English
- ISSNs:
- 0090-3493
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3487.451000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11600.xml