Lateralized periodic discharges frequency correlates with glucose metabolism. (12th February 2019)
- Record Type:
- Journal Article
- Title:
- Lateralized periodic discharges frequency correlates with glucose metabolism. (12th February 2019)
- Main Title:
- Lateralized periodic discharges frequency correlates with glucose metabolism
- Authors:
- Subramaniam, Thanujaa
Jain, Aditya
Hall, Lance T.
Cole, Andrew J.
Westover, M. Brandon
Rosenthal, Eric S.
Struck, Aaron F. - Abstract:
- Abstract : Objective: To investigate the correlation between characteristics of lateralized periodic discharges (LPDs) and glucose metabolism measured by 18 F-fluorodeoxyglucose (FDG)–PET. Methods: We retrospectively reviewed medical records to identify patients who underwent FDG-PET during EEG monitoring with LPDs present during the FDG uptake period. Two blinded board-certified neurophysiologists independently interpreted EEGs. FDG uptake was measured using standardized uptake value (SUV). Structural images were fused with PET images to aid with localization of SUV. Two PET readers independently measured maximum SUV. Relative SUV values were obtained by normalization of the maximum SUV to the SUV of pons (SUVRpons). LPD frequency was analyzed both as a categorical variable and as a continuous measure. Other secondary variables included duration, amplitude, presence of structural lesion, and "plus" EEG features such as rhythmic or fast sharp activity. Results: Nine patients were identified and 7 had a structural etiology for LPDs. Analysis using frequency as a categorical variable and continuous variable showed an association between increased LPD frequency and increased ipsilateral SUVRpons ( p = 0.02). Metabolism associated with LPDs (0.5 Hz as a baseline) increased by a median of 100% at 1 Hz and for frequencies >1 Hz increased by a median of 309%. There were no statistically significant differences in SUVRpons for other factors including duration ( p = 0.10), amplitudeAbstract : Objective: To investigate the correlation between characteristics of lateralized periodic discharges (LPDs) and glucose metabolism measured by 18 F-fluorodeoxyglucose (FDG)–PET. Methods: We retrospectively reviewed medical records to identify patients who underwent FDG-PET during EEG monitoring with LPDs present during the FDG uptake period. Two blinded board-certified neurophysiologists independently interpreted EEGs. FDG uptake was measured using standardized uptake value (SUV). Structural images were fused with PET images to aid with localization of SUV. Two PET readers independently measured maximum SUV. Relative SUV values were obtained by normalization of the maximum SUV to the SUV of pons (SUVRpons). LPD frequency was analyzed both as a categorical variable and as a continuous measure. Other secondary variables included duration, amplitude, presence of structural lesion, and "plus" EEG features such as rhythmic or fast sharp activity. Results: Nine patients were identified and 7 had a structural etiology for LPDs. Analysis using frequency as a categorical variable and continuous variable showed an association between increased LPD frequency and increased ipsilateral SUVRpons ( p = 0.02). Metabolism associated with LPDs (0.5 Hz as a baseline) increased by a median of 100% at 1 Hz and for frequencies >1 Hz increased by a median of 309%. There were no statistically significant differences in SUVRpons for other factors including duration ( p = 0.10), amplitude ( p = 0.80), structural etiology ( p = 0.55), or "plus" features such as rhythmic or fast sharp activity ( p = 0.84). Conclusions: Metabolic activity increases monotonically with LPD frequency. LPD frequency should be a measure of interest when developing neuroprotection strategies in critical neurologic illness. … (more)
- Is Part Of:
- Neurology. Volume 92:Number 7(2019)
- Journal:
- Neurology
- Issue:
- Volume 92:Number 7(2019)
- Issue Display:
- Volume 92, Issue 7 (2019)
- Year:
- 2019
- Volume:
- 92
- Issue:
- 7
- Issue Sort Value:
- 2019-0092-0007-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-02-12
- Subjects:
- Neurology -- Periodicals
Neurology -- Periodicals
Neurologie -- Périodiques
616.8 - Journal URLs:
- http://www.mdconsult.com/public/search?search_type=journal&j_sort=pub_date&j_issn=0028-3878 ↗
http://www.mdconsult.com/about/journallist/192093418-5/about0nz0.html ↗
http://www.neurology.org ↗
http://journals.lww.com ↗ - DOI:
- 10.1212/WNL.0000000000006903 ↗
- Languages:
- English
- ISSNs:
- 0028-3878
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.500000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11580.xml