First comparative results about the direct effect of traditional cigarette and e-cigarette smoking on lung alveolocapillary membrane using dynamic ventilation scintigraphy. Issue 2 (February 2019)
- Record Type:
- Journal Article
- Title:
- First comparative results about the direct effect of traditional cigarette and e-cigarette smoking on lung alveolocapillary membrane using dynamic ventilation scintigraphy. Issue 2 (February 2019)
- Main Title:
- First comparative results about the direct effect of traditional cigarette and e-cigarette smoking on lung alveolocapillary membrane using dynamic ventilation scintigraphy
- Authors:
- Barna, Sandor
Rózsa, David
Varga, Jozsef
Fodor, Andrea
Szilasi, Maria
Galuska, Laszlo
Garai, Ildiko - Abstract:
- Abstract : Introduction: Dynamic inhalation scintigraphy (DIS) with technetium-99m-diethylenetriamine-pentaacetate aerosol is a useful nuclear medicine procedure for staging and monitoring the damage of alveolocapillary membrane. The e-cigarette is a new popular smoking device producing vapor from the nicotine solution. Many studies have shown that e-cigarettes appear to be safer than smoking, but there are still debates to what extent e-cigarettes are less harmful than smoking. In this prospective, self-controlled study, we compared DIS results among volunteers smoking an e-cigarette and their results after they returned to traditional cigarette smoking for a week. Participants and methods: We included 24 healthy volunteers into this study who regularly used e-cigarette containing at least 10 mg nicotine/ml. We performed baseline DIS study in volunteers with e-cigarette smoking and then we asked them to return to traditional cigarette smoking for a week. Conventional respiration tests were also measured. We statistically analyzed the effect of traditional cigarette on clinical parameters and pulmonary clearance of the radiopharmacon. Results: There was no significant change in the parameters of peak expiratory flow rate and Tiffeneau-Pinelli index respiration tests; forced vital capacity and forced expiratory volume in 1 s slightly decreased ( P <0.05), whereas the exhaled CO and COHb levels were significantly higher at traditional cigarette use ( P <0.0001), and increasedAbstract : Introduction: Dynamic inhalation scintigraphy (DIS) with technetium-99m-diethylenetriamine-pentaacetate aerosol is a useful nuclear medicine procedure for staging and monitoring the damage of alveolocapillary membrane. The e-cigarette is a new popular smoking device producing vapor from the nicotine solution. Many studies have shown that e-cigarettes appear to be safer than smoking, but there are still debates to what extent e-cigarettes are less harmful than smoking. In this prospective, self-controlled study, we compared DIS results among volunteers smoking an e-cigarette and their results after they returned to traditional cigarette smoking for a week. Participants and methods: We included 24 healthy volunteers into this study who regularly used e-cigarette containing at least 10 mg nicotine/ml. We performed baseline DIS study in volunteers with e-cigarette smoking and then we asked them to return to traditional cigarette smoking for a week. Conventional respiration tests were also measured. We statistically analyzed the effect of traditional cigarette on clinical parameters and pulmonary clearance of the radiopharmacon. Results: There was no significant change in the parameters of peak expiratory flow rate and Tiffeneau-Pinelli index respiration tests; forced vital capacity and forced expiratory volume in 1 s slightly decreased ( P <0.05), whereas the exhaled CO and COHb levels were significantly higher at traditional cigarette use ( P <0.0001), and increased in every case. The pulmonary clearance was significantly faster at traditional cigarette smoking compared with e-cigarette use ( P <0.0001). Conclusion: On the basis of our results, we suppose that e-cigarette smoking is less harmful to the lung function than a traditional cigarette, and it can be recommended to heavy smokers who are unable to stop smoking. … (more)
- Is Part Of:
- Nuclear medicine communications. Volume 40:Issue 2(2019:Feb.)
- Journal:
- Nuclear medicine communications
- Issue:
- Volume 40:Issue 2(2019:Feb.)
- Issue Display:
- Volume 40, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 40
- Issue:
- 2
- Issue Sort Value:
- 2019-0040-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-02
- Subjects:
- e-cigarette -- lung function -- nicotine
Nuclear medicine -- Periodicals
616.07575 - Journal URLs:
- http://journals.lww.com/nuclearmedicinecomm/pages/default.aspx ↗
http://journals.lww.com/pages/default.aspx ↗
http://www.lww.com/Product/0143-3636 ↗ - DOI:
- 10.1097/MNM.0000000000000957 ↗
- Languages:
- English
- ISSNs:
- 0143-3636
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6180.923000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11573.xml