Monitoring haemodynamic response to fluid-challenge in ICU: comparison of pressure recording analytical method and oesophageal Doppler. Issue 2 (February 2019)
- Record Type:
- Journal Article
- Title:
- Monitoring haemodynamic response to fluid-challenge in ICU: comparison of pressure recording analytical method and oesophageal Doppler. Issue 2 (February 2019)
- Main Title:
- Monitoring haemodynamic response to fluid-challenge in ICU
- Authors:
- Barthélémy, Romain
Neuschwander, Arthur
Dramé, Fatou
Redouté, Maximilien
Ditchi, David
Stern, Jules
Mebazaa, Alexandre
Pirracchio, Romain
Chousterman, Benjamin G. - Abstract:
- Abstract : BACKGROUND: The ability of the pressure recording analytical method (PRAM) in tracking change in cardiac output (ΔCO) after a fluid challenge in ICU needs to be evaluated with the most contemporary comparison methods recommended by experts. OBJECTIVE: Our objective was to report the trending ability of PRAM in tracking ΔCO after a fluid challenge in ICU and to compare this with oesophageal Doppler monitoring (ODM). DESIGN: Prospective, observational study. SETTING: Hôpital Lariboisière and Hôpital Européen George Pompidou, Paris, France, from April 2016 to December 2017. PATIENTS: Critically ill patients admitted to ICU with monitoring of CO monitored by ODM and invasive arterial pressure. INTERVENTION: ΔCO after fluid challenge was simultaneously registered with ODM and PRAM connected to the arterial line. MAIN OUTCOME MEASURE: Polar statistics (mean angular bias, radial limits of agreement and polar concordance rate) and clinical concordance evaluation (error grid and clinical concordance rate). Predictors of bias were determined. RESULTS: Sixty-eight fluid challenge were administered in 49 patients. At the time of fluid challenge, almost all were mechanically ventilated (99%), with 85% receiving norepinephrine. Admission diagnosis was septic shock in 70% of patients. Patients had a Sequential Organ Failure Assessment score of 10 [7 to 12] and a median Simplified Acute Physiology Score II of 61 [49 to 69]. Relative ΔCO bias was 7.8° (6.3°) with radial limits ofAbstract : BACKGROUND: The ability of the pressure recording analytical method (PRAM) in tracking change in cardiac output (ΔCO) after a fluid challenge in ICU needs to be evaluated with the most contemporary comparison methods recommended by experts. OBJECTIVE: Our objective was to report the trending ability of PRAM in tracking ΔCO after a fluid challenge in ICU and to compare this with oesophageal Doppler monitoring (ODM). DESIGN: Prospective, observational study. SETTING: Hôpital Lariboisière and Hôpital Européen George Pompidou, Paris, France, from April 2016 to December 2017. PATIENTS: Critically ill patients admitted to ICU with monitoring of CO monitored by ODM and invasive arterial pressure. INTERVENTION: ΔCO after fluid challenge was simultaneously registered with ODM and PRAM connected to the arterial line. MAIN OUTCOME MEASURE: Polar statistics (mean angular bias, radial limits of agreement and polar concordance rate) and clinical concordance evaluation (error grid and clinical concordance rate). Predictors of bias were determined. RESULTS: Sixty-eight fluid challenge were administered in 49 patients. At the time of fluid challenge, almost all were mechanically ventilated (99%), with 85% receiving norepinephrine. Admission diagnosis was septic shock in 70% of patients. Patients had a Sequential Organ Failure Assessment score of 10 [7 to 12] and a median Simplified Acute Physiology Score II of 61 [49 to 69]. Relative ΔCO bias was 7.8° (6.3°) with radial limits of agreement of ±41.7°, polar concordance rate 80% and clinical concordance rate 74%. ΔCO bias was associated with baseline bias ( P = 0.007). Baseline bias was associated with radial location of the arterial line ( P = 0.03). CONCLUSION: When compared with ODM, PRAM has insufficient performance to track ΔCO induced by fluid challenge in ICU patients. Baseline bias is an independent predictor of trending bias. TRIAL REGISTRATION: IRB 00010254-2016-033. Abstract : Supplemental Digital Content is available in the text … (more)
- Is Part Of:
- European journal of anaesthesiology. Volume 36:Issue 2(2019:Feb.)
- Journal:
- European journal of anaesthesiology
- Issue:
- Volume 36:Issue 2(2019:Feb.)
- Issue Display:
- Volume 36, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 36
- Issue:
- 2
- Issue Sort Value:
- 2019-0036-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-02
- Subjects:
- Anesthesiology -- Periodicals
Anesthesiology -- Periodicals
Anesthésiologie -- Périodiques
Anesthesiology
Periodicals
Electronic journals
617.96 - Journal URLs:
- http://journals.lww.com/ejanaesthesiology/pages/default.aspx ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2346/issues ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=eja ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00003643-000000000-00000 ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0265-0215 ↗ - DOI:
- 10.1097/EJA.0000000000000924 ↗
- Languages:
- English
- ISSNs:
- 0265-0215
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.722200
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11574.xml